Tender Details
Particulars | Details |
---|---|
Title |
Replacement Of Damaged/Degraded 1500mm Dia Common Manifold, 1000mm Dia Air Vessels And 600mm Dia Delivery Lines Of Pumps Duly Laying New Ms Pipes Of 1500mm, 1000mm And 600mm At Phase Ii Pump House Under Eam Cell I, Kalabgoor, Td Ii, Patancheru
|
Description |
Replacement Of Damaged/Degraded 1500mm Dia Common Manifold, 1000mm Dia Air Vessels And 600mm Dia Delivery Lines Of Pumps Duly Laying New Ms Pipes Of 1500mm,1000mm And 600mm At Phase Ii Pump House Under Eam Cell I, Kalabgoor Transmission Division No.Ii, Patancheru
|
Organisation | Information Technology Electronics and Communication Department Telangana | State Govt. and UT |
Tender Id |
AAAAAAAAAA Login to view |
Reference Number |
AAAAAAAAAA Login to view |
Tender Fee | 10729 |
EMD | 3.03 Lakh |
Tender Value | |
Place | TS |
Link |
AAAAAAAAAA Login to view |
Start Date | April 22, 2025 17:00 |
End Date |
29/04/2025 ( 5 days left ) Search Similar tenders? |
Join for More Relevant Opportunities |
Replacement of damaged/degraded 1500mm dia common manifold, 1000mm dia air vessels and 600mm dia delivery lines of pumps duly laying new ms pipes of 1500mm, 1000mm and 600mm at phase-ii pump house under eam cell-i, kalabgoor, td-ii, patancheru
Replacement of damaged/degraded 1500mm dia common manifold, 1000mm dia air vessels and 600mm dia delivery lines of pumps duly laying new ms pipes of 1500mm,1000mm and 600mm at phase-ii pump house under eam cell-i, kalabgoor transmission division no.ii, patancheru
Read moreProviding arrangements to draw surface water from himayathsagar to 6 mgd mir-alam filter beds by fixing of 30 hp and 40 hp submersible pump sets, ms pipes, rubber flexible hose pipes, valves, electrical panel board, cables etc., at himayathsagar earth dam under eam section, sd-ii, td-i, himayathsagar
Providing arrangements to draw surface water from himayathsagar to 6 mgd mir-alam filter beds by fixing of 30 and 40 hp submersible pump sets, ms pipes, rubber flexible hose pipes, valves, electrical panel board, cables etc., at himayathsagar earth dam, under eam section, sd-ii, td-i, himayathsagar
Read moreRewinding, reconditioning and replacements of spares for 850 kw, 6.6 kv, ht motor at peddapur ph-iv, pumping station, replacements spares for existing pumps at ph-iv, peddapur including dismantling, loading, transportation, unloading, erection, testing and commissioning of and ht motor mwss, eam cell-ii, peddapur under td-ii, patancheru
Rewinding, reconditioning and replacements of spares for 850kw, 6.6kv, ht motor at peddapur phase-iv, pumping station, replacements of spares for existing pumps at phase-iv, peddapur including dismantling, loading, transportation, unloading, erection, testing and commissioning of and ht motor under mwss, eam cell-ii, peddapur, transmission division no-ii, patancheru
Read moreSupply, delivery and laying of filter sand media,grit and pebbles including removing of old media grit ac pipes, plastering to internal walls, epoxy painting to the internal surfaces of the filter beds, relaying of new sand media , grit and pebbles with replacement of damaged top/bottom and side ms channels with new ms channels, replacement of lateral ac/cpvc etc., for filter beds nos. 1,2,3,4,5 and 9 plastering and water proofing to roof top of wtp building at ph-i, wtp rajampet,sd-i, td-ii
Supply, delivery and laying of filter sand media, grit and pebbles including removing of old media grit ac pipes, plastering to internal walls, epoxy painting to the internal surfaces of the filter beds, relaying of new sand media, grit and pebbles with replacement of damaged top/bottom and side ms channels with new ms channels, replacement of lateral ac/cpvc etc., for filter beds nos 1,2,3,4,5 and 9 plastering and water proofing to roof top of wtp building at phase-i, wtp rajampet under sub-division no.i, kalabgoor, transmission division no.ii, patancheru
Read moreRemoval and replacement of damaged portion of 6/ 4/ 3 inches dia ms and gi pipe for firefighting and water supply at crushing and reclaim section of phase-i and ii chp dudhichua
Removal and replacement of damaged portion of 6/ 4/ 3 inches dia ms and gi pipe for firefighting and water supply at crushing and reclaim section of phase-i and ii chp dudhichua
Read moreRefurbishment and upgradation of existing old system including supply, delivery, erection, testing and commissioning of 3.3kv 503.0 kw, ht motors and mandatory spares for 3.3kv hsc pump sets at rajampet patancheru 6.6kv hsc pumpsets at phase-ii, iii and iv at kalabgoor, peddapur campus and 6.6kv vertical pump sets at intake well, kalabgoor under td-ii, patancheru
Refurbishment and up-gradation of existing old system including supply,delivery,erection,testing and commissioning of 3.3 kv 503.0 kw, ht motors and mandatory spares for 3.3 kv hsc pump sets at rajampet patancheru, 6.6 kv hsc pump sets at phase-ii,iii and iv of kalabgoor,peddapur campus and 6.6kv vertical pump sets at intake well, kalabgoor etc., under manjira drinking water supply scheme of transmission division no.ii, patancheru
Read moreShifting of 200/150mm dia double kinetic air valves existing on 1500mm dia ms gravity main of kdwsp phase-iii ring main-ii and 800mm dia psc/ms of pocharam pipeline for facilitating development road widening work at nfc circle by ghmc under moula-ali section, sd-iii, td-iii, sahebnagar
Shifting of 200/150mm dia double kinetic air valves existing on 1500mm dia ms gravity main of kdwsp phase-iii ring main-ii and 800mm dia psc/ms of pocharam pipe line for facilitating development road widening work at nfc circle by ghmc under moula-ali section, sd-iii, trans.div.iii, sahebnagar.
Read moreReplacement of 1000mm dia ph-i psc pipes of mwss pumping main from ch.no.753 to 765 with ms pipe in lining out coating pipe line under ph-i ph-ii pipeline section, sd-i, td-ii, patancheru
Replacement of 1000 mm dia ph-i psc pipes of mwss pumping main from ch.no.753 to 765 with ms pipe in lining out coating pipe line under ph-i and ph-ii pipeline section,sub-division no.i, transmission division no.ii, patancheru
Read moreSupply, delivery of 500mm dia pn 25/class 150 rated, non- valves and 500mm dia pn-16 rated, butterfly valves in place damaged valves and laying of 300mm x 50mm x 2mm thick gi ladder type cable tray for 300 sq.mm ht cable for spare feeder from substationto ph-iii, pump house at peddapur ph-iii and iv using pumping stations along with accessories etc under mwss, ph-iii and iv under td-ii, patancheru.
Supply and delivery of 500mm dia pn 25/class 150 rated, non- valves and 500mm dia pn-16 rated, butterfly valves in place damaged valves and laying of 300mm x 50mmx2mm thick gi ladder type cable tray for 300sq.mm ht cable for spare feeder from substation to phase-iii, pump house at peddapur phase-iii and iv pumping stations along with accessories etc, under manjira drinking water supply scheme, phase-iii and iv under transmission division no.ii, patancheru
Read moreReplacement of 1000mm dia ph-i psc pipes of mwss pumping main between ch.no.776 to 790 with ms pipe inlining out coating pipe line under ph-i ph-ii pipeline section, sd-i, td-ii, patancheru
Replacement of 1000 mm dia ph-i psc pipes of mwss pumping main between ch.no.776 to 790 with ms pipe in lining out coating pipe line under ph-i ph-ii pipeline section,sub-division no.i, transmission division no.ii, patancheru
Read moreof your Industry type