Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
About Tender
🔧 Procurement Notice: Transwitch Unit Repair And Reconditioning 🔧 Central Coalfields Limited (Cccl), A Public Sector Undertaking, Is Soliciting Bids For The Complete Repairing And Reconditioning Of One (1) No. 315 Kva, 3.3 Kv/550 V Transwitch Unit, Model 'Mefta', Installed As Part Of The 'Topa' Project Under The Kuju Area. 📅 Bid Submission Deadline: June 14, 2024, 6:55 Pm Interested Bidders Must Submit A Tender Security Of Inr 49,000. No Tender Fee Is Payable. Bidders Are Expected To Provide A Detailed Technical And Financial Proposal, Including The Scope Of Work, Methodology, And Cost Estimates, Adhering To The Specifications And Standards Required For The Reconditioning Of The Transwitch Unit. Keywords: Transwitch Unit, Repair And Reconditioning, Central Coalfields Limited, Public Sector Undertaking, Electrical Equipment, Kuju Area, Tender, Bid Security| Particulars | Details |
|---|---|
| Title |
Complete Repairing And Reconditioning Of One No. 315 Kva, 3.3 Kv/550 V Transwitch Unit Make Mefta Installed A Topa Project Under Kuju Area .
|
| Description |
Complete Repairing And Reconditioning Of One No. 315 Kva, 3.3 Kv/550 V Transwitch Unit Make Mefta Installed A Topa Project Under Kuju Area .
|
| Organisation | Central Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2024_CCL_309739_1 |
|
Reference Number |
GM (K)/EnM/eTender/24-25/61 |
| Tender Fee | 0 |
| EMD | 4900 |
| Tender Value | - |
| Place | GM Unit, Kuju |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=320930 |
| Start Date | June 05, 2024 00:25 |
| End Date |
Expired
14/06/2024
Expired 852 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Flameproof transwitch unit (flp tsu) 315kva, 3.3kv/550v (or 525v),flameproof switch board panel comprising of seven flameproof 3.3kv, 400a vcb,flameproof switch board panel comprising of four flameproof 3.3kv, 400a vcb,flameproof vacuum circuit breaker 3.3kv, 400a,flameproof air circuit breaker 400a, 550v,flameproof air circuit breaker 200a, 550v,flameproof air circuit breaker 100a, 550v
Flameproof transwitch unit (flp tsu) 315kva, 3.3kv/550v (or 525v),flameproof switch board panel comprising of seven flameproof 3.3kv, 400a vcb,flameproof switch board panel comprising of four flameproof 3.3kv, 400a vcb,flameproof vacuum circuit breaker 3.3kv, 400a,flameproof air circuit breaker 400a, 550v,flameproof air circuit breaker 200a, 550v,flameproof air circuit breaker 100a, 550v
Read moreComplete rewinding and repairing of primary and secondary breaker of andrew yule make 315 kva 3.3kv-550v sl no sspay03 transwitch transformer at shyamsundarpur colliery
Complete rewinding and repairing of primary and secondary breaker of andrew yule make 315 kva 3.3kv-550v sl no sspay03 transwitch transformer at shyamsundarpur colliery
Read moreA)complete repairing/rewinding of 63kva 3 phase 3.3kv/230 volt transformer, make- transgietz enterprises, sl. no.-224 installed in dakra mines in respect of dakra project. b) preventive maintenance of 100kva 3.3kv/440v transformer sl. no.- local sl.
A)complete repairing/rewinding of 63kva 3 phase 3.3kv/230 volt transformer, make- transgietz enterprises, sl. no.-224 installed in dakra mines in respect of dakra project. b) preventive maintenance of 100kva 3.3kv/440v transformer sl. no.- local sl.
Read more(i)for maintenance of one no.1 mva 6.6kv/550v transformer installed at loyabad colliery make-ece,asset sl.no.arn/14 lbc(ii)complete rewinding and overhauling of a 750 kva power transformer 6.6kv/550v at 5 pit substation of lbc make-ece asset.no.loy/e
(i)for maintenance of one no.1 mva 6.6kv/550v transformer installed at loyabad colliery make-ece,asset sl.no.arn/14 lbc(ii)complete rewinding and overhauling of a 750 kva power transformer 6.6kv/550v at 5 pit substation of lbc make-ece asset.no.loy/e
Read moreAuxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read moreComplete repairing and reconditioning of one no. 315kva, 3.3kv/550v transwitch unit make andrew yule installed at topa project under kuju area.
Complete repairing and reconditioning of one no. 315kva, 3.3kv/550v transwitch unit make andrew yule installed at topa project under kuju area.
Read moreRepairing/recondition of 315kva,3.3kv/550v flp transwitch unit,mefta make and 80kw,550v motor make crompton greaves of topa ocp under kuju area.
Repairing/recondition of 315kva,3.3kv/550v flp transwitch unit,mefta make and 80kw,550v motor make crompton greaves of topa ocp under kuju area.
Read moreRepairing and reconditioning of one no. 315kva,3.3kv/550v transwitch unit andrew yule make of topa project under kuju area.
Repairing and reconditioning of one no. 315kva,3.3kv/550v transwitch unit andrew yule make of topa project under kuju area.
Read moreRepairing/ reconditioning of 315kva,3.3kv/550v flp transwitch unit,gec make, sl. no.ct3950/b22522 installed at 10 no. substation of sarubera of sarubera project under kuju area.
Repairing/ reconditioning of 315kva,3.3kv/550v flp transwitch unit,gec make, sl. no.ct3950/b22522 installed at 10 no. substation of sarubera of sarubera project under kuju area.
Read moreComplete rewinding repairing of 315kva, 3.3kv 550v 440v transwitch unit (tsu) of shyamsundarpur colliery under bankola area.
Complete rewinding repairing of 315kva, 3.3kv 550v 440v transwitch unit (tsu) of shyamsundarpur colliery under bankola area.
Read moreof your Industry type