Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
About Tender
🏥 Procurement Opportunity: Mri Conditional Everolimus Drug Eluting Stent 💉 The Department Of Military Affairs, Ministry Of Defence, Is Seeking Bids For The Supply Of Mri Conditional Everolimus Drug Eluting Stents With Bioabsorbable Polymer And Low Thrombogenicity Features. 🔬 🗓️ Deadline: June 13, 2024, 4:00 Pm Suppliers Must Provide Detailed Bids That Meet The Technical Specifications And Regulatory Requirements As Outlined In The Tender Document. Keywords: Mri Conditional Stent, Everolimus Drug Eluting Stent, Bioabsorbable Polymer, Low Thrombogenicity, Department Of Military Affairs, Ministry Of Defence, Medical Procurement, Stent Suppliers| Particulars | Details |
|---|---|
| Title |
Mri Conditional Everolimus Drug Eluting Cobalt Chromium Stent With Biodegradable Polymer And Low St
|
| Description |
|
| Organisation | Department of Military Affairs | Ministry of Defence |
| Tender Id | GEM/2024/B/4909420 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | May 23, 2024 16:01 |
| End Date |
Expired
13/06/2024
Expired 855 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
Technical Evaluation Results
| S.No. | Seller Name | Offered Item | Participated On | MSE/MII Status | Status |
|---|---|---|---|---|---|
| 1 | A B ENTERPRISE | Make : VEIVA SCIENTIFIC Model : REIVAS EPITOME Title : Mri Conditional Everolimus Drug Eluting Cobalt Chromium Stent With Biodegradable Polymer And Low Str | 13-06-2024 14:25:31 | N/A | Evaluated |
| 2 | ANSH THERAPEUTICS PRIVATE LIMITED | Make : ENVISION SCIENTIFIC Model : Abluminus Title : Sirolimus Drug Eluting Stent, Biodegrabable Polymer Coated Cobalt Chromium, Open Cell Design, Plla-p | 12-06-2024 18:26:39 | N/A | Evaluated |
| 3 | APICAP SCIENTIFIC | Make : RIVARP MEDICAL PVT LTD Model : SIRONIX Title : MRI CONDITIONAL EVEROLIMUS DRUG ELUTING COBALT CHROMIUM STENT WITH BIODEGRADABLE POLYMER AND LOW STR | 13-06-2024 12:09:17 | N/A | Evaluated |
| 4 | CONTINENTAL DRUG STORES | Make : ISAR SUMMIT/TRANSLUMINA Model : ISAR SUMMIT Title : COBALT CHROMIUM EVEROLIMUS ELUTING 4TH GENERATION CORONARY STENT ASSORTED SIZES | 13-06-2024 13:21:43 | N/A | Evaluated |
| 5 | Evolution Health Science | Make : iVascular Model : ANGIOLITE Title : Mri Conditional Everolimus Drug Eluting Cobalt Chromium Stent With Biodegradable Polymer And Low Str | 13-06-2024 14:48:16 | N/A | Evaluated |
| 6 | KAIROS HEALTH | Make : PTCA STENT EVEROLIMUS Model : PTCA STENT EVEROLIMUS Title : PTCA STENT EVEROLIMUS | 13-06-2024 15:22:54 | N/A | Evaluated |
| 7 | M/s ALPINE BIOMEDICS | Make : Model : Title : | 11-06-2024 15:55:26 | N/A | Evaluated |
| 8 | NEXGEN ENTERPRISES | Make : TERUMO Model : Ultimaster Nagomi Stent Title : Ultimaster Nagomi Stent | 12-06-2024 17:32:41 | N/A | Evaluated |
| 9 | OMNIFIC HEALTHCARE PRIVATE LIMITED | Make : EVEROLIMUS DRUG ELUTING COBALT CHROMIUM STENT Model : EVEROLIMUS DRUG ELUTING COBALT CHROMIUM STENT Title : EVEROLIMUS DRUG ELUTING COBALT CHROMIUM STENT | 12-06-2024 18:42:25 | N/A | Evaluated |
| 10 | Ria Pharmaceuticals And Surgicals | Make : Meril Life Sciences India Pvt. Limited Model : EVERMINE50 EVEROLIMUS STENT Title : EVERMINE50 EVEROLIMUS STENT | 12-06-2024 16:58:53 | N/A | Evaluated |
| 11 | VISKHO HEALTHCARE PRIVATE LIMITED | Make : XIENCE ALPINE-ABBOTT Model : XIENCE ALPINE Title : XIENCE ALPINE | 13-06-2024 12:08:43 | N/A | Evaluated |
Vascular sheath radial artery 5 fr,vascular sheath radial artery 6 fr,vascular sheath femoral artery 6 fr,vascular sheath femoral artery 7 fr,vascular sheath femoral artery 8 fr,pressure monitoring line 200 cm maletofemale,high pressure line mf 120cm braided 1200 psi,manifold 2 port,unolock syringe 10 ml,temporary pacing wire 6 fr,puncture needle 18g,ptca guidewire hydrophilic 0.014 180 cm 2 mm distal tip,ptca guide wire standard,ptca guidewire hydrophilic,drug eluting stent everolimus cocr 100 micrometre usfda,drug eluting stent sirolimus cocr 100 micrometre usfda,drug eluting stent zotarolimus cocr 100 micrometre usfda,drug eluting stent biolimus a9 cocr 100 micrometre usfda,drug eluting stent everolimus ptcr 100 micrometre usfda,drug eluting stent sirolimus ptcr 100 micrometre usfda,drug eluting stent zotarolimus ptcr 100 micrometre usfda,drug eluting stent biolimus a9 ptcr 100 micrometre usfda,double lumen ptmc balloon dilatation catheter with complete accessories,mullins sheath 8 fr,guide wire 0.032 x 26
Vascular sheath radial artery 5 fr,vascular sheath radial artery 6 fr,vascular sheath femoral artery 6 fr,vascular sheath femoral artery 7 fr,vascular sheath femoral artery 8 fr,pressure monitoring line 200 cm maletofemale,high pressure line mf 120cm braided 1200 psi,manifold 2 port,unolock syringe 10 ml,temporary pacing wire 6 fr,puncture needle 18g,ptca guidewire hydrophilic 0.014 180 cm 2 mm distal tip,ptca guide wire standard,ptca guidewire hydrophilic,drug eluting stent everolimus cocr 100 micrometre usfda,drug eluting stent sirolimus cocr 100 micrometre usfda,drug eluting stent zotarolimus cocr 100 micrometre usfda,drug eluting stent biolimus a9 cocr 100 micrometre usfda,drug eluting stent everolimus ptcr 100 micrometre usfda,drug eluting stent sirolimus ptcr 100 micrometre usfda,drug eluting stent zotarolimus ptcr 100 micrometre usfda,drug eluting stent biolimus a9 ptcr 100 micrometre usfda,double lumen ptmc balloon dilatation catheter with complete accessories,mullins sheath 8 fr,guide wire 0.032 x 26
Read moreEverolimus drug eluting coronary stent on platinum chromium platform - bioabsorable with abluminal coating. additional connectors 4/5 in the proximal 2 segments. strut thickness 1.5 mm. available sizes 2.25 mm to 5.0 mm in diameter, 8.0 mm to 48 mm in length. 2 connector design throughout the body mecd >7.0 mm.
Everolimus drug eluting coronary stent on platinum chromium platform - bioabsorable with abluminal coating. additional connectors 4/5 in the proximal 2 segments. strut thickness 1.5 mm. available sizes 2.25 mm to 5.0 mm in diameter, 8.0 mm to 48 mm in length. 2 connector design throughout the body mecd >7.0 mm.
Read moreSmall arterial sheath,medium arterial sheath,large arterial sheath,2 way manifold,y connector,0.35 inch straight tipped ptfe wire regular length,0.35 inch ptfe j tipped wire exchange length,puncture needle radial artery,puncture needle femoral artery,polymer jacketed 0.35inch wire regular length,polymer jacketed 0.35inch wire exchange length,tavi valve,thrombus aspiration catheter,pigtail catheter,3 way manifold,transcatheter implantable pulmonary valve,inflation device,semicomplaint coronary balloons,noncomplaint coronary balloons,sirolimus eluting coronary stents size 4.5mm diameter or more,everolimus drug eluting stent,polymer free coronary stent
Small arterial sheath,medium arterial sheath,large arterial sheath,2 way manifold,y connector,0.35 inch straight tipped ptfe wire regular length,0.35 inch ptfe j tipped wire exchange length,puncture needle radial artery,puncture needle femoral artery,polymer jacketed 0.35inch wire regular length,polymer jacketed 0.35inch wire exchange length,tavi valve,thrombus aspiration catheter,pigtail catheter,3 way manifold,transcatheter implantable pulmonary valve,inflation device,semicomplaint coronary balloons,noncomplaint coronary balloons,sirolimus eluting coronary stents size 4.5mm diameter or more,everolimus drug eluting stent,polymer free coronary stent
Read moreVascular suture mediated closure and repair system sterile with 3 point 0 mono filamen polypropylene suture 300 series stainless steel needles,non complaint ballon,holter patches disposable nc 1340 web cardio 7 days er proof wireless multiday holter patch sp7,everolimus eluting balloon mounted platinum chromium coronary stent system assorted size,flexible lead free radiation shield,high pressure 3 port manifold,dedicated kit angiography for radial,coronary angioplasty kit,zotarolimus eluting balloon expandable cobalt alloy coronary stent system with continuous sinusoidal design assorted size,terumo angiography guide wire 0 point 035 x 150 cm j tip,hp laser toner cartridge for hp laser 103a
Vascular suture mediated closure and repair system sterile with 3 point 0 mono filamen polypropylene suture 300 series stainless steel needles,non complaint ballon,holter patches disposable nc 1340 web cardio 7 days er proof wireless multiday holter patch sp7,everolimus eluting balloon mounted platinum chromium coronary stent system assorted size,flexible lead free radiation shield,high pressure 3 port manifold,dedicated kit angiography for radial,coronary angioplasty kit,zotarolimus eluting balloon expandable cobalt alloy coronary stent system with continuous sinusoidal design assorted size,terumo angiography guide wire 0 point 035 x 150 cm j tip,hp laser toner cartridge for hp laser 103a
Read moreMri conditional everolimus drug eluting cobalt chromium stent with biodegradable polymer and low st
Read more
Biodegradable polymer coated cobalt chromium sirolimus drug eluting stent system with ultrathin 60,
Read more
Biodegradable polymer coated cobalt chromium sirolimus drug eluting stent system with ultrathin 60,
Read more
Usfda dgci approved everolimus drug eluting third generation cobalt chromium coronary stent assorte
Read more
of your Industry type