Particulars | Details |
---|---|
Title |
Work Of Cleaning, Dressing, Providing And Fixing Of Power Contractor, Mcb, Auxiliary Contact, And All Connecting Cable Of Marshaling Box As Per Site Requirement Of Fan And Associated Auxiliary Circuits Of 40 Mva T/F Ii (Accurate Make)
|
Description |
Work Of Cleaning, Dressing, Providing And Fixing Of Power Contractor, Mcb, Auxiliary Contact, And All Connecting Cable Of Marshaling Box As Per Site Requirement Of Fan And Associated Auxiliary Circuits Of 40 Mva T/F Ii (Accurate Make)
|
Organisation | UP Power Transmission Corp.Ltd (Operation) | State Govt. and UT |
Tender Id | 2025_UPTCL_1017201_1 |
Reference Number |
E-TENDER No.06-ETD(D)/ 2024-25 |
Tender Fee | 590 |
EMD | 2000 |
Tender Value | |
Place | 132 KV SUB STATION DEORIA |
Link | https://etender.up.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=1833565 |
Start Date | March 12, 2025 23:30 |
End Date |
18/03/2025 ( Expired 35 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Replacement of gasket and centrifuging of 132/33 kv 40 mva t/f-ii (bbl make) installed at 132 kv s/s dalla under etd, robertsganj.
Replacement of gasket and centrifuging of 132/33 kv 40 mva t/f-ii (bbl make) installed at 132 kv s/s dalla under etd, robertsganj.
Read moreWork of cleaning, dressing, providing and fixing of power contractor, mcb, auxiliary contact, and all connecting cable of marshaling box as per site requirement of fan and associated auxiliary circuits of 40 mva t/f-ii (accurate make)
Work of cleaning, dressing, providing and fixing of power contractor, mcb, auxiliary contact, and all connecting cable of marshaling box as per site requirement of fan and associated auxiliary circuits of 40 mva t/f-ii (accurate make)
Read more4-pole contactors for controlling power circuits (k0l & k02) up to 690 v ac and 440v dc. a50-40-00 380-400v 50hz/400-415v 60hz abb: product id: lsbl35l20lr8400 along with ca5-22e auxiliary contact block abb product id: lsbn0l0040rl022 and rv5/133 surge suppressor abb: sbn0500l0rl 001. required make: abb, siemens, l&t or schneider as per edts.355.
For complete deion and other details, please refer to tender
Read moreWork of loading, safe carriage, unloading of 100 mva t/f from lucknow to pahadi (chitrakoot) and its erection alongwith associated all dismantling work including all supply at 220 kv s/s pahadi (chitrakoot) under etd banda.
Work of loading, safe carriage, unloading of 100 mva t/f from lucknow to pahadi (chitrakoot) and its erection alongwith associated all dismantling work including all supply at 220 kv s/s pahadi (chitrakoot) under etd banda.
Read more4-pole contactors for controlling power circuits (k0l & k02) up to 690 v ac and 440v dc. a50-40-00 380-400v 50hz/400-415v 60hz abb: product id: lsbl35l20lr8400 along with ca5-22e auxiliary contact block abb product id: lsbn0l0040rl022 and rv5/133 surge suppressor abb: sbn0500l0rl 001. required make: abb, siemens, l&t or schneider as per edts.355.
For complete deion and other details, please refer to tender
Read moreDismantling, shifting of old 40 mva transformer (bharat bijlee make) and erection of 63 mva transformer with all associated work at 132 kv sub- station chandauli
Dismantling, shifting of old 40 mva transformer (bharat bijlee make) and erection of 63 mva transformer with all associated work at 132 kv sub- station chandauli
Read moreWork of complete erection, installation of 132/33 kv, 40 mva t/f and other associated works like dismaintling of 20 mva t/f etc. at 132 kv s/s panwari under etd hamirpur.
Work of complete erection, installation of 132/33 kv, 40 mva t/f and other associated works like dismaintling of 20 mva t/f etc. at 132 kv s/s panwari under etd hamirpur.
Read moreSupply of 3 pole power contactor, rating: 750 amps, 1000v ac, coil voltage: 250-500v ac/dc along with auxiliary contact 2no 2nc, similar and equivalent in all respect dimensions to abb make type: af-750-30-11 and contact type cal-18-11. make: abb/siemens/schneider suitable for sbc-2 unit of eog lhb power car
For complete deion and other details, please refer to tender
Read moreMotor protection circuit breaker (mpcb) overload released range 40-63 a at 415v ac, 50hz. of star delta for radiator fan motor fitted in lhb power car conforming to rcf specification no. edts 114, rev-b similar to m/s siemens part no. 3vu1640-ls00. accepted make: siemens/abb/schneider/l&t. note: supplier should be oem or their authorized dealer & in case of authorized dealer, dealership certificate should be submitted during tender bidding.
For complete deion and other details, please refer to tender
Read moreMpcb for ventilation fan unit 1 & 2, thermal release range (rated current) : 2.5-4.0 a, class 10, breaking capacity : 50 ka, 3 pole, rated voltage 415 v ac, 1 no 1 nc auxiliary contact block as per rdso common bill of material letter no el/7.108/mssbc dated 17.09.21, make- abb catalogue no ms 116-4 / legrand / eaton / schneider catalogue no gv2me08gvae11/ l&t catalogue no st418960000/ siemens catalogue no 3rv2011 1ea103rv2901-1e only.
For complete deion and other details, please refer to tender