Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Rep. Of (A) Hoist Brakes 03 Sets (B) Crowd Clutch 03 Sets (C) Swing Brakes 06 Sets (D) Hoist Blower 03 Nos. (E) Swing Blower 06 Nos. (F) Body Fan 09 Nos. And (G) Hot Shrink Tubing In 09 Nos. Joints In Trailing Cables In Ekg Shovels Sl. No.581,592,596
|
| Description |
Rep. Of (A) Hoist Brakes 03 Sets (B) Crowd Clutch 03 Sets (C) Swing Brakes 06 Sets (D) Hoist Blower 03 Nos. (E) Swing Blower 06 Nos. (F) Body Fan 09 Nos. And (G) Hot Shrink Tubing In 09 Nos. Joints In Trailing Cables In Ekg Shovels Sl. No.581,592,596
|
| Organisation | Central Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2025_CCL_325182_1 |
|
Reference Number |
PE(X)/JOCP/NIT/24-25/20 Dated - 08.01.2025 |
| Tender Fee | 0 |
| EMD | 4300 |
| Tender Value | |
| Place | Jharkhand OCP |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=337081 |
| Start Date | January 08, 2025 19:30 |
| End Date |
Expired
16/01/2025
Expired 517 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Repairing of (a). hoist brakes 03 sets (b). crowd clutch 03 sets (c). swing brakes 06 sets (d) hoist blower 03 nos. (e). swing blower 06 nos. (f). body fan 09 nos. and (g). hot shrink tubing in 09 nos. joints in trailing cables in ekg shovels sl. no.
Repairing of (a) hoist brakes 03 sets (b) crowd clutch 03 sets (c) swing brakes 06 sets (d) hoist blower 03 nos. (e) swing blower 06 nos. (f). body fan 09 nos. and (g) hot shrink tubing in 09 nos. joints in trailing cables in ekg shovels sl. no.581,5
Read moreRepairing of 03 nos. hoist blower, 06 nos. swing blower and 09 nos. body fans alongwith hot shrink tubing of 09 nos. joints of trailing cables in ekg shovels sl. no. 581, 592 and 596 of jharkhand ocp.
Repairing of 03 nos. hoist blower, 06 nos. swing blower and 09 nos. body fans alongwith hot shrink tubing of 09 nos. joints of trailing cables in ekg shovels sl. no. 581, 592 and 596 of jharkhand ocp.
Read moreRepairing of hoist brakes 03 sets, crowd clutch 03 sets and swing brakes 06 sets in ekg shovels sl. no. 581, 592 and 596 of jharkhand ocp.
Repairing of hoist brakes 03 sets, crowd clutch 03 sets and swing brakes 06 sets in ekg shovels sl. no. 581, 592 and 596 of jharkhand ocp.
Read moreRepairing / rewinding of 04 nos. , 1.1kw, 220/440v swing, crowd and body fan blower motor of ekg rope shovel, sl. no. 591 of kdh project.
Repairing / rewinding of 04 nos. , 1.1kw, 220/440v swing, crowd and body fan blower motor of ekg rope shovel, sl. no. 591 of kdh project.
Read moreRepairing of 03 nos. float magnetic amplifier units (hoist, crowd and swing/propel) for ekg shovels and repairing of float isolator and vcb assembly for ekg-5a shovel at tapin north ocp, hazaribagh area.
Repairing of 03 nos. float magnetic amplifier units (hoist, crowd and swing/propel) for ekg shovels and repairing of float isolator and vcb assembly for ekg-5a shovel at tapin north ocp, hazaribagh area.
Read moreBreakup work of rep. of 04 nos 1.1 kw body blower, 01 no 1.1 kw crowd blower ,02 nos 1.1 kw swing blower ,01 no 5.5 kw compressor motor,01 no 3.7 kw hoist blower,01 no 2.2 kw hydraulic motor for ekg shovel hmb589 of dakra project,nk area.
Breakup work of rep. 
 of 04 nos 1.1 kw body blower, 01 no 1.1 kw crowd blower ,02 nos 
 1.1 kw swing blower ,01 no 5.5 kw compressor motor,01 no 3.7 kw hoist blower,01 no 2.2 kw hydraulic motor for ekg shovel hmb589 of dakra project,nk area.
Read moreRep. of 01 no. induction comp. motor, 01 no. hoist cooling motor, 04 nos. body cooling motor ,02 nos. swing cooling motor, 01 no. crowd cooling motor and rep. and jointing of trailing cable 10nos. of ekg shovel hmb-473 at nakocp of govindpur area-iii
Please refer annexure b in tender document
Read moreRepairing of lhs final drive of shovel ck300d sl.no.b756 and repairing with rewinding of body fan motor (1.1kw/220v) 04 nos, swing blower motor (1.1kw/220v) 02 nos, crowd blower motor (1.1kw/220v) 01 no and hoist blower motor of (3.6kw/220v) 01 no fo
Repairing of lhs final drive of shovel ck300d sl.no.b756 and repairing with rewinding of body fan motor (1.1kw/220v) 04 nos, swing blower motor (1.1kw/220v) 02 nos, crowd blower motor (1.1kw/220v) 01 no and hoist blower motor of (3.6kw/220v) 01 no fo
Read moreRepairing of lhs final drive of shovel ck300d sl.no.b756 and repairing with rewinding of body fan motor (1.1kw/220v) 04 nos, swing blower motor (1.1kw/220v) 02 nos, crowd blower motor (1.1kw/220v) 01 no and hoist blower motor of (3.6kw/220v) 01 no fo
Repairing of lhs final drive of shovel ck300d sl.no.b756 and repairing with rewinding of body fan motor (1.1kw/220v) 04 nos, swing blower motor (1.1kw/220v) 02 nos, crowd blower motor (1.1kw/220v) 01 no and hoist blower motor of (3.6kw/220v) 01 no fo
Read moreRepairing of motor protection relay, vacuum circuit breaker, vacuum contactor, ht fuse, rewinding of 03 nos body fans and 01 no crowd blower, 02 nos swing blowers (1.1kw/220v each), 01 no hoist blower (3.7kw/220v, for float) and 01 nos 7.5kw compress
Repairing of motor protection relay, vacuum circuit breaker, vacuum contactor, ht fuse, rewinding of 03 nos body fans and 01 no crowd blower, 02 nos swing blowers (1.1kw/220v each), 01 no hoist blower (3.7kw/220v, for float) and 01 nos 7.5kw compress
Read moreof your Industry type