| Particulars | Details |
|---|---|
| Title |
Survey, Repair/Replacement Including Supply Of Materials, Maintenance, Performance Monitoring And Sustenance Of Steam Trap System At Mathura Refinery.
|
| Description |
Survey, Repair/Replacement Including Supply Of Materials, Maintenance, Performance Monitoring And Sustenance Of Steam Trap System At Mathura Refinery.
|
| Organisation | IndianOil | Central Govt. Ministry/Department |
| Tender Id | 2024_MR_181370_1 |
|
Reference Number |
MRCC24H052 |
| Tender Fee | 0 |
| EMD | 79952 |
| Tender Value | - |
| Place | Mathura Refinery |
| Link |
View Original Tender Notice
https://iocletenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=191662 |
| Start Date | October 24, 2024 22:30 |
| End Date |
Expired
28/12/2024
Expired 659 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Custom bid for services - rpnc265046 rate contract for survey & continuous monitoring of steam trap network at iocl-panipat naphtha cracker, panipat
Custom bid for services - rpnc265046 rate contract for survey & continuous monitoring of steam trap network at iocl-panipat naphtha cracker, panipat
Read moreSr. no. 1 steam trap as spare for one to one replacement of existing equipment of following specification model pt 17 diagram no pe 211 07 r0 size 25 nb as per specification attached,sr. no. 2 steam trap as spare for one to one replacement of existing equipment of following specification model pt 17 diagram no pe 211 07 r0 size 15 nb as per specification attached,sr. no. 3 steam trap as spare for one to one replacement of existing equipment of following specification model pt 62 s 10 diagram no pe 211 04 r0 size 50 nb as per specification attached,sr. no. 4 steam trap as spare for one to one replacement of existing equipment of following specification model pt 62 s 4.5 diagram no pe 211 06 r0 size 25 nb as per specification attached,sr. no. 5 steam trap as spare for one to one replacement of existing equipment of following specification model pt 62 s 4.5 diagram no pe 211 05 r0 size 50 nb as per specification attached,sr. no. 6 steam trap as spare for one to one replacement of existing equipment of following
Sr. no. 1 steam trap as spare for one to one replacement of existing equipment of following specification model pt 17 diagram no pe 211 07 r0 size 25 nb as per specification attached,sr. no. 2 steam trap as spare for one to one replacement of existing equipment of following specification model pt 17 diagram no pe 211 07 r0 size 15 nb as per specification attached,sr. no. 3 steam trap as spare for one to one replacement of existing equipment of following specification model pt 62 s 10 diagram no pe 211 04 r0 size 50 nb as per specification attached,sr. no. 4 steam trap as spare for one to one replacement of existing equipment of following specification model pt 62 s 4.5 diagram no pe 211 06 r0 size 25 nb as per specification attached,sr. no. 5 steam trap as spare for one to one replacement of existing equipment of following specification model pt 62 s 4.5 diagram no pe 211 05 r0 size 50 nb as per specification attached,sr. no. 6 steam trap as spare for one to one replacement of existing equipment of following
Read moreHealth and performance monitoring of reciprocating compressors at mathura refinery
Health and performance monitoring of reciprocating compressors at mathura refinery
Read moreCustom bid for services - rprc246360 steam leak and steam trap network survey and monitoring at prp
Read more
Dre224s258 service contract for steam trap system survey, continuous monitoring and rectification including supply of traps and spares in digboi refinery.
Dre224s258 service contract for steam trap system survey, continuous monitoring and rectification including supply of traps and spares in digboi refinery.
Read moreConducting mill wide steam trap survey audit.
Conducting mill wide steam trap survey audit.
Read moreof your Industry type