Tender Details

Particulars Details
Title
Trip Coil 30 Volt Dc Suitable For Make Shreem Vcb With Planzer And Trip Coil 30 Volt Dc Suitable For Make Stelmac Vcb
Description
Trip Coil 30 Volt Dc Suitable For Make Shreem Vcb With Planzer And Trip Coil 30 Volt Dc Suitable For Make Stelmac Vcb
Organisation Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited | State Govt. and UT
Tender Id 2025_MKVVC_401005_1
Reference
Number
GM/OnM/SPR/PUR/24-25/9196 Dated 05-02-2025
Tender Fee 885
EMD 2000
Tender Value -
Place gm office banganga parisar shivpuri
Link
View Original Tender Notice

https://mptenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=472002

Start Date February 05, 2025 23:30
End Date
Expired 13/02/2025

Expired 611 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
3tf6944-0cm7-vacuum contactor, 4no & 4nc, coil volt: 240vac,3tc4417-0bu0-dc contactor, 2no & 2nc, coil volt: 240vac.

3tf6944-0cm7-vacuum contactor, 4no & 4nc, coil volt: 240vac,3tc4417-0bu0-dc contactor, 2no & 2nc, coil volt: 240vac.

Read more
3.3kv, 18.4ka, 630a, vaccum circuit breaker trolley with 110v dc shunt trip coil, spring release coi

3.3kv, 18.4ka, 630a, vaccum circuit breaker trolley with 110v dc shunt trip coil, spring release coi

Read more
33kv trip latch assembly,33kv big cam assembly,auxiliary switch,33kv push button bracket,h.d numerical relay,ht control fuse,current transformer ct,spring charging motor for 33kv 1250a,potential transfomer pt,33kv holding catch assembly,auxiliary relay 110 to 125v,tripping solenoid coil 110v dc,master trip relay 110v dc

33kv trip latch assembly,33kv big cam assembly,auxiliary switch,33kv push button bracket,h.d numerical relay,ht control fuse,current transformer ct,spring charging motor for 33kv 1250a,potential transfomer pt,33kv holding catch assembly,auxiliary relay 110 to 125v,tripping solenoid coil 110v dc,master trip relay 110v dc

Read more
Dc ampere meter moving coil type ranges 0 -300amp without external shunt size 96 x 96mm square type class 1.5/2.5, confirm to is: 1248 make ae /indotech and yokins, suitable for battery charger of ac coaches.

Dc ampere meter moving coil type ranges 0 -300amp without external shunt size 96 x 96mm square type class 1.5/2.5, confirm to is: 1248 make ae /indotech and yokins, suitable for battery charger of ac coaches.

Read more
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21

Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21

Read more
Power contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.

Power contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.

Read more
Working and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4

Working and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4

Read more
Clear silica gel breather 8 kg,200a tpn 415v rewireable fuse main switch,400a tpn 415v rewireable fuse main switch,highly insulated discharge rod with grip,closing coil solenoid for 170 kv gcb rating 220v to 250 v dc,tripping coil shunt trip for 170 kv gcb rating 220v to 250 v dc,tinned copper braided jumper size 44 mm w into 15 mm t into 510 mm l,tinned copper braided jumper size 55 mm w into 7 mm t into 490 mm l,copper laminated jumper size 48 mm w into 14point6 mm t into 335 mm l,voltage protection relay

Clear silica gel breather 8 kg,200a tpn 415v rewireable fuse main switch,400a tpn 415v rewireable fuse main switch,highly insulated discharge rod with grip,closing coil solenoid for 170 kv gcb rating 220v to 250 v dc,tripping coil shunt trip for 170 kv gcb rating 220v to 250 v dc,tinned copper braided jumper size 44 mm w into 15 mm t into 510 mm l,tinned copper braided jumper size 55 mm w into 7 mm t into 490 mm l,copper laminated jumper size 48 mm w into 14point6 mm t into 335 mm l,voltage protection relay

Read more
Aoh (18 month) replacement kit (aal part no:4300007100/30 or latest) for single bottle vcb of m/s aal type: vcba 25.10 tr. as per rdso smino: elrs/sim/0236 rev-1, dated 31.12.2012 and amendment no.1 by rdso l no:el/3.2.61, dated 14.02.2013, suitable for motor coach of memu. one set comprising of 05 items as (annexure-a1).

Aoh (18 month) replacement kit (aal part no:4300007100/30 or latest) for single bottle vcb of m/s aal type: vcba 25.10 tr. as per rdso smino: elrs/sim/0236 rev-1, dated 31.12.2012 and amendment no.1 by rdso l no:el/3.2.61, dated 14.02.2013, suitable for motor coach of memu. one set comprising of 05 items as (annexure-a1).

Read more
Rasin cast spout assy,spout filling with connector r y b,front insulated connector r phase,front insulated connector y phase phase,front insulated connector b phase,rear insulated connector r phase,rear insulated connector y phase,rear insulated connector b phase,instrument control box,vertical isolating trolley,earth leakage relay with cbct,power converter 110 v ac to 110 v dc,tripping coil,mechanism for tripping coil,master trip relay,epoxy resin cast potential transformer 11 kv 110v,digital protection relay,epoxy resin cast current transformer,side cable box

Rasin cast spout assy,spout filling with connector r y b,front insulated connector r phase,front insulated connector y phase phase,front insulated connector b phase,rear insulated connector r phase,rear insulated connector y phase,rear insulated connector b phase,instrument control box,vertical isolating trolley,earth leakage relay with cbct,power converter 110 v ac to 110 v dc,tripping coil,mechanism for tripping coil,master trip relay,epoxy resin cast potential transformer 11 kv 110v,digital protection relay,epoxy resin cast current transformer,side cable box

Read more
Click Here to Download Dockets
of your Industry type