Tender Details
About Tender
🔋 Invitation For Bids: 4 Quadrant Dc Drive System 🔧🏭 The Indian Institute Of Engineering Science And Technology (Iiest) Shibpur, Under The Aegis Of The Central Government's Ministry/Department, Is Seeking Bids For The Supply And Installation Of A 4 Quadrant Dc Drive System. 📅 Bid Submission Deadline: April 14, 2024, 6:00 Pm The System Includes A Vacuum Impregnated Dc Motor With A Rating Of 2 K W, 1400 Rpm, Equipped With A Tachogenerator/Encoder, Switchgear Panel, Filters, Sensors, Sensor Cards, And A Loader For 1 Set. Interested Bidders Must Submit A Tender Fee Of Inr 1000 And An Earnest Money Deposit (Emd) Of Inr 15600. Detailed Bids, Including Technical Specifications, Pricing, And Implementation Timelines, Are To Be Submitted As Per The Tender Document. Keywords: E Procurement, Dc Drive System, Vacuum Impregnated Dc Motor, Iiest Shibpur, Electrical Engineering, Tender, Bid Submission, Emd, Tender FeeParticulars | Details |
---|---|
Title |
E Proc/Dcdrive 22032024/ Ee Iiest/570 R
|
Description |
Supply And Installation Of 4 Quadrant Dc Drive System With Vacuum Impregnated Dc Motor, 2 K W, 1400
Rpm, With Tachogenerator/ Encoder, Switchgear Panel, Filters, Sensors, Sensor Cards, Loader 1 Set
|
Organisation | Indian Institute of Engineering Science and Technology - Shibpur | Central Govt. Ministry/Department |
Tender Id | 2024_IIEST_802082_1 |
Reference Number |
e-Proc/DCDRIVE_22032024/ EE_IIEST/570R |
Tender Fee | 1000 |
EMD | 15600 |
Tender Value | |
Place | Department of Electrical Engineering, IIEST, Shibp |
Link | https://eprocure.gov.in/eprocure/app?page=FrontEndTenderDetailsExternal&service=page&tnid=843118 |
Start Date | March 23, 2024 16:30 |
End Date |
14/04/2024 ( Expired 394 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
1. 2 hp (1.5 kw) single phase-submersible pump set with starter control panel. supply voltage : single phase, 230 volt ac, 50 hz, numbers of poles of motor : 2 pole, speed of pump(rpm): 2900, discharge capacity (lps): 0.5, discharge head: 100 meter, bore size: 100 millimeter, delivery size: 32 millimeter, nos of stages for submersible pump: 27, bee energy star rating : 5 star, non valve : yes, erection clamp : yes, control panel with er, isi marked mcb /main switch, ammeter, voltm
For complete deion and other details, please refer to tender
Read moreSupply, installation, & commissioning of test for testing of speed sensor rings of tm. testing consisting of (1) motor : 3 phase/415v/1hp/ 3000 rpm 50 hz. (2) three phase vvvf ac drive for 1 hp motor. (3) test wheel having 120 teeth for mounting of speed sensor ring. (4) fixture for mounting hall effect speed sensor. (5)50 mhz, 2 channel digital storage oscilloscope to view sensor output wave form. make: g.t. electronics or its equivalent.
For complete deion and other details, please refer to tender
Read moreInstallation of diesel pump-motor set, laying of m.s. pipe line at laikera railway bridge for transporting water with insta n comm of sensor actuated plc based fully automatic foggy dense-mist generating system with amc 2 years at laikera kocp ba
Installation of diesel pump-motor set, laying of m.s. pipe line at laikera railway bridge for transporting water with insta n comm of sensor actuated plc based fully automatic foggy dense-mist generating system with amc 2 years at laikera kocp ba
Read moreSupply, installation, testing and commis [supply, installation, testing and commissioning of hvls fan 12 feet sweep with bldc/pmsm motor with gearless drive. down rod (1.5 to 2 mtrs long), hub, aero foil magnalium blades, vfd control panel. metal guy wires (4 nos.) as safety ropes, no. of blades: 5 or 6, air volume: 213540 cubic meter per hour, rated fan speed: 10 rpm, maximum fan speed: 90 rpm. mounting type: ceiling, motor rating: not more than 400 watts, power supply: 220 volts, 50 hz. mini
For complete deion and other details, please refer to tender
Read moreSupply and installation of motor gearbox along with 0.75 kw , 2a, 3 phase, 440v, 50hz, 1400 rpm induction motor as per is:325 (1996) suitable for universal testing machine with class f insulation, frame size 906 along with vertical gear system. make: siemens, abb, cg or equivalent.
For complete deion and other details, please refer to tender
Read more659018970056 (supply)-supply, installation, & commissioning of test for testing of speed sensor rings of tm. testing consisting of (1) motor : 3 phase/415v/1hp/3000 rpm 50 hz. (2) three phase vvvf ac drive for 1 hp motor. (3) test wheel having 200 teeth for mounting of speed sensor ring. (4) fixture for mounting hall effect speed sensor. (5) 20 mhz, 2 channel digital storage oscilloscope to view sensor output wave form. make: g.t. electronics or its equivalent.
For complete deion and other details, please refer to tender
Read more1. 2 hp (1.5 kw) single phase-submersible pump set with starter control panel. supply voltage : single phase, 230 volt ac, 50 hz, numbers of poles of motor : 2 pole, speed of pump(rpm): 2900, discharge capacity (lps): 0.5, discharge head: 100 meter, bore size: 100 millimeter, delivery size: 32 millimeter, nos of stages for submersible pump: 27, bee energy star rating : 5 star, non valve : yes, erection clamp : yes, control panel with er, isi marked mcb /main switch, ammeter, voltm
For complete deion and other details, please refer to tender
Read more659018970056 (supply)-supply, installation, & commissioning of test for testing of speed sensor rings of tm. testing consisting of (1) motor : 3 phase/415v/1hp/3000 rpm 50 hz. (2) three phase vvvf ac drive for 1 hp motor. (3) test wheel having 200 teeth for mounting of speed sensor ring. (4) fixture for mounting hall effect speed sensor. (5) 20 mhz, 2 channel digital storage oscilloscope to view sensor output wave form. make: g.t. electronics or its equivalent.
For complete deion and other details, please refer to tender
Read moreAc drive 37kw/50hp. supply & testing of [ac drive 37kw/50hp. supply & testing of ac drive specification 1.ac drive required to drive squirrel cage im:37kw/50hp, 3ph, 415vac, 50hz, 4pole/6pole, s4 duty for crane hoist/ lt, application. 2.ac drive mains supply:3ph, 380-400vac 50hz. 3.ac drive o/p rating, high overload capacity:37kw 4.drive o/p rating, normal ol capacity:45kw 5.panel mounting type, protection:ip-20 6.drive to work without encoder feedback system with suitable current feedback sy
For complete deion and other details, please refer to tender
Read moreSupply & installation of aerosol fire detection & suppression system cartridge for sg ac coaches as per rdso letter no. el/7.1.108/mssbc/main dt. 12.05.2022, (a) 1 no. of minimum 40 gm for power panel of sgac coach (b) 2 no. of minimum 15 gm for both rmpu control panel of sgac coach (c) 1 no. of minimum 10 gm for inverter panel of sgac coach , (total 4 nos= 1 set ) may be provided in line with technical parameters as per annexure g 1 of spec. no. rdso/pe/spec/ac/0192-2018 (rev-1). all necessa
For complete deion and other details, please refer to tender