Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
About Tender
🔧 Bharat Coking Coal Limited (Bccl) Rfp For 3.3 Kv Main Switch Repair And Maintenance 🛠️ Bharat Coking Coal Limited (Bccl), A Public Sector Undertaking, Is Issuing A Request For Proposal (Rfp) For The Repairing And Maintenance Of A 400 A 3.3 Kv, Ocb Switch, Model Sl. No. Bph/01, Located At The Vtc Main Switch Installed At The Bhowra Power House Substation. 🏭 📅 Proposal Submission Deadline: June 07, 2024, 5:00 Pm Interested Vendors Must Submit An Earnest Money Deposit (Emd) Of Inr 769 And Provide Detailed Technical And Financial Proposals To Address The Repairing And Maintenance Requirements Of The Specified Equipment. Keywords: Repairing And Maintenance, 3.3 Kv Main Switch, Ocb, Bharat Coking Coal Limited, Public Sector Undertaking, Rfp, Electrical Equipment, Bhowra Power House Substation, Emd| Particulars | Details |
|---|---|
| Title |
Repairing And Maintenanceof 400 A 3.3 Kv,Ocb English Electrical Make Sl. No. Bph/01 Of Vt Cmain Switch Installed At Bhowra Power Housesubstation..
|
| Description |
Repairing And Maintenanceof 400 A 3.3 Kv,Ocb English Electrical Make Sl. No. Bph/01 Of Vt Cmain Switch Installed At Bhowra Power Housesubstation..
|
| Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
| Tender Id | 2024_BCCL_308866_1 |
|
Reference Number |
BCCL/EJA/ENM/E Tender/2024-25/45 |
| Tender Fee | 0 |
| EMD | 769 |
| Tender Value | - |
| Place | E. J. Area, Bhowra |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=320047 |
| Start Date | May 24, 2024 22:30 |
| End Date |
Expired
07/06/2024
Expired 862 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
For repairing of incomer 400a,6.6kv, ocb switch sl.no. bsp/switch/06 make ferguson at ekra substation basdeopur colliery under sijua area
For repairing of incomer 400a,6.6kv, ocb switch sl.no. bsp/switch/06 make ferguson at ekra substation basdeopur colliery under sijua area
Read moreRepairing, rewinding and installation of k-sambhav make, 11kv-3.3kv, 2mva transformer installed at chp substation at shyamsundarpur colliery under bankola area.
Repairing, rewinding and installation of k-sambhav make, 11kv-3.3kv, 2mva transformer installed at chp substation at shyamsundarpur colliery under bankola area.
Read moreComplete repairing and re-winding of (a) 02-nos. 500 kva, 3.3kv/440v (b) 01-no. 250kva, 3.3kv/440v and (c) 01-no. 160 kva, 11 kv/440 distribution transformers installed at different locations of kathara colliery under kathara area.
Complete repairing and re-winding of (a) 02-nos. 500 kva, 3.3kv/440v (b) 01-no. 250kva, 3.3kv/440v and (c) 01-no. 160 kva, 11 kv/440 distribution transformers installed at different locations of kathara colliery under kathara area.
Read moreHand drill machine 600w 230v 1 point 5 13mm 2800rpm,tester tong 0 to 1000a 660v,3.3kv 400amps fwd off rev isolator part no htsv0003,master trip relay 110v dc cspc86 part no 1907739,puller bearing hyd 10ton,contactor main 550v 300 by 400a,tester hv detector 0 to 11kv for flp switch
Hand drill machine 600w 230v 1 point 5 13mm 2800rpm,tester tong 0 to 1000a 660v,3.3kv 400amps fwd off rev isolator part no htsv0003,master trip relay 110v dc cspc86 part no 1907739,puller bearing hyd 10ton,contactor main 550v 300 by 400a,tester hv detector 0 to 11kv for flp switch
Read moreRepairing and rewinding of 02 nos. of distribution transformers, 250kva, 11kv/440v and 250kva, 3.3kv/440v installed at cisf colony and gurudwara chowk under gm unit nk area.
Repairing and rewinding of 02 nos. of distribution transformers, 250kva, 11kv/440v and 250kva, 3.3kv/440v installed at cisf colony and gurudwara chowk under gm unit nk area.
Read moreAnnual maintenance contract (non camc) of 8 no. ups of different capacity & 2 no. ats switch installed in technical area/s at dd news delhi.
Annual maintenance contract (non camc) of 8 no. ups of different capacity & 2 no. ats switch installed in technical area/s at dd news delhi.
Read moreRepair/maint of ht vcb, transformer, ht cable, ht god/switch other allied connected works installed at nimu and nurla mil stn under age(i) nimu.
Repair/maint of ht vcb, transformer, ht cable, ht god/switch other allied connected works installed at nimu and nurla mil stn under age(i) nimu.
Read moreSpares suitable for siemens make 420 kv,2000amps,tp 415v motor operated centre break isolator with single earth switch type 400 kv hcb installed at 400 kv switchyard
Spares suitable for siemens make 420 kv,2000amps,tp 415v motor operated centre break isolator with single earth switch type 400 kv hcb installed at 400 kv switchyard
Read moreL and t hrc fuse 160a hn160 cat no sf 94131,fuse switch type fb 250 l and t,switches of 125a cat 415v sk95001,sdf type fn 630 tpn sk95521 l and t,switch disconnector fuse unit fn32,switch fuse unit 400a 415v tpn sh steel,mccb rating 400a 3pole 50ka,mccb dn0 100m 100a tm release l and t make,mccb mtx 2 0 dn2 250n 250a l and t make,add on block for ml10 12 contactor l and t,l and t make 110a ac3 ml6 contactor,power contactor 240v ac ty mnx400,power contactor 4 p 325a ty mcx 41,32 50 a bimetallic over load relay,mccb 125a,3 2 5 a over load relay,overload relay bimetalic
L and t hrc fuse 160a hn160 cat no sf 94131,fuse switch type fb 250 l and t,switches of 125a cat 415v sk95001,sdf type fn 630 tpn sk95521 l and t,switch disconnector fuse unit fn32,switch fuse unit 400a 415v tpn sh steel,mccb rating 400a 3pole 50ka,mccb dn0 100m 100a tm release l and t make,mccb mtx 2 0 dn2 250n 250a l and t make,add on block for ml10 12 contactor l and t,l and t make 110a ac3 ml6 contactor,power contactor 240v ac ty mnx400,power contactor 4 p 325a ty mcx 41,32 50 a bimetallic over load relay,mccb 125a,3 2 5 a over load relay,overload relay bimetalic
Read moreAmpere meter 4inch ratio 200 100 5 5a part no spl406,volt meter 3.3kv 100v part no spl106,ammeter selector switch part no srp136ma,voltmeter selector switch part no srp135vs,earth leakage relay 0.34 to 1.8a aux supply 110v cbct part no ekjrc172,wiring kit part no ek805888,epoxy resin cast ct double core 15va ratio 200 100 5 5a part no ct5300,epoxy resin cast potential transformer 3.3 kv 110v 3phase part no et08002,power pack unit 110v dc part no ek801025
Ampere meter 4inch ratio 200 100 5 5a part no spl406,volt meter 3.3kv 100v part no spl106,ammeter selector switch part no srp136ma,voltmeter selector switch part no srp135vs,earth leakage relay 0.34 to 1.8a aux supply 110v cbct part no ekjrc172,wiring kit part no ek805888,epoxy resin cast ct double core 15va ratio 200 100 5 5a part no ct5300,epoxy resin cast potential transformer 3.3 kv 110v 3phase part no et08002,power pack unit 110v dc part no ek801025