Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Providing And Fixing Pressure Sand Filtration Plant, Pumping Machinery, Distribution And Repair Of Other Structures At Existing Water Supply Scheme Managat Ker Block And Distt. Sri Muktsar Sahib. (Under Aca/Pidb)
|
| Description |
Repair Of Storage And Sedimentation Tank Of Size 59.98 X44.58 X1.68 M, Repair Of Cwt 9.75 M Dia, Repair Of Pump Chamber 6.10 X 4.88 M, New Pumping Machinery, Repair Of Existing Ohsr 100 Kl, Provision Of Boundry Wall, Footpath And Sign Board, Providing
|
| Organisation | Government of Punjab |
| Tender Id | 2024_WSS_115377_1 |
|
Reference Number |
Manget Ker ACA/PIDB |
| Tender Fee | 1000 |
| EMD | 80204 |
| Tender Value | |
| Place | WSS Div. No.1 Sri Muktsar Sahib |
| Link |
View Original Tender Notice
https://eproc.punjab.gov.in |
| Start Date | January 09, 2024 23:30 |
| End Date |
Expired
24/01/2024
Expired 882 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Water supply scheme jahangirpur, block ludhiana-ii, district. ludhiana. (under jjm/aca)
Providing and installing new deep tube well size 200 mm i/d up to 150mtr. depth bgl with reverse rotary rig, pumping main, pumping machinery, chlorinator and repair of existing structures
Read moreProviding and fixing pressure sand filtration plant (20 cum hr. 2 nos.), distribution and repair of other structures at existing water supply scheme lakhewali block and distt. sri muktsar sahib. (under aca pidb)
Repair of storage and sedimentation tank of size 107.10x34.60x1.90 m, repair of 2 nos cwt (7.64 and 10.0 m dia), repair of pump chamber 6.10 x 4.88 m, repair of existing ohsr 200 kl, provision of boundry wall
Read moreProviding and fixing pressure sand filtration plant (20 cum hr. 2 nos.), distribution and repair of other structures at existing water supply scheme lakhewali block and distt. sri muktsar sahib. (under aca pidb)
Repair of storage and sedimentation tank of size 107.10x34.60x1.90 m, repair of 2 nos cwt (7.64 and 10.0 m dia), repair of pump chamber 6.10 x 4.88 m, repair of existing ohsr 200 kl, provision of boundry wall, footpath and sign board
Read moreProviding and fixing pressure sand filtration plant (20 cum hr. 2 nos.), distribution and repair of other structures at existing water supply scheme lakhewali block and distt. sri muktsar sahib. (under aca pidb)
Repair of storage and sedimentation tank of size 107.10x34.60x1.90 m, repair of 2 nos cwt (7.64 and 10.0 m dia), repair of pump chamber 6.10 x 4.88 m, repair of existing ohsr 200 kl, provision of boundry wall, footpath and sign board
Read moreProviding and fixing pressure sand filtration plant (20 cum hr. 2 nos.), distribution and repair of other structures at existing water supply scheme lakhewali block and distt. sri muktsar sahib. (under aca pidb)
Repair of storage and sedimentation tank of size 107.10x34.60x1.90 m, repair of 2 nos cwt (7.64 and 10.0 m dia), repair of pump chamber 6.10 x 4.88 m, repair of existing ohsr 200 kl, provision of boundry wall, footpath and sign board,
Read moreProviding and fixing pressure sand filtration plant (20 cum hr 2 nos.), distribution and repair of other structures at existing water supply scheme lakhewali block and distt. sri muktsar sahib. (under aca pidb)
Repair of storage and sedimentation tank of size 107.10x34.60x1.90 m, repair of 2 nos cwt (7.64 and 10.0 m dia), repair of pump chamber 6.10 x 4.88 m, repair of existing ohsr 200 kl, provision of boundry wall, footpath
Read moreProviding and fixing pressure sand filtration plant and repair of other structures at existing water supply scheme gulabewala block and distt. sri muktsar sahib. (under aca project)
Providing and laying rcc 250 mm i/d piped inlet channel, de silting of existing piped inlet channel, provision of floating arm for old storage and sedimentation tank of size 34.16x50.31x1.96 m, repair of clear water tank 7.50 m dia, repair of pump ch
Read moreProviding and fixing of 450 mm and 560 mm rcc main hole cover and frame in various streets of across the railway area at sri muktsar sahib distt sri muktsar sahib
Providing and fixing of 450 mm and 560 mm rcc main hole cover and frame in various streets of across the railway area at sri muktsar sahib distt sri muktsar sahib
Read moreReplacement of damaged sewer pipe line and drinking water pipe line main water supply pipe line of chak bir sarkar water supply at bathinda chowk to civil hospital sri muktsar sahib distt sri muktsar sahib
Replacement of damaged sewer pipe line and drinking water pipe line main water supply pipe line of chak bir sarkar water supply at bathinda chowk to civil hospital sri muktsar sahib distt sri muktsar sahib
Read moreBohal- estimate for repair...
Construction of 1 no. cwt, repair/renovation of existing structures, providing and erection of pumping machinery and distribution system.
Read moreof your Industry type