Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Complete Overhauling Of Electroteknica Vcb,11kv,400 A, Sl.No. Sgi2322 At Bilbera Substation Under Govindpur Area.
|
| Description |
Complete Overhauling Of Electroteknica Vcb,11kv,400 A, Sl.No. Sgi2322 At Bilbera Substation Under Govindpur Area.
|
| Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
| Tender Id | 2024_BCCL_302758_1 |
|
Reference Number |
BCCL/GA-III/AM (EnM) E-TENDER/2023-24/313 |
| Tender Fee | 0 |
| EMD | 505 |
| Tender Value | - |
| Place | Govindpur Area Office |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=313630 |
| Start Date | February 29, 2024 16:30 |
| End Date |
Expired
11/03/2024
Expired 947 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
11kv switchboards for water works substation 9vcb,installation, testing , commissioning of 11kv switchboards for water works substation 09 vcb,11kv switchboards for sector4 substation,installation, testing , commissioning of 11kv switchboards for sector4 substation,11kv switchboards for sector7 substation,nstallation, testing , commissioning of 11kv switchboards for sector7 substation.,11kv switchboards for adbuilding substation,installation, testing , commissioning of 11kv switchboards for adbuilding substation,11kv switchboards for workshop area substation,installation, testing , commissioning of 11kv switchboards for workshop area substation,11kv switchboards for lab area substation,installation, testing , commissioning of 11kv switchboards for lab area substation
11kv switchboards for water works substation 9vcb,installation, testing , commissioning of 11kv switchboards for water works substation 09 vcb,11kv switchboards for sector4 substation,installation, testing , commissioning of 11kv switchboards for sector4 substation,11kv switchboards for sector7 substation,nstallation, testing , commissioning of 11kv switchboards for sector7 substation.,11kv switchboards for adbuilding substation,installation, testing , commissioning of 11kv switchboards for adbuilding substation,11kv switchboards for workshop area substation,installation, testing , commissioning of 11kv switchboards for workshop area substation,11kv switchboards for lab area substation,installation, testing , commissioning of 11kv switchboards for lab area substation
Read moreFor repairing and overhauling of 02 nos.6.6kv,vcb switch(i)6.6kv.630a mine line make-vcb sl.no.sa 697 asset no.sbc/24(ii)6.6kv,400a opg power system pvt.make-vcb sl.no.v/149/23-27 asset no.sbc/22 installed at chp central pool substation under asbnc
For repairing and overhauling of 02 nos.6.6kv,vcb switch(i)6.6kv.630a mine line make-vcb sl.no.sa 697 asset no.sbc/24(ii)6.6kv,400a opg power system pvt.make-vcb sl.no.v/149/23-27 asset no.sbc/22 installed at chp central pool substation under asbnc
Read moreFor repairing of incomer 400a,6.6kv, ocb switch sl.no. bsp/switch/06 make ferguson at ekra substation basdeopur colliery under sijua area
For repairing of incomer 400a,6.6kv, ocb switch sl.no. bsp/switch/06 make ferguson at ekra substation basdeopur colliery under sijua area
Read morePreventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Preventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Read moreMaintenance and reconditioning of 2 nos. vcb (11kv and 6.6kv, pce make), 2 nos. ocb switch (11kv, 800 amp, gec make), sf6 abb make breaker (33kv, 1250 amp), maintenance of ct, and repairing of 11kv capacitor bank control panel at central substation
Maintenance and reconditioning of 2 nos. vcb (11kv and 6.6kv, pce make), 2 nos. ocb switch (11kv, 800 amp, gec make), sf6 abb make breaker (33kv, 1250 amp), maintenance of ct, and repairing of 11kv capacitor bank control panel at central substation
Read moreComplete re-winding and re-insulation of 1 no. of 200 kva flp tsu, type t3sob200/6 with sl.no. 679573, 1 no. of 315 kva flp tsu, type t3sb315/6 with sl.no. 79154399 for the main substation, moonidih
Complete re-winding and re-insulation of 1 no. of 200 kva flp tsu, type t3sob200/6 with sl.no. 679573, 1 no. of 315 kva flp tsu, type t3sb315/6 with sl.no. 79154399 for the main substation, moonidih
Read moreEl.d.c.nosmii/p1/3680/2026 overhauling 4nos 1000 kva oil type transformer including filtration top up of new tr oil 1 no of earth fault relay master relay available in 11kv vcb accessories transport charges available at amma kalaignar maaligai
Overhauling of 4 nos 1000 kva oil type transformer including filtration and top up of new tr oil 1 no of earth fault relay master relay available in the 11 kv vcb accessories transport charges available at amma maaligai muthamizh arignar kalaign
Read moreAnnual maintenance contract (amc) of 01 no substation i/c (integrated circuit) of 11kv ht and lt line and ht metering room contains 11 nos 800 amp 11 kv ht vcb, 6 nos 1600 amp lt acbs and 4 no 1000 amp transformer at gc, crpf jalandhar.
Annual maintenance contract (amc) of 01 no substation i/c (integrated circuit) of 11kv ht and lt line and ht metering room contains 11 nos 800 amp 11 kv ht vcb, 6 nos 1600 amp lt acbs and 4 no 1000 amp transformer at gc, crpf jalandhar.
Read moreFor complete repairing and overhauling of ocb, sd -15 make kilburn switch 550v,150a, asst. no. arn/72 sl.no.08595 4 pit loyabad (ii)and repairing of 120 hp,550v,star delta starter, a.t.s type, amba speed make,sl.no.a-223-97 controlling of submersible
For complete repairing and overhauling of ocb, sd -15 make kilburn switch 550v,150a, asst. no. arn/72 sl.no.08595 4 pit loyabad (ii)and repairing of 120 hp,550v,star delta starter, a.t.s type, amba speed make,sl.no.a-223-97 controlling of submersible
Read more(i)for maintenance of one no.1 mva 6.6kv/550v transformer installed at loyabad colliery make-ece,asset sl.no.arn/14 lbc(ii)complete rewinding and overhauling of a 750 kva power transformer 6.6kv/550v at 5 pit substation of lbc make-ece asset.no.loy/e
(i)for maintenance of one no.1 mva 6.6kv/550v transformer installed at loyabad colliery make-ece,asset sl.no.arn/14 lbc(ii)complete rewinding and overhauling of a 750 kva power transformer 6.6kv/550v at 5 pit substation of lbc make-ece asset.no.loy/e