Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Thoracic Aneursym Endovascular Graft Compatible With Stennotic Or Low Profile Femoral Or Iliac With
|
| Description |
|
| Organisation | Department of Military Affairs | Ministry of Defence |
| Tender Id | GEM/2024/B/5177412 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | July 29, 2024 18:45 |
| End Date |
Expired
19/08/2024
Expired 790 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
Abdominal aortic aneurysm endo prosthesis contra lateral leg,abdominal aortic aneurysm endo prosthesis,tapered thoracic aortic aneurysm endovascular graft size 22,tapered thoracic aortic aneurysm endovascular graft size 22,aaa unilliac graft size 23 to 28mm prox diameter x 12 to14 mm,lliac extender graft size of distal dia of 12 to 24mm 55 to 125mm
Abdominal aortic aneurysm endo prosthesis contra lateral leg,abdominal aortic aneurysm endo prosthesis,tapered thoracic aortic aneurysm endovascular graft size 22,tapered thoracic aortic aneurysm endovascular graft size 22,aaa unilliac graft size 23 to 28mm prox diameter x 12 to14 mm,lliac extender graft size of distal dia of 12 to 24mm 55 to 125mm
Read moreOrtic stent graft :- shou [srphc82281040-aortic stent graft :- should enable endovascular treatment of arch of aorta and descending thoracic aorta aneurysms and dissections. the stent graft should come in various lengths and diameters. it should consist of (1) a self expanding, tubular endoprosthesis composed of a polyester graft fabric and a spring scaffold made from nitinol wire. (2) radiopaque markers are to be sewn to the fabric to radiographically visualize the edge of the graft material
Ortic stent graft :- shou [srphc82281040-aortic stent graft :- should enable endovascular treatment of arch of aorta and descending thoracic aorta aneurysms and dissections. the stent graft should come in various lengths and diameters. it should consist of (1) a self expanding, tubular endoprosthesis composed of a polyester graft fabric and a spring scaffold made from nitinol wire. (2) radiopaque markers are to be sewn to the fabric to radiographically visualize the edge of the graft material
Read moreDistal femoral replacement prosthesis set: consisting of femoral component, tibial component, articul,proximal tibial replacement prosthesis consisting of: femoral component, tibial component with o,proximal femoral replacement prosthesis set: consisting of proximal femoral component, compatible met
Distal femoral replacement prosthesis set: consisting of femoral component, tibial component, articul,proximal tibial replacement prosthesis consisting of: femoral component, tibial component with o,proximal femoral replacement prosthesis set: consisting of proximal femoral component, compatible met
Read moreLow profile titanium cancellous screws of diameter 4.0 mm
Low profile titanium cancellous screws of diameter 4.0 mm
Read moreUncemented modular bipolar hemiarthroplasty implant mri compatible (consisting of shell liner, internal head & uncemented femoral stem) item code no.: s61311 ai 26-27
Uncemented modular bipolar hemiarthroplasty implant mri compatible (consisting of shell liner, internal head & uncemented femoral stem) item code no.: s61311 ai 26-27
Read moreGan driver evaluation module compatible with tps7h6003,ganfet evaluation module compatible with epc2304,ganfet 200v, 130a or better,ganfet low side and high side driver for 650v bridge operation,ganfet with integrated driver
Gan driver evaluation module compatible with tps7h6003,ganfet evaluation module compatible with epc2304,ganfet 200v, 130a or better,ganfet low side and high side driver for 650v bridge operation,ganfet with integrated driver
Read moreSuture anchor should be made of peek material 4.75mm./ suture anchor should be made of peek material. 5.5 mm. / low profile titanium cancellous screws of diameter 4.0 mm and 6.5mm.
Suture anchor should be made of peek material 4.75mm./ suture anchor should be made of peek material. 5.5 mm. / low profile titanium cancellous screws of diameter 4.0 mm and 6.5mm.
Read moreUltraporous acetabular shell with compatible crosslinked polyethylene liner with two screw (size 44/,revision acetabular cup with ischial flange/peripheral rim screws (to include 08 screws) /(size 56/58,posterior stabilised knee consisting of: cobalt chromium femoral component matching highly crosslin
Ultraporous acetabular shell with compatible crosslinked polyethylene liner with two screw (size 44/,revision acetabular cup with ischial flange/peripheral rim screws (to include 08 screws) /(size 56/58,posterior stabilised knee consisting of: cobalt chromium femoral component matching highly crosslin
Read moreFemoral introducer sheath with puncture needle for adults,radial introducer sheath with puncture needle for adults,special slender introducer sheath,ptca y connector kit,manifold,leur lock syringe,thoracic aortic stent graft,abdominal aortic stent graft,head hunter cathetar,simmons or sidewinder cathetar,non ionic mono meric contrast media, iohexol,non ionic diameric contrast media, iodixanol,angiography cine recordable disk,angiography drape set,ptca balloon 1, semi compliant,ptca balloon 2, semi compliant,ptca balloon 3, semi compliant,ptca balloon 4, semi compliant,ptca balloon 5, semi compliant,ptca balloon 6, semi compliant,ptca balloon 1, non compliant,ptca balloon 2, non compliant,ptca balloon 3, non compliant,ptca balloon 4, non compliant,ptca balloon 5, non compliant,paclitaxel drug eluting ptca balloon,sirolimus drug eluting ptca balloon,drug eluting ptca balloon,coronary stents 1,coronary stents 2,coronary stents 3,coronary stents 4,coronary stents 5,coronary stents 6,coronary stents 7,coronary ste
Femoral introducer sheath with puncture needle for adults,radial introducer sheath with puncture needle for adults,special slender introducer sheath,ptca y connector kit,manifold,leur lock syringe,thoracic aortic stent graft,abdominal aortic stent graft,head hunter cathetar,simmons or sidewinder cathetar,non ionic mono meric contrast media, iohexol,non ionic diameric contrast media, iodixanol,angiography cine recordable disk,angiography drape set,ptca balloon 1, semi compliant,ptca balloon 2, semi compliant,ptca balloon 3, semi compliant,ptca balloon 4, semi compliant,ptca balloon 5, semi compliant,ptca balloon 6, semi compliant,ptca balloon 1, non compliant,ptca balloon 2, non compliant,ptca balloon 3, non compliant,ptca balloon 4, non compliant,ptca balloon 5, non compliant,paclitaxel drug eluting ptca balloon,sirolimus drug eluting ptca balloon,drug eluting ptca balloon,coronary stents 1,coronary stents 2,coronary stents 3,coronary stents 4,coronary stents 5,coronary stents 6,coronary stents 7,coronary ste
Read moreTissue valve (bovine) aortic of different sizes (aortic bovine tissue valve with latest anti calcification treatment with adequate size soft and pliable sewing cuff. the valve should have low profile with narrow commisure post giving more space for knot tying with simple one cut release of valve holder). eyery sizes of the valve should be available with the suppling firm and all sizes of the valve to be provided before procedure.[item code no.:s62286 ,ai/2026-27 ]
Tissue valve (bovine) aortic of different sizes (aortic bovine tissue valve with latest anti calcification treatment with adequate size soft and pliable sewing cuff. the valve should have low profile with narrow commisure post giving more space for knot tying with simple one cut release of valve holder). eyery sizes of the valve should be available with the suppling firm and all sizes of the valve to be provided before procedure.[item code no.:s62286 ,ai/2026-27 ]
Read moreof your Industry type