Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
About Tender
🩺 Urgent Bid Invitation: Sirolimus Coated Drug Eluting Coronary Stent 💊 The Department Of Health Research, Under The Ministry Of Health And Family Welfare, Is Seeking Bids For The Procurement Of Sirolimus Coated Drug Eluting Coronary Stents. 🧬 🗓️ Bid Submission Deadline: May 24, 2024, 4:00 Pm Suppliers Must Provide Detailed Bids That Include Technical Specifications, Pricing, And Evidence Of Compliance With Medical Safety And Efficacy Standards. Keywords: Sirolimus Coated Drug Eluting Coronary Stent, Procurement, Medical Devices, Health Research, Ministry Of Health And Family Welfare, Bid Submission| Particulars | Details |
|---|---|
| Title |
Sirolimus Coated Drug Eluting Coronary Stent
|
| Description |
|
| Organisation | Department of Health Research | Ministry of Health and Family Welfare |
| Tender Id | GEM/2024/B/4907728 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | May 02, 2024 21:46 |
| End Date |
Expired
24/05/2024
Expired 878 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
TIRUMALA MEDICAL AND PHARMA DISTRIBUTORS
7938000
Technical Evaluation Results
| S.No. | Seller Name | Offered Item | Participated On | EMD Status | MSE/MII Status | Status |
|---|---|---|---|---|---|---|
| 1 | ENVISION SCIENTIFIC PRIVATE LIMITED | Make : ENVISION SCIENTIFIC PRIVATE LIMITED Model : NOSTRUM Title : SIROLIMUS ELUTING CORONARY STENT SYSTEM | 24-05-2024 15:31:35 | Offline upload | N/A | Disqualified |
| 2 | INVENT BIO-MED PRIVATE LIMITED | Make : Nova Matrix Model : 11 - ,14 - ,19 - ,24 - Length (mm) ,11 - ,14 - ,19 Title : Sirolimus Eluting Coronary Stent System | 24-05-2024 14:14:01 | MSE | MSE | Disqualified |
| 3 | KAMAL ENCON INDUSTRIES LIMITED | Make : KAMAL ENCON | TRACKFLEX Model : TRACKFLEX Title : SIROLIMUS COATED DRUG ELUTING CORONARY STENT SYSTEM | 23-05-2024 17:19:49 | Offline upload | N/A | Disqualified |
| 4 | Maruti Sales And Services Company | Make : Translumina Therapeutics LLP Model : Yukon Choice Flex Title : Yukon Choice Flex - Biodegradable Polymer Sirolimus Eluting Coronary Stent with Co-Cr Platform havin | 24-05-2024 15:36:08 | Offline upload | MII | Qualified |
| 5 | MERIL LIFE SCIENCES INDIA PRIVATE LIMITED | Make : Proficient Model : Proficient Title : Proficient Sirolimus Eluting Coronary Stent System | 24-05-2024 14:32:32 | Offline upload | N/A | Disqualified |
| 6 | NEWTECH MEDICAL DEVICES PRIVATE LIMITED | Make : Newtech Medical Devices Pvt. Ltd. Model : Auricle Title : Sirolimus Coated Drug Eluting Coronary Stent | 21-05-2024 17:32:55 | Vendor Assessed | MSE | Disqualified |
| 7 | ROHAK PHARMA | Make : Everolimus Coated Drug Eluting Coronary Stent (Q3) Model : Everolimus Coated Drug Eluting Coronary Stent (Q3) Title : Pristine | 24-05-2024 13:11:49 | Registered with designated Agency / Authority | N/A | Disqualified |
| 8 | TIRUMALA MEDICAL AND PHARMA DISTRIBUTORS | Make : Supralimus Grace Model : Sirolimus Coated Drug eluting Coronary Stent Title : Supralimus Grace | 23-05-2024 16:58:41 | Offline upload | MII | Qualified |
Financial Evaluation Results
| S.No. | Seller Name | Offered Item | Total Price | Rank |
|---|---|---|---|---|
| 1 | TIRUMALA MEDICAL AND PHARMA DISTRIBUTORS(MII) | Item Categories : Sirolimus Coated Drug Eluting Coronary Stent | 7938000.00 | L1 |
| 2 | Maruti Sales And Services Company (MII) | Item Categories : Sirolimus Coated Drug Eluting Coronary Stent | 17010000.00 | L2 |
Ordered Items & Contract Pricing
| Product | Brand | Model | Ordered Quantity | Price |
|---|---|---|---|---|
| Supralimus Grace | Supralimus Grace | Sirolimus Coated Drug eluting Coronary Stent | 720 | ₹ 7938000.000 |
Hq_med_sur_ph:.(153049) drug eluting coronary stent system - platinum chromium hdvd - pvf everolimus drug eluting stent 2.25 mm to 4 mm all size
Hq_med_sur_ph:.(153049) drug eluting coronary stent system - platinum chromium hdvd - pvf everolimus drug eluting stent 2.25 mm to 4 mm all size
Read moreSirolimus eluting coronary stent system with biodegradable polymer on cobalt chromium platform with active coating per set
Sirolimus eluting coronary stent system with biodegradable polymer on cobalt chromium platform with active coating per set
Read moreVascular sheath radial artery 5 fr,vascular sheath radial artery 6 fr,vascular sheath femoral artery 6 fr,vascular sheath femoral artery 7 fr,vascular sheath femoral artery 8 fr,pressure monitoring line 200 cm maletofemale,high pressure line mf 120cm braided 1200 psi,manifold 2 port,unolock syringe 10 ml,temporary pacing wire 6 fr,puncture needle 18g,ptca guidewire hydrophilic 0.014 180 cm 2 mm distal tip,ptca guide wire standard,ptca guidewire hydrophilic,drug eluting stent everolimus cocr 100 micrometre usfda,drug eluting stent sirolimus cocr 100 micrometre usfda,drug eluting stent zotarolimus cocr 100 micrometre usfda,drug eluting stent biolimus a9 cocr 100 micrometre usfda,drug eluting stent everolimus ptcr 100 micrometre usfda,drug eluting stent sirolimus ptcr 100 micrometre usfda,drug eluting stent zotarolimus ptcr 100 micrometre usfda,drug eluting stent biolimus a9 ptcr 100 micrometre usfda,double lumen ptmc balloon dilatation catheter with complete accessories,mullins sheath 8 fr,guide wire 0.032 x 26
Vascular sheath radial artery 5 fr,vascular sheath radial artery 6 fr,vascular sheath femoral artery 6 fr,vascular sheath femoral artery 7 fr,vascular sheath femoral artery 8 fr,pressure monitoring line 200 cm maletofemale,high pressure line mf 120cm braided 1200 psi,manifold 2 port,unolock syringe 10 ml,temporary pacing wire 6 fr,puncture needle 18g,ptca guidewire hydrophilic 0.014 180 cm 2 mm distal tip,ptca guide wire standard,ptca guidewire hydrophilic,drug eluting stent everolimus cocr 100 micrometre usfda,drug eluting stent sirolimus cocr 100 micrometre usfda,drug eluting stent zotarolimus cocr 100 micrometre usfda,drug eluting stent biolimus a9 cocr 100 micrometre usfda,drug eluting stent everolimus ptcr 100 micrometre usfda,drug eluting stent sirolimus ptcr 100 micrometre usfda,drug eluting stent zotarolimus ptcr 100 micrometre usfda,drug eluting stent biolimus a9 ptcr 100 micrometre usfda,double lumen ptmc balloon dilatation catheter with complete accessories,mullins sheath 8 fr,guide wire 0.032 x 26
Read moreSmall arterial sheath,medium arterial sheath,large arterial sheath,2 way manifold,y connector,0.35 inch straight tipped ptfe wire regular length,0.35 inch ptfe j tipped wire exchange length,puncture needle radial artery,puncture needle femoral artery,polymer jacketed 0.35inch wire regular length,polymer jacketed 0.35inch wire exchange length,tavi valve,thrombus aspiration catheter,pigtail catheter,3 way manifold,transcatheter implantable pulmonary valve,inflation device,semicomplaint coronary balloons,noncomplaint coronary balloons,sirolimus eluting coronary stents size 4.5mm diameter or more,everolimus drug eluting stent,polymer free coronary stent
Small arterial sheath,medium arterial sheath,large arterial sheath,2 way manifold,y connector,0.35 inch straight tipped ptfe wire regular length,0.35 inch ptfe j tipped wire exchange length,puncture needle radial artery,puncture needle femoral artery,polymer jacketed 0.35inch wire regular length,polymer jacketed 0.35inch wire exchange length,tavi valve,thrombus aspiration catheter,pigtail catheter,3 way manifold,transcatheter implantable pulmonary valve,inflation device,semicomplaint coronary balloons,noncomplaint coronary balloons,sirolimus eluting coronary stents size 4.5mm diameter or more,everolimus drug eluting stent,polymer free coronary stent
Read moreHq_med_sur_zrc_zonal rate contract for supply of ph:.(153045) sirolimus eluting stent cobalt - chromium stent with abluminal coating and specialised gradient coating (no polymer coating at joint & bends). bioresorbable polymer of plcl (poly lactic acid + poly caprolactone pcl) with degradation time of 3-4 months. low concentration of sirolimus (0.8ug/mm sq) should have bio-inspired open-cell. pmda approved
Hq_med_sur_zrc_zonal rate contract for supply of ph:.(153045) sirolimus eluting stent cobalt - chromium stent with abluminal coating and specialised gradient coating (no polymer coating at joint & bends). bioresorbable polymer of plcl (poly lactic acid + poly caprolactone pcl) with degradation time of 3-4 months. low concentration of sirolimus (0.8ug/mm sq) should have bio-inspired open-cell. pmda approved
Read moreOvered coronary stent pre [srphc82281260-covered coronary stent pre-mounted on a balloon catheter. should be available in various range of lengths from 15 to 30mm and diameters from 2.5 to 4mm .]
Overed coronary stent pre [srphc82281260-covered coronary stent pre-mounted on a balloon catheter. should be available in various range of lengths from 15 to 30mm and diameters from 2.5 to 4mm .]
Read moreEverolimus drug eluting coronary stent on platinum chromium platform - bioabsorable with abluminal coating. additional connectors 4/5 in the proximal 2 segments. strut thickness 1.5 mm. available sizes 2.25 mm to 5.0 mm in diameter, 8.0 mm to 48 mm in length. 2 connector design throughout the body mecd >7.0 mm.
Everolimus drug eluting coronary stent on platinum chromium platform - bioabsorable with abluminal coating. additional connectors 4/5 in the proximal 2 segments. strut thickness 1.5 mm. available sizes 2.25 mm to 5.0 mm in diameter, 8.0 mm to 48 mm in length. 2 connector design throughout the body mecd >7.0 mm.
Read moreVascular suture mediated closure and repair system sterile with 3 point 0 mono filamen polypropylene suture 300 series stainless steel needles,non complaint ballon,holter patches disposable nc 1340 web cardio 7 days er proof wireless multiday holter patch sp7,everolimus eluting balloon mounted platinum chromium coronary stent system assorted size,flexible lead free radiation shield,high pressure 3 port manifold,dedicated kit angiography for radial,coronary angioplasty kit,zotarolimus eluting balloon expandable cobalt alloy coronary stent system with continuous sinusoidal design assorted size,terumo angiography guide wire 0 point 035 x 150 cm j tip,hp laser toner cartridge for hp laser 103a
Vascular suture mediated closure and repair system sterile with 3 point 0 mono filamen polypropylene suture 300 series stainless steel needles,non complaint ballon,holter patches disposable nc 1340 web cardio 7 days er proof wireless multiday holter patch sp7,everolimus eluting balloon mounted platinum chromium coronary stent system assorted size,flexible lead free radiation shield,high pressure 3 port manifold,dedicated kit angiography for radial,coronary angioplasty kit,zotarolimus eluting balloon expandable cobalt alloy coronary stent system with continuous sinusoidal design assorted size,terumo angiography guide wire 0 point 035 x 150 cm j tip,hp laser toner cartridge for hp laser 103a
Read moreScoring ballon with 120 degree angulated scoring element for complex,proximal optimization and distal optimization technique non compliant,sirolimus drug eluting ballon with cell adherent micro reservior sustained,high pressure semi comliant ballon dilation catheter with eel and slider,high pressure cutting ballon
Scoring ballon with 120 degree angulated scoring element for complex,proximal optimization and distal optimization technique non compliant,sirolimus drug eluting ballon with cell adherent micro reservior sustained,high pressure semi comliant ballon dilation catheter with eel and slider,high pressure cutting ballon
Read moreThis stent combines lumen apposing metal stent (lams).
This stent combines lumen apposing metal stent (lams).
Read moreof your Industry type