Tender Details
Particulars | Details |
---|---|
Title |
(1) Repairing And Maintenance Of Ngef 6.6 Kv 1250 Amp.Mocb Sl.No.4811211241 Of Kc 2 Pit Sub Station Katras Area.(2) Dismantling And Installation Of Transformer 500 Kv/440 Volt And Dismantling And Installation 400 A Ht And Lt Switch At R.H.K Central Ho
|
Description |
(1) Repairing And Maintenance Of Ngef 6.6 Kv 1250 Amp.Mocb Sl.No.4811211241 Of Kc 2 Pit Sub Station Katras Area.(2) Dismantling And Installation Of Transformer 500 Kv/440 Volt And Dismantling And Installation 400 A Ht And Lt Switch At R.H.K Central Ho
|
Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
Tender Id | 2024_BCCL_324151_1 |
Reference Number |
BCCL/KA-IV/ENM/E-TEN/24-25/212 DATE- 25.12.2024 |
Tender Fee | 0 |
EMD | 2200 |
Tender Value | |
Place | 33KV/6.6KV KC2 PIT SUB-STATION |
Link | https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=336004 |
Start Date | December 25, 2024 21:30 |
End Date |
08/01/2025 ( Expired 151 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Repairs and maint of 11 kv ht cable, switch gear, ring main unit, master relay, metering equipment, 11 kv/0.433kv distribution transformer, compact sub station including re-winding, oil filtering, painting, stud conservators and connected works
Repairs and maint of 11 kv ht cable, switch gear, ring main unit, master relay, metering equipment, 11 kv/0.433kv distribution transformer, compact sub station including re-winding, oil filtering, painting, stud conservators and connected works
Read more(1) supply and installation of chemical earth pit of kantapahri sub-station , under katras area.(2) supply and installation of lightning arrestor with chemical earth pit at ramkanali filter plant -02
(1) 
 supply 
 and 
 installation of chemical 
 earth pit of kantapahri 
 sub-station , under katras 
 area.(2) 
 supply 
 and 
 installation of lightning 
 arrestor with chemical 
 earth pit at ramkanali 
 filter 
 plant -02
Read moreRepairing of 02 no gec make 315 kva 3.3 kv to 570 volt an-an type of cooling tran switch unit installed at different panel sub-station for 315 kv transformer sr. no. missing of bhadra 7 8 mine
Repairing of 02 no gec make 315 kva 3.3 kv to 570 volt an-an type of cooling tran switch unit installed at different panel sub-station for 315 kv transformer sr. no. missing of bhadra 7 8 mine
Read moreComplete repairing / rewinding of 500 kva lighting transformer 3.3 kv / 415 volt, s/n 2800022343, 46/656 amp, make aeg/ngef installed at rest house substation of sawang washery.
Complete repairing / rewinding of 500 kva lighting transformer 3.3 kv / 415 volt, s/n 2800022343, 46/656 amp, make aeg/ngef installed at rest house substation of sawang washery.
Read more(1) erection of 3.3 kv over head line installation of 3000 gpm pump at ampl sump for fire fighting of ampl coal dump akwmc,ocp katras area.(2) dismantling and diversion of 6.6 kv power feeder for placement
(1) erection of 3.3 kv over 
 head line installation of 
 3000 gpm pump at ampl 
 sump for fire fighting of 
 ampl coal dump akwmc,ocp 
 katras 
 area.(2) 
 dismantling and diversion 
 of 6.6 kv power feeder for 
 placement
Read moreProviding and fixing air break switch, drop out fuse in ht side and outdoor cable termination work in lt side with other accessories work of two nos. transformer installed near pit office and shivpur railway siding and provision of earth leakage rela
Providing and fixing air break switch, drop out fuse in ht side and outdoor cable termination work in lt side with other accessories work of two nos. transformer installed near pit office and shivpur railway siding and provision of earth leakage rela
Read more(a)complete repairing of 3.3kv, 400amps vcb switch andrew yule make type nflp, sl.no.3837 and (b)repairing of bucholz relay wti and oti protective device 11kv/3.3kv transformer for controlling of f.n.-2 upper side s/s of mocp f/b of amp colliery.
(a)complete repairing of 3.3kv, 400amps vcb switch andrew yule make type nflp, sl.no.3837 and (b)repairing of bucholz relay wti and oti protective device 11kv/3.3kv transformer for controlling of f.n.-2 upper side s/s of mocp f/b of amp colliery.
Read moreRepairing of (a) 11kv, 600a, gec make ocb switch sl.no.-2817 and (b) 6.6kv,400a gec make ocb switch sl. no.-m-164 for controlling of 11kv/6.6kv transformer at sadbhavna substation under muraidih, amp colliery.
Repairing of (a) 11kv, 600a, gec make ocb switch 
 sl.no.-2817 and (b) 6.6kv,400a gec make ocb 
 switch sl. no.-m-164 for controlling of 11kv/6.6kv 
 transformer at sadbhavna substation under 
 muraidih, amp colliery.
Read more(1) dismantling erection and repairing of 440 volt over head line from 6 pit to habitation near river side,agkcc,ka (2) repairing/maintenance of over head line 220 volt at 6 pit kcc and behind railway culvert,agkcc.(3) repairing and maintenance
(1) dismantling erection and repairing of 440 volt over head line from 6 pit to habitation near river side,agkcc,ka (2) repairing/maintenance of over head line 220 volt at 6 pit kcc and behind railway culvert,agkcc.(3) repairing and maintenance
Read more((1) dismantling and erection of 440 volt over head line lighting line near bhumi mines departmental haul road at akwmc,ocp under katras area.(2) erection of 440 volt over haed line for welding arrangment at ocp site in ampl section of akwmc.
((1) dismantling and erection of 440 volt over head line lighting line near bhumi mines departmental haul road at akwmc,ocp under katras area.(2) erection of 440 volt over haed line for welding arrangment at ocp site in ampl section of akwmc.
Read moreof your Industry type