Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Work Of Increasing The Capacity Of Power Transformer Under Edd I, Mau And Edd Ii, Mau And Work Of Installation/Repair Of Ct, Pt, La, Bus Isolator, Line Isolator, Control Panel Under Edd Ii, Mau In 20 Cr Per District Plan
|
| Description |
Work Of Increasing The Capacity Of Power Transformer Under Edd I, Mau And Edd Ii, Mau And Work Of Installation/Repair Of Ct, Pt, La, Bus Isolator, Line Isolator, Control Panel Under Edd Ii, Mau In 20 Cr Per District Plan
|
| Organisation | Government of Uttar Pradesh |
| Tender Id | 2023_PVVNV_845841_1 |
|
Reference Number |
57/EDC(M)/2023-24 |
| Tender Fee | 3540 |
| EMD | 16000 |
| Tender Value | - |
| Place | SE EDC Mau |
| Link |
View Original Tender Notice
https://etender.up.nic.in |
| Start Date | October 04, 2023 14:30 |
| End Date |
Expired
09/10/2023
Expired 1100 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Special repair/replacement of transformer against ber at tanda and provn of ct/pt unit alongwith trivector meter at mrs under ge (north) akhnoor
Special repair/replacement of transformer against ber at tanda and provn of ct/pt unit alongwith trivector meter at mrs under ge (north) akhnoor
Read moreProcurement of seal off bushings for bus duct of generator transformer, uat, pt cubicle, and ngt for 2x600mw, sstpp, mppgcl, dongalia.
Procurement of seal off bushings for bus duct of generator transformer, uat, pt cubicle, and ngt for 2x600mw, sstpp, mppgcl, dongalia.
Read moreRepair and maint of transformer vaccum circuit breaker servo voltage stabilizer and other ht panel ct/pt and ht cable ht joint and other misc connected workt at bhdc under ge (east) delhi cantt-10
Repair and maint of transformer vaccum circuit breaker servo voltage stabilizer and other ht panel ct/pt and ht cable ht joint and other misc connected workt at bhdc under ge (east) delhi cantt-10
Read moreDe-paralleling of 2nos. 80mva ptrs and erection of new 33kv pt set to 33kv bus section-iii and erection of 100kva station transformer at 132kv ss asifnagar in omc/metro-cetnral circle/metro zone-i
De-paralleling of 2nos. 80mva ptrs and erection of new 33kv pt set to 33kv bus section-iii and erection of 100kva station transformer at 132kv ss asifnagar in omc/metro-cetnral circle/metro zone-i
Read moreRepairs and replacement of spares to 11 kv switch yards de-hydration of power and distribution transformers bus trunking system ct pt voltage stabilizers battery banks etc at eetf dsst dsp cic mrsam army mrsam af 0208 0204 agni plasma avc data center
Repairs and replacement of spares to 11 kv switch yards de-hydration of power and distribution transformers bus trunking system ct pt voltage stabilizers battery banks etc at eetf dsst dsp cic mrsam army mrsam af 0208 0204 agni plasma avc data center
Read moreAuxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read moreVcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreUnder the municipal corporation plan, work of increasing the capacity of power transformer and installation of additional power transformer under edd-i, mau and work of installation of ct and isolator edd-ii, mau.
Under the municipal corporation plan, work of increasing the capacity of power transformer and installation of additional power transformer under edd-i, mau and work of installation of ct and isolator edd-ii, mau.
Read moreCapacity enhancement of power transformer and installation of la, ct, pt, isolatore under edd-3rd ghosi
Capacity enhancement of power transformer and installation of la, ct, pt, isolatore under edd-3rd ghosi
Read moreErection, testing n commissioning of new ct, pt, la, isolator mb box n making of new earth pit by replacing old ct, pt, la n isolator mechanism box
Erection, testing n commissioning of
 new ct, pt, la, isolator mb box n making of new earth pit by replacing
 old ct, pt, la n old isolator mechanism box at 132/33 kv sub-station, nandira under jagannath area, mcl
Read moreof your Industry type