Tender Details

Particulars Details
Title
Set Of External Mu Couplers(male Pins & Female Pins) Consisting Of 02 Items As Follows. 1) External Coupler Having Male Pins 120nos(ref. 7) Along With Cable Sleeves 120nos(ref. 8) As Per Clw Spec. Clw/Es/C 8/J Or Latest. One Consisting Of 240 Numbers In Total. Qty/Set. = 01 Set. 2) External Coupler Having Female Pins 120nos(ref. 13) Along With Cable Sleeves 120nos(ref. 8) As Per Clw Spec. Clw/Es/C 8/J Or Latest. One Consisting Of 240 Numbers In Total. Qty/Set. = 01 Set
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 106786337
Reference
Number
LB255358B
Tender Fee 0
EMD 0
Tender Value -
Place Secunderabad
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/082025/106786337/viewNitPdf_5068280.pdf

Start Date August 05, 2025 15:09
End Date
Expired 29/08/2025

Expired 414 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Master controller with 06 main components (a) angle transmitters (b) connector 13 pins (c) sub-d connectors (d) reverser-switch (e) cam switches (f) spring as per clw spec. no.-clw/es/3/0031 alt- j with latest alteration specn./drg no-clw spec. no.-clw/es/3/0031 alt-j with latest alteration.

Master controller with 06 main components (a) angle transmitters (b) connector 13 pins (c) sub-d connectors (d) reverser-switch (e) cam switches (f) spring as per clw spec. no.-clw/es/3/0031 alt- j with latest alteration specn./drg no-clw spec. no.-clw/es/3/0031 alt-j with latest alteration.

Read more
Rubber gasket having length 3.5 mtrs each nos. for oil cooling blower (ocb) dome as per ref.10 of clw drg.no. clw/es/3/0023 alt-h or latest. as above.

Rubber gasket having length 3.5 mtrs each nos. for oil cooling blower (ocb) dome as per ref.10 of clw drg.no. clw/es/3/0023 alt-h or latest. as above.

Read more
Master controller with 06 main components (a) angle transmitters (b) connector 13 pins (c) sub-d connectors (d) reverser-switch (e) cam switches (f) spring specn./ drg no - as per clw spec. no.- clw/es/3/0031 alt-j.

Master controller with 06 main components (a) angle transmitters (b) connector 13 pins (c) sub-d connectors (d) reverser-switch (e) cam switches (f) spring specn./ drg no - as per clw spec. no.- clw/es/3/0031 alt-j.

Read more
Set of heat shrinkage sleeves (polyolefin) consisting of : (1) type 5a = 225m (2) type 6a = 12m, (3) type 7a = 8m, (4) type 10 = 6m, (5) type 11a = 22.5m, (6) type 12a = 4m to clw s spec. no. - clw/es/i-15 (alt. - i).

Set of heat shrinkage sleeves (polyolefin) consisting of : (1) type 5a = 225m (2) type 6a = 12m, (3) type 7a = 8m, (4) type 10 = 6m, (5) type 11a = 22.5m, (6) type 12a = 4m to clw s spec. no. - clw/es/i-15 (alt. - i).

Read more
Loco set of insulator assly. type b (without insulator) ref. 1 to 21 of sheet no. 21 of clw specn. no.clw/es/c49 alt.c. details of references to sheet no.15.17.18.19 of above specn.

Loco set of insulator assly. type b (without insulator) ref. 1 to 21 of sheet no. 21 of clw specn. no.clw/es/c49 alt.c. details of references to sheet no.15.17.18.19 of above specn.

Read more
Main circuit breaker (vcb) with its connector and 05 percent extra flexible reinforced rubber 27-inch-long air hose pipe i/d 5/16 with 3/8 bsp female coupling fitting at both ends as manufacturing spares to clw specification no. clw/es/c-47/i for fitment in wap-7 and wag-9 3 phase locomotives.

Main circuit breaker (vcb) with its connector and 05 percent extra flexible reinforced rubber 27-inch-long air hose pipe i/d 5/16 with 3/8 bsp female coupling fitting at both ends as manufacturing spares to clw specification no. clw/es/c-47/i for fitment in wap-7 and wag-9 3 phase locomotives.

Read more
Supply of radio communication test set as per attached technical specification,supply of rf coaxial cable double screened - 1 meter with n male to n-male connector,supply of rf coaxial cable double screened- 1 meter with n-male to n- female connector,supply of rf coaxial cable double screened- 1 meter with n-female to n- female connector,supply of bnc male to bnc male cable 2 meter,supply of bnc male to bnc female cable 2 meter,supply of lan cable 2 meter,supply of usb cable 1 meter,supply of rf adapter kit-1 no. inter-series n-type, sma, bnc, tnc,600 ohms balance to unbalance audio convertor with one end bnc male to connect to test and other end to connect the balanced line.,supply of ac power cord or dc adaptor with cord. if rechargeable internal battery will be charged by external battery charger, then battery charger also must be provided,supply of applicable software in cd or dvd or pen drive and hardware tools,sitc and training charges

Supply of radio communication test set as per attached technical specification,supply of rf coaxial cable double screened - 1 meter with n male to n-male connector,supply of rf coaxial cable double screened- 1 meter with n-male to n- female connector,supply of rf coaxial cable double screened- 1 meter with n-female to n- female connector,supply of bnc male to bnc male cable 2 meter,supply of bnc male to bnc female cable 2 meter,supply of lan cable 2 meter,supply of usb cable 1 meter,supply of rf adapter kit-1 no. inter-series n-type, sma, bnc, tnc,600 ohms balance to unbalance audio convertor with one end bnc male to connect to test and other end to connect the balanced line.,supply of ac power cord or dc adaptor with cord. if rechargeable internal battery will be charged by external battery charger, then battery charger also must be provided,supply of applicable software in cd or dvd or pen drive and hardware tools,sitc and training charges

Read more
1- push-in t-connector qst, type- festo qst-12-20, part no.- 130806, tubing od- 12mm,2- push-in t-connector qs, type- festo qs-12-20, part no.- 130690, tubing od- 12mm,3- push-in-fitting qsf-female thread with external hex, push-in fitting with female thread, qsf-1by4-12-b, type- festo qsf-g1by4-12-b, part no.- 190651, female thread g1by4, tubing od- 12mm,4- push-in l-fitting qsl- male thread with external hex, rotable. push-in l-fitting qsl-1by4-12-20, type- festo qsl-r1by4-12-20, part no.- 130734, male thread r1by4, tubing od- 12mm,5- push-in l-fitting qsl- male thread with external hex, rotable. push-in l-fitting qsl-1by2-12-20, type- festo qsl-r1by2-12-20, part no.- 130738, male thread r1by2, tubing od- 12mm,6- reducing nipple, type- festo npfc-r-g34-g12-mf, part no.- 8030313

1- push-in t-connector qst, type- festo qst-12-20, part no.- 130806, tubing od- 12mm,2- push-in t-connector qs, type- festo qs-12-20, part no.- 130690, tubing od- 12mm,3- push-in-fitting qsf-female thread with external hex, push-in fitting with female thread, qsf-1by4-12-b, type- festo qsf-g1by4-12-b, part no.- 190651, female thread g1by4, tubing od- 12mm,4- push-in l-fitting qsl- male thread with external hex, rotable. push-in l-fitting qsl-1by4-12-20, type- festo qsl-r1by4-12-20, part no.- 130734, male thread r1by4, tubing od- 12mm,5- push-in l-fitting qsl- male thread with external hex, rotable. push-in l-fitting qsl-1by2-12-20, type- festo qsl-r1by2-12-20, part no.- 130738, male thread r1by2, tubing od- 12mm,6- reducing nipple, type- festo npfc-r-g34-g12-mf, part no.- 8030313

Read more
Water meter domestic size,water meter size,ci sluice valve size,ci sluice valve size,ci nrv size,gi pipe b class size,gi plug size,greased graphite gland packing square,greased graphite gland packing square s,insertion rubber sheet size,solvent cement 50 ml packing,solvent cement 100 ml packing,hacksaw blade 24 teeth,upvc pipe sch,upvc pipe,upvc pipe,upvc pipe sch 80,upvc tee sch 80,upvc elbow sch 80,upvc coupler sch 80,upvc male adaptor brass thread,upvc union size 20 mm,upvc tee sch 80 size 25 mm,upvc elbow size 25 mm dia,upvc coupler sch 80 size 25 mm,upvc male adaptor brass thread size 25 mm,upvc union,upvc elbow,upvc coupler,upvc male adaptor brass thread,upvc female adaptor brass thread size,upvc elbow size 50 mm,upvc coupling size 50 mm dia,upvc male adaptor brass thread,upvc female adaptor brass thread,gi reducer size

Water meter domestic size,water meter size,ci sluice valve size,ci sluice valve size,ci nrv size,gi pipe b class size,gi plug size,greased graphite gland packing square,greased graphite gland packing square s,insertion rubber sheet size,solvent cement 50 ml packing,solvent cement 100 ml packing,hacksaw blade 24 teeth,upvc pipe sch,upvc pipe,upvc pipe,upvc pipe sch 80,upvc tee sch 80,upvc elbow sch 80,upvc coupler sch 80,upvc male adaptor brass thread,upvc union size 20 mm,upvc tee sch 80 size 25 mm,upvc elbow size 25 mm dia,upvc coupler sch 80 size 25 mm,upvc male adaptor brass thread size 25 mm,upvc union,upvc elbow,upvc coupler,upvc male adaptor brass thread,upvc female adaptor brass thread size,upvc elbow size 50 mm,upvc coupling size 50 mm dia,upvc male adaptor brass thread,upvc female adaptor brass thread,gi reducer size

Read more
Ac circuit breaker 16a, 3 pole (type-14) with aux. contact 2 no to spec no.- clw/es/3/0096 [alt.-l]. (one set comprises of 02 nos. of ac circuit breakers along with 02 nos of aux.contact 2 no.), ref.-no. ng125h3p16 ac-18724 + aux. con. 19071

Ac circuit breaker 16a, 3 pole (type-14) with aux. contact 2 no to spec no.- clw/es/3/0096 [alt.-l]. (one set comprises of 02 nos. of ac circuit breakers along with 02 nos of aux.contact 2 no.), ref.-no. ng125h3p16 ac-18724 + aux. con. 19071

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise