Tender Details
Particulars | Details |
---|---|
Title |
Power Contactor 70 Am Ps, 415 V, Triple Pole, With 2 No2 Nc Aux Contacts (Side Mounting), Coil Voltage 415 V Ac, Confirming To Is/Iec 60947, Part 4/Sec 1. As Per Rcf Specification No. Edts 041, Rev. B. Suitable For Use In 200 A Battery Charging Unit Of Sg Ac Coaches.
Accepted Make : Siemens. Abb, L&T. Schneider Only.
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106553548 |
Reference Number |
40241467 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Jaipur |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/032025/106553548/viewNitPdf_4805416.pdf |
Start Date | December 14, 2024 13:08 |
End Date |
31/03/2025 ( Expired 20 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Power contactor 70 amps, 415 v, triple pole, with 2 no2nc aux contacts (side mounting), coil voltage 415v ac, confirming to is/iec 60947, part 4/sec 1. as per rcf specification no. edts-041, rev.-b. suitable for use in 200a battery charging unit of sg ac coaches. accepted make : siemens. abb, l&t. schneider only.
For complete deion and other details, please refer to tender
Read moreThree pole power contactor complete, 1kv, control voltage ac 440v plus 10 percent / minus 20 percent, 50hz, current 630 amp. with aux. contacts 4 no plus 4 nc, as per sr no. 21 of bill of material of annexure-b of rcf specification no. edts-103, rev-d with amendment no. 7, and confirming to rcf specification no. edts-103, rev-d with amendment no. 7, make: rcf / rdso approved.
For complete deion and other details, please refer to tender
Read moreMotor protection circuit breaket (mpcb) of rated current 1-1.6 amp with 2 nos aux contacts (1no1nc aux contact block), thermal range 1-1.6 amp, class-10, breaking capacity-50ka, 3pole, rated voltage 690vac, confirming to rdso modification sheet no. rdso/pe/ms/tl/0090-2023 (rev-0). rdso approved make & cat no.:- abb cat no. ms116-1.6, hk1-11, schneider cat no. gv2-me06gv-ae11, siemens cat no. 3rv20111aa103rv2901-1e, and l&t cat no. st418940000st419450000.
For complete deion and other details, please refer to tender
Read moreSupply of 200a 4 pole power contractor for 750 v ac as well as 415v ac with coil voltage 415v ac type cal 16-11a with surge suppressor similar to abb model-ek 110 with aux contract 2 no 2nc type cal, 16-11a as per bom edts 103rev d
For complete deion and other details, please refer to tender
Read moreAmalgamated pre-cooling transformer cum rectifier unit (battery charger) 200a, 130v, dc for sg ac coaches with stainless steel enclosure for charging vrla batteries confirming to rcf spec. no. edts.041 (rev.b) with icf amendment no.1, 2 & 3 and amended as per dy.cee/ds note no. md/dss/spec/211 dt.11.09.2001. however, the firms may quote for latest specn./drawing with amendment if any issued by rdso/icf/rcf.
For complete deion and other details, please refer to tender
Read moreHrc fuse link 6 amps capacity, 2 hole fixing bolted, 415v ac, having rupturing capacity 80 ka, a2, 3nw tia of siemens/gs/ge/abb make confirming to is: 13703-part-ii or latest as per rcf drawing no. cc72082 of edts 355. accepted make siemens,gs,ge & abb.
For complete deion and other details, please refer to tender
Read moreDouble pole miniature circuit breaker (mcb) 2.0 amps,110/130 v dc, equivalent to part. no. 5sy52027cc of siemens make, part. no. bj2002dc of l&t make to is: s/iec 60947-2 accepted make- legrand,siemens, abb, l&t, schneider only.
For complete deion and other details, please refer to tender
Read moreDin type hrc fuse link 40 amps with rate [din type hrc fuse link 40 amps with rated breaking capacity 120ka, 415v/500v, 50hz operating class gg, size 000 of siemens catalogue no. 3na7817- orc or equivalent make confirming to is: 13703 (pt.2/sec-1) /1993, accepted make:- 1) siemens, 2) l&t, 3) c&s, 4) bussmann 5) kel. and 6) rbco. fuse link shall be isi marked & as per rcf drawing no. lw 71001 alt- h & lw 71002 alt i . ]
For complete deion and other details, please refer to tender
Read moreK44 contactor for 60kva transformer rate [k44 contactor for 60kva transformer rated current: 200a, rated voltage:690v ac, main pole:4, aux contact :01no1nc, control voltage:230v ac (168 v ac-300 v ac means 230v ac /- 30 percent ) with surge suppressor as per item no.k01 of bill of material of rdso spec no. rdso/pe/spec/d/0184-2015 (rev.1) suitable for lhb type ac coaches switch board cabinet. brands: l&t/siemens/schneider/abb only. 1) the firm should submit authorized dealership certificate
For complete deion and other details, please refer to tender
Read moreContactor 3 pole, 16 amp capacity suitable for 415v, 50 hz ac, coil voltage 110 dc with surge suppressor ( coil voltage range 77-137 v dc) with inc auxiliery contack block similar to abb code tal-16-30-01, rt 5/150 generally conforming to is- 13947 pt.- 4/1993.] accepted makes: abb, schneider, siemens.
For complete deion and other details, please refer to tender
Read moreof your Industry type