Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Trip Coil 30 Volt Dc Suitable For Make Shreem Vcb With Planzer And Trip Coil 30 Volt Dc Suitable For Make Stelmac Vcb
|
| Description |
Trip Coil 30 Volt Dc Suitable For Make Shreem Vcb With Planzer And Trip Coil 30 Volt Dc Suitable For Make Stelmac Vcb
|
| Organisation | Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited | State Govt. and UT |
| Tender Id | 2025_MKVVC_401005_1 |
|
Reference Number |
GM/OnM/SPR/PUR/24-25/9196 Dated 05-02-2025 |
| Tender Fee | 885 |
| EMD | 2000 |
| Tender Value | - |
| Place | gm office banganga parisar shivpuri |
| Link |
View Original Tender Notice
https://mptenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=472002 |
| Start Date | February 05, 2025 23:30 |
| End Date |
Expired
13/02/2025
Expired 611 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
3tf6944-0cm7-vacuum contactor, 4no & 4nc, coil volt: 240vac,3tc4417-0bu0-dc contactor, 2no & 2nc, coil volt: 240vac.
3tf6944-0cm7-vacuum contactor, 4no & 4nc, coil volt: 240vac,3tc4417-0bu0-dc contactor, 2no & 2nc, coil volt: 240vac.
Read more3.3kv, 18.4ka, 630a, vaccum circuit breaker trolley with 110v dc shunt trip coil, spring release coi
3.3kv, 18.4ka, 630a, vaccum circuit breaker trolley with 110v dc shunt trip coil, spring release coi
Read more33kv trip latch assembly,33kv big cam assembly,auxiliary switch,33kv push button bracket,h.d numerical relay,ht control fuse,current transformer ct,spring charging motor for 33kv 1250a,potential transfomer pt,33kv holding catch assembly,auxiliary relay 110 to 125v,tripping solenoid coil 110v dc,master trip relay 110v dc
33kv trip latch assembly,33kv big cam assembly,auxiliary switch,33kv push button bracket,h.d numerical relay,ht control fuse,current transformer ct,spring charging motor for 33kv 1250a,potential transfomer pt,33kv holding catch assembly,auxiliary relay 110 to 125v,tripping solenoid coil 110v dc,master trip relay 110v dc
Read moreDc ampere meter moving coil type ranges 0 -300amp without external shunt size 96 x 96mm square type class 1.5/2.5, confirm to is: 1248 make ae /indotech and yokins, suitable for battery charger of ac coaches.
Dc ampere meter moving coil type ranges 0 -300amp without external shunt size 96 x 96mm square type class 1.5/2.5, confirm to is: 1248 make ae /indotech and yokins, suitable for battery charger of ac coaches.
Read moreContactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Read morePower contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.
Power contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.
Read moreWorking and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4
Working and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4
Read moreClear silica gel breather 8 kg,200a tpn 415v rewireable fuse main switch,400a tpn 415v rewireable fuse main switch,highly insulated discharge rod with grip,closing coil solenoid for 170 kv gcb rating 220v to 250 v dc,tripping coil shunt trip for 170 kv gcb rating 220v to 250 v dc,tinned copper braided jumper size 44 mm w into 15 mm t into 510 mm l,tinned copper braided jumper size 55 mm w into 7 mm t into 490 mm l,copper laminated jumper size 48 mm w into 14point6 mm t into 335 mm l,voltage protection relay
Clear silica gel breather 8 kg,200a tpn 415v rewireable fuse main switch,400a tpn 415v rewireable fuse main switch,highly insulated discharge rod with grip,closing coil solenoid for 170 kv gcb rating 220v to 250 v dc,tripping coil shunt trip for 170 kv gcb rating 220v to 250 v dc,tinned copper braided jumper size 44 mm w into 15 mm t into 510 mm l,tinned copper braided jumper size 55 mm w into 7 mm t into 490 mm l,copper laminated jumper size 48 mm w into 14point6 mm t into 335 mm l,voltage protection relay
Read moreAoh (18 month) replacement kit (aal part no:4300007100/30 or latest) for single bottle vcb of m/s aal type: vcba 25.10 tr. as per rdso smino: elrs/sim/0236 rev-1, dated 31.12.2012 and amendment no.1 by rdso l no:el/3.2.61, dated 14.02.2013, suitable for motor coach of memu. one set comprising of 05 items as (annexure-a1).
Aoh (18 month) replacement kit (aal part no:4300007100/30 or latest) for single bottle vcb of m/s aal type: vcba 25.10 tr. as per rdso smino: elrs/sim/0236 rev-1, dated 31.12.2012 and amendment no.1 by rdso l no:el/3.2.61, dated 14.02.2013, suitable for motor coach of memu. one set comprising of 05 items as (annexure-a1).
Read moreRasin cast spout assy,spout filling with connector r y b,front insulated connector r phase,front insulated connector y phase phase,front insulated connector b phase,rear insulated connector r phase,rear insulated connector y phase,rear insulated connector b phase,instrument control box,vertical isolating trolley,earth leakage relay with cbct,power converter 110 v ac to 110 v dc,tripping coil,mechanism for tripping coil,master trip relay,epoxy resin cast potential transformer 11 kv 110v,digital protection relay,epoxy resin cast current transformer,side cable box
Rasin cast spout assy,spout filling with connector r y b,front insulated connector r phase,front insulated connector y phase phase,front insulated connector b phase,rear insulated connector r phase,rear insulated connector y phase,rear insulated connector b phase,instrument control box,vertical isolating trolley,earth leakage relay with cbct,power converter 110 v ac to 110 v dc,tripping coil,mechanism for tripping coil,master trip relay,epoxy resin cast potential transformer 11 kv 110v,digital protection relay,epoxy resin cast current transformer,side cable box
Read moreof your Industry type