Tender Details
Particulars | Details |
---|---|
Title |
Daboda Khurd, Dnit For Repair Of 1 No. Existing Brick Masonry Storage And Sedimentation Tank Of 100 X 100 X 6ft Or 30.48 M X 30.48 M X 1.83 M, Existing Pump Chamber Of Size 13ftx28ft, Repair Of 2 Nos. Filter Beds Of Size 40ft X2ft
|
Description |
Daboda Khurd, Dnit For Repair Of 1 No. Existing Brick Masonry Storage And Sedimentation Tank Of 100 X 100 X 6ft Or 30.48 M X 30.48 M X 1.83 M, Existing Pump Chamber Of Size 13ftx28ft, Repair Of 2 Nos. Filter Beds Of Size 40ft X2ft
|
Organisation | Haryana Government | State Govt. and UT |
Tender Id | 2024_HRY_399143_1 |
Reference Number |
2024B03F1E6F 7644 4AB6 9AB0 4E3B4433E8CD593PUH |
Tender Fee | 16000 |
EMD | 2.83 Lakh |
Tender Value | |
Place | DABODA KHURD |
Link | https://etenders.hry.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=475498 |
Start Date | August 12, 2024 14:30 |
End Date |
22/08/2024 ( Expired 291 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Repair or maintenance of filter bed, cleaning of sludge, cleaning of overhead and sedimentation tank, repair or replacement of sluice chamber, pipe lines, floculator system at pump house no 01 at hq eac (u) (af) under ge (i) (af) shillong
Repair or maintenance of filter bed, cleaning of sludge, cleaning of overhead and sedimentation tank, repair or replacement of sluice chamber, pipe lines, floculator system at pump house no 01 at hq eac (u) (af) under ge (i) (af) shillong
Read moreDnit for washing of all filter media layers for smooth running of filter beds for kanonda 2 nos. of 11.50 x 17.00 m each and all other works contingent thereto
Dnit for washing of all filter media layers for smooth running of filter beds for kanonda 2&#x0d nos. of 11.50 x 17.00 m each and all other works contingent thereto
Read moreKablana dnit for const. of 1 no. rcc s.s tank of size 151ftx151ftx6ft or 46.02 x 46.02 x 1.83 mtr, strengthening,repair of b/wall, repair of exist. p.c. of 3.96 x 8.53 m, const. of cc path, earth filling in both exist. s.s tanks and vacate (recall)
Kablana dnit for const. of 1 no. rcc s.s tank of size 151ftx151ftx6ft or 46.02 x 46.02 x 1.83 mtr, strengthening,repair of b/wall, repair of exist. p.c. of 3.96 x 8.53 m, const. of cc path, earth filling in both exist. s.s tanks and vacate (recall)
Read moreDaboda khurd, dnit for repair of 1 no. existing brick masonry storage and sedimentation tank of 100 x 100 x 6ft or 30.48 m x 30.48 m x 1.83m, existing pump chamber of size 13ftx28ft, repair of 2 nos. filter beds of size 40ft x2ft (recall)
Daboda khurd, dnit for repair of 1 no. existing brick masonry storage and sedimentation tank of 100 x 100 x 6ft or 30.48 m x 30.48 m x 1.83m, existing pump chamber of size 13ftx28ft, repair of 2 nos. filter beds of size 40ft x2ft (recall)
Read moreKablana dnit for const. of 1 no. rcc s.s tank of size 151ftx151ftx6ft or 46.02 x 46.02 x 1.83 mtr, strengthening,repair of b/wall, repair of exist. p.c. of 3.96 x 8.53 m, const. of cc path, earth filling in both exist. s.s tanks and vacate (recall)
Kablana dnit for const. of 1 no. rcc s.s tank of size 151ftx151ftx6ft or 46.02 x 46.02 x 1.83 mtr, strengthening,repair of b/wall, repair of exist. p.c. of 3.96 x 8.53 m, const. of cc path, earth filling in both exist. s.s tanks and vacate (recall)
Read moreKablana dnit for const. of 1 no. rcc s.s tank of size 151ftx151ftx6ft or 46.02 x 46.02 x 1.83 mtr, strengthening,repair of b/wall, repair of exist. p.c. of 3.96 x 8.53 m, const. of cc path, earth filling in both exist. s.s tanks and vacate areaofww
Kablana dnit for const. of 1 no. rcc s.s tank of size 151ftx151ftx6ft or 46.02 x 46.02 x 1.83 mtr, strengthening,repair of b/wall, repair of exist. p.c. of 3.96 x 8.53 m, const. of cc path, earth filling in both exist. s.s tanks and vacate areaofww
Read moreHassanpur parnala, dnit, for repair of existing 1 no. storage and sedimentation tank of size 33.53 x 33.53 x 1.83 m, 2 nos. high level tanks of size of size 10.67 x 7.32 x 1.83 m, 3 no. rcc filter beds of size 12.19 x 8.23 m, 2 no. rcc cwt (recall)
Hassanpur parnala, dnit, for repair of existing 1 no. storage and sedimentation tank of size 33.53 x 33.53 x 1.83 m, 2 nos. high level tanks of size of size 10.67 x 7.32 x 1.83 m, 3 no. rcc filter beds of size 12.19 x 8.23 m, 2 no. rcc cwt (recall)
Read moreMattan, dnit for construction of 2 nos. additional rcc clear water tanks of size 6.10 x 4.27 m, construction of 2 nos. additional r.cc filter beds of size 6.40 x 4.27 m, repair of existing 2 nos. storage sedimentation tanks of size 51.8x82x1.83 m
Mattan, dnit for construction of 2 nos. additional rcc clear water tanks of size 6.10 x 4.27 m, construction of 2 nos. additional r.cc filter beds of size 6.40 x 4.27 m, repair of existing 2 nos. storage sedimentation tanks of size 51.8x82x1.83 m
Read moreDaboda khurd, dnit for repair of 1 no. existing brick masonry storage and sedimentation tank of 100 x 100 x 6ft or 30.48 m x 30.48 m x 1.83m, existing pump chamber of size 13ftx28ft, repair of 2 nos. filter beds of size 40ft x2ft
Daboda khurd, dnit for repair of 1 no. existing brick masonry storage and sedimentation tank of 100 x 100 x 6ft or 30.48 m x 30.48 m x 1.83m, existing pump chamber of size 13ftx28ft, repair of 2 nos. filter beds of size 40ft x2ft
Read moreHassanpur parnala, dnit, for repair of existing 1 no. storage and sedimentation tank of size 33.53 x 33.53 x 1.83 m, 2 nos. high level tanks of size of size 10.67 x 7.32 x 1.83 m, 3 no. rcc filter beds of size 12.19 x 8.23 m, 2 no. rcc clear water
Hassanpur parnala, dnit, for repair of existing 1 no. storage and sedimentation tank of size 33.53 x 33.53 x 1.83 m, 2 nos. high level tanks of size of size 10.67 x 7.32 x 1.83 m, 3 no. rcc filter beds of size 12.19 x 8.23 m, 2 no. rcc clear water
Read moreof your Industry type