Tender Details

Particulars Details
Title
Air, Noise, Water And Stack Monitoring As Per Pcb & Calibration Of Pressure Gauges, Pv Valve, Oti/W
Description
Organisation INDIAN OIL CORPORATION LIMITED | Ministry of Petroleum and Natural Gas
Tender Id GEM/2024/B/5256109
Reference
Number
-
Tender Fee -
EMD -
Tender Value -
Place
Link
View Original Tender Notice

https://bidplus.gem.gov.in/all-bids

Start Date August 12, 2024 20:32
End Date
Expired 02/09/2024

Expired 771 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Award of Contract & Bid Results

Awarded Contractor / Winner

NITYA LABORATORIES

Contract Value

1006634.4

Tender Status: active
Additional Information: Average Turn Over of Last 3 Years: 2 Lakhs Experience with Gov. Required: Years
Buyer Name: Suraj Tyagi
Ministry: Ministry Of Petroleum And Natural Gas
Department: Indian Oil Corporation Limited
Organisation: Marketing Division

Technical Evaluation Results

S.No. Seller Name Offered Item Participated On MSE/MII Status Status
1 ENVIRONMENT & SAFETY SOLUTION Make : Environmental Services Model : Air, Noise, Water and Stack monitoring as per PCB Title : Air, Noise, Water and Stack monitoring as per PCB & calibration of Pressure Gauges, PV valve, OTI/WTI 26-08-2024 17:07:31 MII Disqualified
2 ENVIRONMENT POLLUTION ANALYSIS LAB Make : na Model : Air, Noise, Water And Stack Monitoring As Per PCB Title : Air, Noise, Water And Stack Monitoring As Per PCB & Calibration Of Pressure Gauges, PV Valve, OTI/WT 02-09-2024 13:55:01 MII Qualified
3 NEW POWER TRACKS Make : Environmental Services Model : Air, Noise, Water and Stack monitoring as per PCB Title : Air, Noise, Water and Stack monitoring as per PCB & calibration of Pressure Gauges, PV valve, OTI/WTI 28-08-2024 20:16:02 MII Disqualified
4 NITYA LABORATORIES Make : NITYA LABORATORIES Model : Nitya Lab Title : Air, Noise, Water and Stack monitoring as per PCB & calibration of Pressure Gauges, PV valve, OTI/WTI 02-09-2024 12:36:08 MII Qualified

Financial Evaluation Results

S.No. Seller Name Offered Item Total Price Rank
1 ENVIRONMENT POLLUTION ANALYSIS LAB (MII) Item Categories : Air, Noise, Water and Stack monitoring as per PCB & calibration of Pressure Gauges, PV valve, OTI/W 1370404.80 Disqualified
2 NITYA LABORATORIES(MII) Item Categories : Air, Noise, Water and Stack monitoring as per PCB & calibration of Pressure Gauges, PV valve, OTI/W 1006634.40 L1

Ordered Items & Contract Pricing

Product Brand Model Ordered Quantity Price
Air, Noise, Water and Stack monitoring as per PCB & calibration of Pressure Gauges, PV valve, OTI/WTI NITYA LABORATORIES Nitya Lab 1 ₹ 1006634.400
Similar Tenders
Out sourcing of nd testing, hydraulic pressure testing, calibration of pressure gauge and relief valve and shell thickness measurement of air reciever tanks of hemm working at kkocp for period of 3 years.

Out sourcing of nd testing, hydraulic pressure testing, calibration of pressure gauge and relief valve and shell thickness measurement of air reciever tanks of hemm working at kkocp for period of 3 years.

Read more
Calibration services - safety relief valve as per as per sor sl no1 schedule of rates under section vii of atc as per approved atc document as per approved atc document as per approved atc document,calibration services - pressure safety valve as per sor sl no 2 schedule of rates under section vii of atc as per approved atc document as per approved atc document as per approved atc document,calibration services - pressure safety valve, leser, (set pressure 40 kg per cm2) as per sor sl no 3 schedule of rates under section vii of atc as per approved atc document as per approved atc document as per approved atc document,calibration services - creep relief valve as per sor sl no 4 schedule of rates under section vii of atc as per approved atc document as per approved atc document as per approved atc document,calibration services - creep relief valve (set pressure 23 kg per cm2) as per sor sl no 5 schedule of rates under section vii of atc as per approved atc document as per approved atc document as

Calibration services - safety relief valve as per as per sor sl no1 schedule of rates under section vii of atc as per approved atc document as per approved atc document as per approved atc document,calibration services - pressure safety valve as per sor sl no 2 schedule of rates under section vii of atc as per approved atc document as per approved atc document as per approved atc document,calibration services - pressure safety valve, leser, (set pressure 40 kg per cm2) as per sor sl no 3 schedule of rates under section vii of atc as per approved atc document as per approved atc document as per approved atc document,calibration services - creep relief valve as per sor sl no 4 schedule of rates under section vii of atc as per approved atc document as per approved atc document as per approved atc document,calibration services - creep relief valve (set pressure 23 kg per cm2) as per sor sl no 5 schedule of rates under section vii of atc as per approved atc document as per approved atc document as

Read more
Custom bid for services - lumpsum amount incl all charges and gst for part a for deployment of contract labour for monitoring of environment parameters for 02 years on pre disclosed rates as per scc and sow,custom bid for services - lumpsum amount incl all charges and gst for part b for ambient air monitoring where one lumpsum equals to 432 ea as per scc and sow of tender document,custom bid for services - lumpsum amount incl all charges and gst for part b for stack monitoring where one lumpsum equals to 432 ea as per scc and sow of tender document,custom bid for services - lumpsum amount incl all charges and gst for part b for noise monitoring in work zone where one lumpsum equals to 552 ea as per scc and sow of tender document,custom bid for services - lumpsum amount incl all charges and gst for part b for co voc benzene and h2s in work zone where one lumpsum equals to 552 ea as per scc and sow of tender document,custom bid for services - lumpsum amount incl all charges and gst for part b for co2 monitoring

Custom bid for services - lumpsum amount incl all charges and gst for part a for deployment of contract labour for monitoring of environment parameters for 02 years on pre disclosed rates as per scc and sow,custom bid for services - lumpsum amount incl all charges and gst for part b for ambient air monitoring where one lumpsum equals to 432 ea as per scc and sow of tender document,custom bid for services - lumpsum amount incl all charges and gst for part b for stack monitoring where one lumpsum equals to 432 ea as per scc and sow of tender document,custom bid for services - lumpsum amount incl all charges and gst for part b for noise monitoring in work zone where one lumpsum equals to 552 ea as per scc and sow of tender document,custom bid for services - lumpsum amount incl all charges and gst for part b for co voc benzene and h2s in work zone where one lumpsum equals to 552 ea as per scc and sow of tender document,custom bid for services - lumpsum amount incl all charges and gst for part b for co2 monitoring

Read more
Calibration and repair of moisture meter,test cup,spur gear,bevel gear,guide nut,insulation disk,thrust bearing,bevel pinion,micro controller,electronic switch,com. pcb,com. meggar box,temperature sensor,i.c. regulator 7805,timer i.c. 7555,i.c 4051,i.c 7447,eprom,f.n.d. board,ic 7135,complete body universal,bracket,spur pinion bigsmall,40 pin header set,pinion brush,lead screw,volume cup a,volume cup b,volume cup c,allen key,battery compartment,adaptor,connector leads 12 pin,connector leads 2 3 pins,relay,segment i.c.,i.c. 7600,switching transistor bc 107,crystal 6.144 mhz,ic base 16 pins,ic base 28 pins,ic 7600,dry cell 1.5 nv,at mega 328 p set,lcd 16x2,duvcon mager complete sticker,22 ohm,printer i.c.,module cell for date and time,ic base 20 pin,complete power supply,scale screw,carrier handle,body universal without spare,rachet handle,max 232,pressure plate,ic 74373,spur gear axle,wooden box big small,body dmm,plunger agro,crank handle agro,top plunger,bottom plunger,circular scale,bk handle test cup,pcb l

Calibration and repair of moisture meter,test cup,spur gear,bevel gear,guide nut,insulation disk,thrust bearing,bevel pinion,micro controller,electronic switch,com. pcb,com. meggar box,temperature sensor,i.c. regulator 7805,timer i.c. 7555,i.c 4051,i.c 7447,eprom,f.n.d. board,ic 7135,complete body universal,bracket,spur pinion bigsmall,40 pin header set,pinion brush,lead screw,volume cup a,volume cup b,volume cup c,allen key,battery compartment,adaptor,connector leads 12 pin,connector leads 2 3 pins,relay,segment i.c.,i.c. 7600,switching transistor bc 107,crystal 6.144 mhz,ic base 16 pins,ic base 28 pins,ic 7600,dry cell 1.5 nv,at mega 328 p set,lcd 16x2,duvcon mager complete sticker,22 ohm,printer i.c.,module cell for date and time,ic base 20 pin,complete power supply,scale screw,carrier handle,body universal without spare,rachet handle,max 232,pressure plate,ic 74373,spur gear axle,wooden box big small,body dmm,plunger agro,crank handle agro,top plunger,bottom plunger,circular scale,bk handle test cup,pcb l

Read more
Control valve characteristics,calibration of thermocouple,dynamic response of the u tube manometer,interacting non interacting system,proportional p and proportional integral pi controllers for flow and level control,time constant of the stirred tank heater,temperature control trainer with computer system,pressure control trainer,p i i p convertor,capacitance method,nephelometer or turbidimeter,hot air oven,muffle furnace,jar test apparatus,high volume air sampler pm10,fine particulate sampler pm2.5,biochemical oxygen demand analyzer,cod reflux apparatus with cod digester,bomb calorimeter,biogas digester or anaerobic digester,melting point apparatus,ball mill,air compressor,oil free vacuum pump,ultra violet flourescene inspection cabinet

Control valve characteristics,calibration of thermocouple,dynamic response of the u tube manometer,interacting non interacting system,proportional p and proportional integral pi controllers for flow and level control,time constant of the stirred tank heater,temperature control trainer with computer system,pressure control trainer,p i i p convertor,capacitance method,nephelometer or turbidimeter,hot air oven,muffle furnace,jar test apparatus,high volume air sampler pm10,fine particulate sampler pm2.5,biochemical oxygen demand analyzer,cod reflux apparatus with cod digester,bomb calorimeter,biogas digester or anaerobic digester,melting point apparatus,ball mill,air compressor,oil free vacuum pump,ultra violet flourescene inspection cabinet

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise