Tender Details

About Tender

🚂 Procurement Opportunity: Lead Apron Stands For Medical Safety 🛡️ The Ministry Of Railways, Under The Central Government, Invites Tenders For The Supply Of Lead Apron Stands Capable Of Accommodating 10 Lead Aprons. The Technical Specifications For The Stands Are As Follows: 1. Mobile And Sturdy Design. 2. Stainless Steel Hangers For Aprons, With Stainless Steel Or Stainless Free Material, Ensuring Adequate Load Bearing Capacity. 3. Equipped With A Braking Mechanism For Easy Movement. 4. Compliance With Icmed 13485: Indian Certification For Medical Devices. 5. The Manufacturer Must Hold Iso 13485 And Iso 9001 Certifications. Bid Submission Deadline: 09/05/2024, 2:00 Pm ⏳ Interested Bidders Should Submit Detailed Proposals, Including Technical Specifications, Pricing, And Delivery Schedules, In Accordance With The Tender Document. Keywords: Lead Apron Stands, Medical Equipment, Ministry Of Railways, Central Government, Tender, Procurement, Iso Certified, Medical Safety
Particulars Details
Title
Lead Apron Stand For 10 Aprons. Technical Specification: 1. It Should Be Mobile And Sturdy And Should Accommodate 10 Lead Aprons. 2. The Hangers For Apron Should Be Of Stainless Steel. Hanger Material Should Be Stainless Steel Or Stain Free Material And Adequate Load Bearing Capacity. 3. It Should Be Convenient To Move With Braking Mechanism. 4. Product Should Be Having Icmed13485: Indian Certification For Medical Devices. 5. Manufacturer Should Be Iso 13485 And Iso 9001 Certified.
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 106332207
Reference
Number
HB245692A
Tender Fee 0
EMD 0
Tender Value -
Place Kolkata
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/052024/106332207/viewNitPdf_4554928.pdf

Start Date April 30, 2024 18:54
End Date
Expired 09/05/2024

Expired 891 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Floor end profile,l=2000mm, as per drawing: lw41112, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation.the item should be packed with adequate strength.

Floor end profile,l=2000mm, as per drawing: lw41112, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation.the item should be packed with adequate strength.

Read more
Carbide sludge containing minimum 50 cao (on dry basis) . it should be free from grits, stone, lumps

Carbide sludge containing minimum 50 cao (on dry basis) . it should be free from grits, stone, lumps

Read more
Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)

Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)

Read more
Chlorine tablets for use in ir-drdo bio-toilets confirming to rcf specification mdts-14274 rev-00. technical requirements: 1. the tablet size should be 78 mm diameter and weight should be of approximately 200 g. 2. the tablet should have active molecule of 3, 5 di-chloro-isocyanuric-acid. 3. it should have effective chlorine of >= 50 percent chlorine. 4. the tablet should have formulated for sustained release (should last for at least 21 days in tap water). 5. moisture content should be

Chlorine tablets for use in ir-drdo bio-toilets confirming to rcf specification mdts-14274 rev-00. technical requirements: 1. the tablet size should be 78 mm diameter and weight should be of approximately 200 g. 2. the tablet should have active molecule of 3, 5 di-chloro-isocyanuric-acid. 3. it should have effective chlorine of >= 50 percent chlorine. 4. the tablet should have formulated for sustained release (should last for at least 21 days in tap water). 5. moisture content should be

Read more
Pacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b

Pacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b

Read more
Nyloc nut m20 high tensile, as per drawing: is:7002-1991/din982, 10, coating as per mdts-057, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage, if any, shall be at the cost of supplier. as per drawing no: lw05004 alt d , item no-57

Nyloc nut m20 high tensile, as per drawing: is:7002-1991/din982, 10, coating as per mdts-057, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage, if any, shall be at the cost of supplier. as per drawing no: lw05004 alt d , item no-57

Read more
Hq_med_sur_[ph.no.272005] cotton bandage cloth non sterilized. the cloth should be woven in plain weave with well formed selvedge and free from filling, stitching or dressing material defects. it should be bleached to good white as per is.863:1988. width of 100 cm, supply in metres.

Hq_med_sur_[ph.no.272005] cotton bandage cloth non sterilized. the cloth should be woven in plain weave with well formed selvedge and free from filling, stitching or dressing material defects. it should be bleached to good white as per is.863:1988. width of 100 cm, supply in metres.

Read more
Intubating catheter/bougie 14 french 70 cm long - (1) it should facilitate endotracheal intubation in patients when visualisation of the glottis is inadequate. (2). introducer should be a 14 french 70 cm long radio opaque catheter for adults (3). the tip should be blunt and angled to assist in proper placement beyond the vocal cords and to minimise trauma to internal structures. (4). should have 2 removable adapters to permit ventilation. one with a 15mm adapter to connect to ventilating circu

Intubating catheter/bougie 14 french 70 cm long - (1) it should facilitate endotracheal intubation in patients when visualisation of the glottis is inadequate. (2). introducer should be a 14 french 70 cm long radio opaque catheter for adults (3). the tip should be blunt and angled to assist in proper placement beyond the vocal cords and to minimise trauma to internal structures. (4). should have 2 removable adapters to permit ventilation. one with a 15mm adapter to connect to ventilating circu

Read more
Disposable rotatable rat tooth forceps should have 1. rat tooth / alligator jaw with opening width of 3.8 mm to 7.2 mm and compatible with 2.8 mm instrument channel. 2. firm grip & easy movould be available with rotatable graspers. 3. shaft length more than 160cm and jaw opening from 11.3mm to 14.9mm. 4.should be made of medical grade stainless steel with ptfe

Disposable rotatable rat tooth forceps should have 1. rat tooth / alligator jaw with opening width of 3.8 mm to 7.2 mm and compatible with 2.8 mm instrument channel. 2. firm grip & easy movould be available with rotatable graspers. 3. shaft length more than 160cm and jaw opening from 11.3mm to 14.9mm. 4.should be made of medical grade stainless steel with ptfe

Read more
One piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.

One piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.

Read more
Click Here to Download Dockets