Tender Details

Particulars Details
Title
Laying Of Lt Line On 8 Mtr. St Poles Using Acsr Weasel Conductor For Providing Ut Wide Power To Cctv Survillance System On Turnkey Basis
Description
Laying Of Lt Line On 8 Mtr. St Poles Using Acsr Weasel Conductor For Providing Ut Wide Power To Cctv Survillance System On Turnkey Basis With In The Jurisdiction Of Electric Division Vijaypur Jpdcl Jammu
Organisation Government of Jammu and Kashmir
Tender Id 2023_PDD_226924_1
Reference
Number
EDV 30 of 2023-2024 Dated 19.08.2023
Tender Fee 500
EMD 12500
Tender Value -
Place Office of Executive Engineer Electric Div vijaypur
Link
View Original Tender Notice

https://jktenders.gov.in

Start Date August 20, 2023 15:30
End Date
Expired 02/09/2023

Expired 1138 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Acsr weasel conductor

As technical specification

Read more
Repairs / replacement of lt poles, acsr conductor, mcb and cables, street lights, security lights and misc e/m works at chh sambhajinagar mil station under ge (s) ahilyanagar

Repairs / replacement of lt poles, acsr conductor, mcb and cables, street lights, security lights and misc e/m works at chh sambhajinagar mil station under ge (s) ahilyanagar

Read more
Construction of 11kv covered conductor line using psc poles from mylakonam to manali and installation of 100 kva transformer at kaduvakonam under electrical section, kattakada of electrical division, kattakada under electrical circle, kattakada

Construction of 11kv covered conductor line using psc poles from mylakonam to manali and installation of 100 kva transformer at kaduvakonam under electrical section, kattakada of electrical division, kattakada under electrical circle, kattakada

Read more
Supply, erection, testing and commissioning of i) conversion of 132kv 2-ph double circuit line to 3-ph double circuit line (15km) from 220/132kv ss budidampadu to 132/25kv rtss-dornakal by stringing 3rd acsr panther conductor (ii) modification of 2nos.132kv bays from 2-ph to 3-ph at 220/132kv ss budidampadu and (iii) erection of 2nos 132kv metering bays at newly proposed 132/25kv rtss-dornakal in khammam district on turnkey basis

Supply, erection, testing and commissioning of i) conversion of 132kv 2-ph double circuit line to 3-ph double circuit line (15km) from 220/132kv ss budidampadu to 132/25kv rtss-dornakal by stringing 3rd acsr panther conductor (ii) modification of 2nos.132kv bays from 2-ph to 3-ph at 220/132kv ss budidampadu and (iii) erection of 2nos 132kv metering bays at newly proposed 132/25kv rtss-dornakal in khammam district on turnkey basis

Read more
Establishment of 2x20mva, 110/11kv sub-station at kannalli along with construction of 110kv lilo line using lynx conductor from existing 110kv kembhavi-hunasagi sc line to the proposed 110/11kv kannalli sub-station for a distance of 10.685km in hunasagi taluk, yadgir district on partial turnkey basis including supply of all matching materials/equipments (excluding supply 11kv switchgear) and erection (including dismantling and civil works) of all materials/ equipment, testing and commissioning.

Establishment of 2x20mva, 110/11kv sub-station at kannalli along with construction of 110kv lilo line using lynx conductor from existing 110kv kembhavi-hunasagi sc line to the proposed 110/11kv kannalli sub-station for a distance of 10.685km in hunasagi taluk, yadgir district on partial turnkey basis including supply of all matching materials/equipments (excluding supply 11kv switchgear) and erection (including dismantling and civil works) of all materials/ equipment, testing and commissioning.

Read more
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable

Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable

Read more
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable

Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable

Read more
Laying of lt line on 8 mtr. pcc/ st poles using acsr weasel conductor (single, two and three phase)

Laying of lt line on 8 mtr. pcc/ st poles using acsr weasel conductor (single, two and three phase) on turnkey basis with in the jurisdiction of electric division vijaypur jpdcl jammu

Read more
Acsr weasel conductor

As per tender specification

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise