Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Thorough Repairing And Upgradation Of Nhs Type Block No. 01/01 08 (04 Units), 02/09 16 (05 Units), 03/17 24 (06 Units), 04/25 32 (06 Units), 05/33 40 (08 Units), Total 29 Units Full At Computer Center Colony Under Kunustoria Area Office. (2nd Call)
|
| Description |
Thorough Repairing And Upgradation Of Nhs Type Block No. 01/01 08 (04 Units), 02/09 16 (05 Units), 03/17 24 (06 Units), 04/25 32 (06 Units), 05/33 40 (08 Units), Total 29 Units Full At Computer Center Colony Under Kunustoria Area Office. (2nd Call)
|
| Organisation | Eastern Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2024_ECL_303850_1 |
|
Reference Number |
ECL/GM/KNT/CIVIL/E-TENDER/ 23-24/384 |
| Tender Fee | 0 |
| EMD | 60100 |
| Tender Value | - |
| Place | Kunustoria Area |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=314760 |
| Start Date | March 09, 2024 16:30 |
| End Date |
Expired
19/03/2024
Expired 941 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Nagar panchayat dankaur me ward no-05, 06, 07, 08 me marammat ka kary.
Nagar panchayat dankaur me ward no-05, 06, 07, 08 me marammat ka kary.
Read moreRepairing work at ward no 04, 05, 06 and 07 under housing zone pithampur
Repairing work at ward no 04, 05, 06 and 07 under housing zone pithampur
Read moreNagar panchayat nawabganj me ward no. 04, 05, 06 me avshyaktanusar solar mini nalkoop samarsebil adhishthapan
Nagar panchayat nawabganj me ward no. 04, 05, 06 me avshyaktanusar solar mini nalkoop samarsebil adhishthapan
Read moreTerm contract for repair maintenance of drain in ward no.05, 06, 07 and 08 of cantonment board ramgarh
Term contract for repair maintenance of drain in ward no.05, 06, 07 and 08 of cantonment board ramgarh
Read moreSpl repair to or md accn no ar 26/01, 08 and ar 27/01, 05 and 07 (total- 05 x md accn) of karam singh enclave at pms
All as per boq
Read moreItem no 01,item no 02,item no 03,item no 04,item no 05,item no 06,item no 07
Item no 01,item no 02,item no 03,item no 04,item no 05,item no 06,item no 07
Read morePainting and white washing work in government residential and non residential building under section no. 03, 04 05 and 08 of the west sub division, p.w.d. bhopal.
Painting and white washing work in government residential and non residential building under section no. 03, 04 05 and 08 of the west sub division, p.w.d. bhopal.
Read moreAnnual maintenance contract of split type ac units at f-type govt. bungalows/quarters ( f-02, f-03, f-04, f-05, f-05, f-06, f-07, f-10, f-a1, fa2, f-a3, f-a4, f-b1, f-b2, f-b3, f-b4, f-b5) at altinho, panaji - goa for the period of one year.
Annual maintenance contract of split type ac units at f-type govt. bungalows/quarters ( f-02, f-03, f-04, f-05, f-05, f-06, f-07, f-10, f-a1, fa2, f-a3, f-a4, f-b1, f-b2, f-b3, f-b4, f-b5) at altinho, panaji - goa for the period of one year.
Read moreSpl repair of sewage line and drainage system near bldg no cl-02, cl-04, cl-05, cl-06 and cl-08 and toilet near pers line (mh-43), ladies toilet in new mi room (mk-480) and toilet back side at mil stn kota
Spl repair of sewage line and drainage system near bldg no cl-02, cl-04, cl-05, cl-06 and cl-08 and toilet near pers line (mh-43), ladies toilet in new mi room (mk-480) and toilet back side at mil stn kota
Read moreJaw plate swing jaw p no dtjc 2415 03 02,jaw plate stationary jaw p no dtjc 2415 02 02,swing jaw keeper plate p no dtjc 2415 03 03,swing jaw keeper plate holding bolt p no dtjc 04 07c,stationary jaw keeper plate p no dtjc 2415 02 03,stationary jaw keeper plate holding bolt p no dtjc 2415 04 07b,pull back rod p no dtjc 2415 07 07,pull back rod spring p no dtjc 2415 07 05,rubber diaphragm p no dtjc 2415 06 03,lower wear plate p no dtjc 2415 01 07,lower wear plate holding bolt p no dtjc 2415 08 07,guard plate p no dtjc 2415 03 03,eccentric shaft p no dtjc 2415 05 01,bearing p no dtjc 2415 05 02,pitman p no dtjc 2415 04 01,front toggle p no dtjc 2415 04 02 24 12 06,rear toggle p no dtjc 2415 04 02 24 12 05,toggle pin p no dtjc 2415 04 06,toggle seat p no dtjc 2415 04 07,toggle spring p no dtjc 2415 04 04,stationary jaw holding stud for upper bl p no dtjc 2415 01 03,flywheel bush p no dtjc 2415 05 09,safety shoe p no dtjc 2415 02 03,safety arm key p no dtjc 2415 05 05a,safety flat p no dtjc 06 026,side plate p no
Jaw plate swing jaw p no dtjc 2415 03 02,jaw plate stationary jaw p no dtjc 2415 02 02,swing jaw keeper plate p no dtjc 2415 03 03,swing jaw keeper plate holding bolt p no dtjc 04 07c,stationary jaw keeper plate p no dtjc 2415 02 03,stationary jaw keeper plate holding bolt p no dtjc 2415 04 07b,pull back rod p no dtjc 2415 07 07,pull back rod spring p no dtjc 2415 07 05,rubber diaphragm p no dtjc 2415 06 03,lower wear plate p no dtjc 2415 01 07,lower wear plate holding bolt p no dtjc 2415 08 07,guard plate p no dtjc 2415 03 03,eccentric shaft p no dtjc 2415 05 01,bearing p no dtjc 2415 05 02,pitman p no dtjc 2415 04 01,front toggle p no dtjc 2415 04 02 24 12 06,rear toggle p no dtjc 2415 04 02 24 12 05,toggle pin p no dtjc 2415 04 06,toggle seat p no dtjc 2415 04 07,toggle spring p no dtjc 2415 04 04,stationary jaw holding stud for upper bl p no dtjc 2415 01 03,flywheel bush p no dtjc 2415 05 09,safety shoe p no dtjc 2415 02 03,safety arm key p no dtjc 2415 05 05a,safety flat p no dtjc 06 026,side plate p no
Read moreof your Industry type