Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Erection Of 110 Kv Dc Line On Dc Tower (2.439 Km) With Panther Conductor By Making Lilo At 110 Kv Pasumalai Anuppankulam Feeder For The Proposed Mykudi 110 Kv Ss In Madurai Reach 2
|
| Description |
Erection Of 110 Kv Dc Line On Dc Tower (2.439 Km) With Panther Conductor By Making Lilo At 110 Kv Pasumalai Anuppankulam Feeder For The Proposed Mykudi 110 Kv Ss In Madurai Reach 2
|
| Organisation | TNEB Limited | State Govt. and UT |
| Tender Id | 2025_EB_622646_1 |
|
Reference Number |
CE/TP-II/TRY/C-70/25-26 |
| Tender Fee | 0 |
| EMD | 2.09 Lakh |
| Tender Value | - |
| Place | MYKUDI |
| Link |
View Original Tender Notice
https://tntenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=744577 |
| Start Date | November 17, 2025 15:30 |
| End Date |
Expired
27/11/2025
Expired 320 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
T off of the 110 kv psml to anpk and 110 kv psml to tkpt into lilo at aviyoor 110 kv ss
T off of the 110 kv psml to anpk and 110 kv psml to tkpt into lilo at aviyoor 110 kv ss
Read moreCapacity enhancement of 110 kv palakkadvennakkara 110kv dc line
Capacity enhancement of 110 kv palakkadvennakkara 110kv dc line from 220 kv substation palakkad to 110 kv substation vennakkara by reconductoring of acsr wolf to al59,195 sqmm including supply, installation testing and commissioning
Read moreDismantling, re-erection, and construction of 132 kv dc lilo of rongkhon ampati due to diversion of the 132 kv dc lilo of rongkhon ampati at the 132/33 kv praharinagar substation (between tower locations 8 and 12) (line length 1.85 ckm)
Dismantling, re-erection, and construction of 132 kv dc lilo of rongkhon ampati due to diversion of the 132 kv dc lilo of rongkhon ampati at the 132/33 kv praharinagar substation (between tower locations 8 and 12) (line length 1.85 ckm)
Read moreCustom bid for services - supply of 33 kv isolator connectors twin panther and dc 2 26 crc spray for 132 kv substations
Custom bid for services - supply of 33 kv isolator connectors twin panther and dc 2 26 crc spray for 132 kv substations
Read moreDcw-providing scaffolding works in and around for cable termination tower at loc no.25, 26 for deviation of existing 66 kv thanjavur-pirattiyur eht line and at loc no.15a, 15b 110 kv trichy-thuvakudi and 110 kv alundur-thuvakudi dc line at panjapur.
Dcw-providing scaffolding works in and around for cable termination tower at loc no.25, 26 for deviation of existing 66 kv thanjavur-pirattiyur eht line and at loc no.15a, 15b 110 kv trichy-thuvakudi and 110 kv alundur-thuvakudi dc line at panjapur.
Read moreLaying of 33 kv 1 x 630 sq mm xlpe ug cable for second source of poonamallee mtc depot ev station from porur srmc 110 kvss reach i ch 0 to 2500 m route length 2500 m
Laying of 33 kv 1 x 630 sq mm xlpe ug cable for second source of poonamallee mtc depot ev station from porur srmc 110 kvss reach i ch 0 to 2500 m route length 2500 m
Read moreLaying of 33 kv 1 x 630 sq mm xlpe ug cable for second source of poonamallee mtc depot ev station from porur srmc 110 kvss reach iii ch 5000 to 7500 m route length 2500 m
Laying of 33 kv 1 x 630 sq mm xlpe ug cable for second source of poonamallee mtc depot ev station from porur srmc 110 kvss reach iii ch 5000 to 7500 m route length
Read moreLaying of 33 kv 1 x 630 sq mm xlpe ug cable for second source of poonamallee mtc depot ev station from porur srmc 110 kvss reach ii ch 2500 to 5000 m route length 2500 m
Laying of 33 kv 1 x 630 sq mm xlpe ug cable for second source of poonamallee mtc depot ev station from porur srmc 110 kvss reach ii ch 2500 to 5000 m route length 2500 m
Read moreLaying of 33 kv 1 x 630 sq mm xlpe ug cable for second source of poonamallee mtc depot ev station from porur srmc 110 kvss reach iv ch 7500 to 9690 m route length 2190 m
Laying of 33 kv 1 x 630 sq mm xlpe ug cable for second source of poonamallee mtc depot ev station from porur srmc 110 kvss reach iv ch 7500 to 9690 m route length 2190 m
Read moreConstruction of 110kv lilo line to 110kv mukunda sub-station by utilizing 110kv dc towers from the tapping point of existing 110kv munirabad-2 line for a distance of 12.62 kms along with construction of terminal bay at 110/11kv mukkunda sub-station in sindhanur taluk, raichur district. (including civil works) of all materials/equipments
Construction of 110kv lilo line to 110kv mukunda sub-station by utilizing 110kv dc towers from the tapping point of existing 110kv munirabad-2 line for a distance of 12.62 kms along with construction of terminal bay at 110/11kv mukkunda sub-station in sindhanur taluk, raichur district. (including civil works) of all materials/equipments
Read moreof your Industry type