Tender Details
Particulars | Details |
---|---|
Title |
Supply And Installation Of 02 Nos. Of Ngr 3.3 Kv, 10 Amp , 190 Ohms For 02 Nos. Of 3 Mva Transformer 11 Kv/3.3 Kv Transformers At Main Sub Station Of Gidi C Colliery Along With Maintenance , Repairing And Painting Of 3.3 Kv Overhead Line Poles At Gidi C
|
Description |
Supply And Installation Of 02 Nos. Of Ngr 3.3 Kv, 10 Amp , 190 Ohms For 02 Nos. Of 3 Mva Transformer 11 Kv/3.3 Kv Transformers At Main Sub Station Of Gidi C Colliery Along With Maintenance , Repairing And Painting Of 3.3 Kv Overhead Line Poles At Gidi C
|
Organisation | Central Coalfields Limited | Public Sector Undertakings |
Tender Id | 2025_CCL_329469_1 |
Reference Number |
PE(EnM)/GDC/eNIT/2024-25/20 Date 18.02.2025 |
Tender Fee | 0 |
EMD | 30200 |
Tender Value | |
Place | Gidi-C Colliery |
Link | https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=341496 |
Start Date | February 19, 2025 16:30 |
End Date |
28/02/2025 ( Expired 51 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
(a). repairing of 3.3kv, 630a, vcb, ctr 600/300/5a, make-pce, sl.no.-05/hmv/132 installed at main sub-station of gvp phase-ii ocp, (b). repairing of 3.3kv vcb, make-pce, 630a, sl.no.-05/hmv/131 of secondary switch at 3mva, 11kv/3.3kv transformer of g
(a). repairing of 3.3kv, 630a, vcb, ctr 600/300/5a, make-pce, sl.no.-05/hmv/132 installed at main sub-station of gvp phase-ii ocp, (b). repairing of 3.3kv vcb, make-pce, 630a, sl.no.-05/hmv/131 of secondary switch at 3mva, 11kv/3.3kv transformer of g
Read moreRepairing, maintenance along with providing and fixing of cts, pts, mocbs with maintenance of 33 kv bus-bar system and control relay panel at main sub station of nandira colliery.
Repairing, maintenance along with providing and fixing of cts, pts, mocbs with maintenance of 33 kv bus-bar system and control relay panel at main sub station of nandira colliery.
Read moreWork of attending breakdowns, construction, re-arrangement, shifting, replacement/repairing of damaged poles etc. of 33kv and 11kv o/h and u/g lines and sub-station under the area of assistant engineer-ist, 33 kv and electrical safety, kesco kanpur
Work of attending breakdowns, construction, re-arrangement, shifting, replacement/repairing of damaged poles etc. of 33kv and 11kv o/h and u/g lines and sub-station under the area of assistant engineer-ist, 33 kv and electrical safety, kesco kanpur
Read moreAttending of transformer oil leakage and painting work in 63 mva transformer at 132 kv sub station azadnagar under etd-i kanpur
Attending of transformer oil leakage and painting work in 63 mva transformer at 132 kv sub station azadnagar under etd-i kanpur
Read moreRepairing and maintenance of transformers (ratings 5mva 33/6.6 kv, 3.15 mva, 33/6.6kv and 2mva 33/3.3kv) and filtration of transformer oil of block-b project.
Repairing and maintenance of transformers (ratings 5mva 33/6.6 kv, 3.15 mva, 33/6.6kv and 2mva 33/3.3kv) and filtration of transformer oil of block-b project.
Read moreErection of 3.3 kv o/h line from kali mandir sub-station to pumping statio of hired patch-c and dismantling and erection of 11kv o/h line for clearing working area of proposed patch-c of abg colliery under govindpur area
Erection of 3.3 kv o/h line from kali mandir sub-station to pumping statio of hired patch-c and dismantling and erection of 11kv o/h line for clearing working area of proposed patch-c of abg colliery under govindpur area
Read moreAdding of 01 no. 160 mva transformer along with shifting and complete erection of 160 mva transformer with construction of 01 no. 220 kv bay and 02 nos. 132 kv bay and repair of emulsifire system with all associated work
Adding of 01 no. 160 mva transformer along with shifting and complete erection of 160 mva transformer with construction of 01 no. 220 kv bay and 02 nos. 132 kv bay and repair of emulsifire system with all associated work
Read moreSupply and fixing of ngr 3.3kv 10 amp, 190 ohms for 3 nos., 1 mva, 11kv/3.3kv (2 nos.) and 1.6 mva, 11kv/3.3 kv (01 no.) power transformer installed at main and banwar substation at topa project under kuju area.
Supply and fixing of ngr 3.3kv 10 amp, 190 ohms for 3 nos., 1 mva, 11kv/3.3kv (2 nos.) and 1.6 mva, 11kv/3.3 kv (01 no.) power transformer installed at main and banwar substation at topa project under kuju area.
Read moreMaintenance and repairing at site of buchloz relay alarm bell system of 02 nos of 1mva,11kv/3.3kv power transformer at main substation and mine substation of karma project under kuju area.
Maintenance and repairing at site of buchloz relay alarm bell system of 02 nos of 1mva,11kv/3.3kv power transformer at main substation and mine substation of karma project under kuju area.
Read moreInstallation of 10mva, 33kv/11kv transformer, sl. no. ks/1000/23/9, make k sambhav powertronics with differential protection and its accessories at 22.5 mva, 33kv/11kv-3.3kv old sub-station under kdh ocp, nk area
Installation of 10mva, 33kv/11kv transformer, sl. no. ks/1000/23/9, make k sambhav powertronics with differential protection and its accessories at 22.5 mva, 33kv/11kv-3.3kv old sub-station under kdh ocp, nk area