Tender Details
Particulars | Details |
---|---|
Title |
Supply , Installation And Commissioning Of Restricted Neutral Grounding Monitoring System Of 01 Nos. 3.3 Kv 550 V Transformer At Millennium Incline 31 L 28 D Of Shankarpur Colliery Under Bankola Area (Retender).
|
Description |
Supply , Installation And Commissioning Of Restricted Neutral Grounding Monitoring System Of 01 Nos. 3.3 Kv 550 V Transformer At Millennium Incline 31 L 28 D Of Shankarpur Colliery Under Bankola Area (Retender).
|
Organisation | Eastern Coalfields Limited | Public Sector Undertakings |
Tender Id | 2025_ECL_329761_1 |
Reference Number |
ECL/GM/BA/E TENDER/24-25/ENM/303(02) Dt 20.02.2025 |
Tender Fee | 0 |
EMD | 1900 |
Tender Value | |
Place | Shankarpur Colliery |
Link | https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=341798 |
Start Date | February 20, 2025 23:30 |
End Date |
03/03/2025 ( Expired 93 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Civil works at gdk 1 incline fan house outdoor sub-station for the addition of 1no.1600kva, 33kv/ 3.3kv power transformer for providing power supply arrangements for the proposed rapid gravity filter bed in rg-i area, gdk. (invited under earmarked work for sc community contractors only)
Civil works at gdk 1 incline fan house outdoor sub-station for the addition of 1no.1600kva, 33kv/ 3.3kv power transformer for providing power supply arrangements for the proposed rapid gravity filter bed in rg-i area, gdk. (invited under earmarked work for sc community contractors only)
Read moreOverhauling, changing of gaskets, replacement of brass studs, heating of 1000kva, 11kv/3.3kv-550v transformer of phularitand, amp colliery under barora area.
Overhauling, changing of gaskets, replacement of 
 brass studs, heating of 1000kva, 11kv/3.3kv-550v 
 transformer of phularitand, amp colliery under 
 barora area.
Read moreRepairing of 03 nos. 3.3kv and 550v rated ocbs installation at mine-a under bhurkunda colliery.
Repairing of 03 nos. 3.3kv and 550v rated ocbs installation at mine-a under bhurkunda colliery.
Read moreProviding, installation, commissioning, testing of 4 nos. neutral grounding resistor (ngr), 3300v, 10 a and 3 nos. ngr, 6600v, 10 a ratings with fail safe monitoring system at 33kv main substation and old substation of dipka expansion project.
Providing, installation, commissioning, testing of 4 nos. neutral grounding resistor (ngr), 3300v, 10 a and 3 nos. ngr, 6600v, 10 a ratings with fail safe monitoring system at 33kv main substation and old substation of dipka expansion project.
Read moreSurvey, design, fabrication, supply, installation, testing, commissioning with rms of 01 no. 05hp.dc solar water pumping system, 06 nos. of solar based led high mast 9 mtr. with rms, 08 nos. of ssls 8 mtr. at various locations in dist. amravati
Survey, design, fabrication, supply, installation, testing, commissioning with rms of 01 no. 05hp.dc solar water pumping system, 06 nos. of solar based led high mast 9 mtr. with rms, 08 nos. of ssls 8 mtr. at various locations in dist. amravati
Read moreRepairing and overhauling of restricted neutral grounding system of 1.5 mva 11kv/3.3kv transformer at ena ocb substation at kusunda area.
Repairing and overhauling of restricted neutral grounding system of 1.5 mva 11kv/3.3kv transformer at ena ocb substation at kusunda area.
Read moreRenovation of power supply ohl and laying, testing and commissioning of underground cabling system from 3.3kv/415v transformer to individual quarter at dera dlb colony and sharma chakk colony of lingaraj area
Renovation of power supply ohl and laying, testing and commissioning of underground cabling system from 3.3kv/415v transformer to individual quarter at dera dlb colony and sharma chakk colony of lingaraj area
Read moreDehydration, filtration and commissioning of 1 mva 11kv/3.3kv power transformer, 100kva 3.3kv/440v lightening transformer, 25kva 550v/220v lightening transformer and 300kva 3.3 kv/440v lightening transformer at south samla unit of msam colliery under
Dehydration, filtration and commissioning of 1 mva 11kv/3.3kv power transformer, 100kva 3.3kv/440v lightening transformer, 25kva 550v/220v lightening transformer and 300kva 3.3 kv/440v lightening transformer at south samla unit of msam colliery under
Read moreSupply, fitting and commissioning of electrical protective system in 550 volt acb switches at underground workings to comply dgms violation and maintaining electrical safety in pit no b and 2 under pandaveswar colliery, pandaveswar area
Supply, fitting and commissioning of electrical protective system in 550 volt acb switches at underground workings to comply dgms violation and maintaining electrical safety in pit no b and 2 under pandaveswar colliery, pandaveswar area
Read moreOperation and maintenance of electrical, air conditioner, dg set, transformer and water supply system installed at technical and non technical area at cmsds baruipur (fy 2025-26), cce(r and d)e/enq-01/em/kol/2025-26
Operation and maintenance of electrical, air conditioner, dg set, transformer and water supply system installed at technical and non technical area at cmsds baruipur (fy 2025-26)
Read moreof your Industry type