Main Contactor For Local Main Supply Against K43, Current Rating 110 Amp, 4 Pole, 415 Vac, Coil Voltage 380 415 V Ac 50 Hz With 2 Nc Aux Contact Along With Surge Suppresor For Lhb Type Ac Coaches Etc.
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106242957 |
|
Reference Number |
AD235192A |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Kolkata |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/012024/106242957/viewNitPdf_4453142.pdf |
| Start Date | January 12, 2024 18:11 |
| End Date |
Expired
24/01/2024
Expired 997 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Starter delta starter contactor 415 vac 32a, 50hz motor rating 15kw with auxiliary contacts 1 no+ 1nc of star delta starter for radiator fan motor of lhb power caras
Starter delta starter contactor 415 vac 32a, 50hz motor rating 15kw with auxiliary contacts 1 no+ 1nc of star delta starter for radiator fan motor of lhb power caras
Read moreFeeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Read moreContactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Read moreHermitically sealed scroll compressor, suitable for r-407 c refrigerant gas, working on 415 vac, 50 hz, conforming to rdso specification no. rdso/pe/spec/ac/0061/2005(rev-1). make and model should be rdso approved. note: (i) emerson part no. zr 61 kce tfd522 / danfoss part no. mlz038t4 or any other make and model of equipment/component can only be considered with prior approval of rdso.
Hermitically sealed scroll compressor, suitable for r-407 c refrigerant gas, working on 415 vac, 50 hz, conforming to rdso specification no. rdso/pe/spec/ac/0061/2005(rev-1). make and model should be rdso approved. note: (i) emerson part no. zr 61 kce tfd522 / danfoss part no. mlz038t4 or any other make and model of equipment/component can only be considered with prior approval of rdso.
Read moreAir circuit breaker (acb) suitable for lhb power car of system voltage-750 v, capacity-800 amp, breaking capacity-50ka, frequency-50 hz, 3 pole mf (with inbuilt uv protection, thermal, magnetic release), 6 no + 6 nc aux contact block and draw-out acbs terminal adaptors) similar to l&t make acb type: cn-cs 800c conforming to rcf specification no: edts 103, rev-d, am-07 or latest, make- lauritz knudsen formerly l&t/abb/ge only.
Air circuit breaker (acb) suitable for lhb power car of system voltage-750 v, capacity-800 amp, breaking capacity-50ka, frequency-50 hz, 3 pole mf (with inbuilt uv protection, thermal, magnetic release), 6 no + 6 nc aux contact block and draw-out acbs terminal adaptors) similar to l&t make acb type: cn-cs 800c conforming to rcf specification no: edts 103, rev-d, am-07 or latest, make- lauritz knudsen formerly l&t/abb/ge only.
Read morePower contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e
Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e
Read moreFeeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de
Feeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de
Read moreContactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Read more2 core x one and half sq mm pvc insulated copper conductor flexible pvc sheathed cable, 1100 volt,4 sq mm twin core aluminium cable,pvc insulated copper wire thrird fourth square mm , 1 core,copper wire one square mm single core, frlsh, 90mtr in roll,copper wire one and half square mm single core, frlsh, 90mtr in roll,copper wire two and half sq mm single core, frlsh, 90mtr in roll,11kv goab switch vertical type complete with all accessories suitable for 200amps.,11kv triple pole do fuse set,changeover switch 200a. 415v,switch fuse unit with enclosure, rating 200a,single pole mcb of b series 16 a,240 v, 50 hz, 10 ka,240 v, 32amp, singal pole with neutral spn, miniature circuit breaker mcb,240 v, 63amp, singal pole with neutralspn, miniature circuit breaker mcb,mccb 3p 415v 32a,mccb 32 a 4 pole 415 v,mccb 415v 63amp or mccb 63a, 3 pole,four pole mcb 63a, 415v,mccb 100 amp, three pole,mccb, 4 pole, 100a, 415v,mccb 150a,3 pole,mccb 200 amp, three pole,mccb, 4 pole, 200a, 415v,power point combined switch and sock
2 core x one and half sq mm pvc insulated copper conductor flexible pvc sheathed cable, 1100 volt,4 sq mm twin core aluminium cable,pvc insulated copper wire thrird fourth square mm , 1 core,copper wire one square mm single core, frlsh, 90mtr in roll,copper wire one and half square mm single core, frlsh, 90mtr in roll,copper wire two and half sq mm single core, frlsh, 90mtr in roll,11kv goab switch vertical type complete with all accessories suitable for 200amps.,11kv triple pole do fuse set,changeover switch 200a. 415v,switch fuse unit with enclosure, rating 200a,single pole mcb of b series 16 a,240 v, 50 hz, 10 ka,240 v, 32amp, singal pole with neutral spn, miniature circuit breaker mcb,240 v, 63amp, singal pole with neutralspn, miniature circuit breaker mcb,mccb 3p 415v 32a,mccb 32 a 4 pole 415 v,mccb 415v 63amp or mccb 63a, 3 pole,four pole mcb 63a, 415v,mccb 100 amp, three pole,mccb, 4 pole, 100a, 415v,mccb 150a,3 pole,mccb 200 amp, three pole,mccb, 4 pole, 200a, 415v,power point combined switch and sock