Tender Details
Particulars | Details |
---|---|
Title |
Implant For Total Knee Replacement Set H [Implant For Total Knee Replacement Set Hi Flex Knee Consisiting Primary Knee Replacement Femoral Component Hi Flex 1 ,Primary Knee Replacement Systyem Tibial Component Titanium Alloy Coated 1, Primary Knee Replacement System Inert 1]
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106560972 |
Reference Number |
H3245402 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Jaipur |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/122024/106560972/viewNitPdf_4813815.pdf |
Start Date | December 22, 2024 23:34 |
End Date |
26/12/2024 ( Expired 139 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Implant for total knee replacement set h [implant for total knee replacement set hi flex knee consisiting primary knee replacement femoral component hi flex 1 ,primary knee replacement systyem tibial component titanium alloy coated 1, primary knee replacement system inert 1]
For complete deion and other details, please refer to tender
Read morePrimary tkr cr knee consisting of 1. non porous coated femoral component curciate retaining with separate left and right components cobalt chromium make in various sizes 2. tibial component cobalt chromium make with anatomical regular tray and size variations. 3. highly crossed linked poly (c.s) 4.patella resurfacing component . 5. 40gm slow setting bone cement.6. pulse lavage -01no, 7.saw blade-01, 8.should supply all implants and instrumentation at the time of surgery 9. bis /european ce/us
For complete deion and other details, please refer to tender
Read moreModular bipolar hip prosthesis set consisting of femoral stem-01, titanium alloy make, proximal stem h a coated , morphometric wedge design which fits for a wide range of femoral canal and to have two neck angles, 02- femoral head cobalt chromium-1no. 03-bipolar component cobalt with highly cross lined poly lining
For complete deion and other details, please refer to tender
Read moreImplant for total knee replacement set h [implant for total knee replacement set hi flex knee consisiting primary knee replacement femoral component hi flex 1 ,primary knee replacement systyem tibial component titanium alloy coated 1, primary knee replacement system inert 1]
For complete deion and other details, please refer to tender
Read moreAdaptor sleeve for revision tkr specifications- 1 should be made up of cocr or medical grade titanium 2 should be compatible with existing knee revision system or tc3 3 should be available in various sizes for both femur and tibia 4 should be available in uncemented and cemented options 5 firm should be reputed with long term market standing. 6 compatible with revision system available in the hospital 7 company should supply all required instrumentations and implant along with t
For complete deion and other details, please refer to tender
Read moreModular bipolar hip prosthesis set consisting of femoral stem-01, titanium alloy make, proximal stem h a coated , morphometric wedge design which fits for a wide range of femoral canal and to have two neck angles, 02- femoral head cobalt chromium-1no. 03-bipolar component cobalt with highly cross lined poly lining
For complete deion and other details, please refer to tender
Read morePrimary tkr cr knee consisting of 1. non porous coated femoral component curciate retaining with separate left and right components cobalt chromium make in various sizes 2. tibial component cobalt chromium make with anatomical regular tray and size variations. 3. highly crossed linked poly (c.s) 4.patella resurfacing component . 5. 40gm slow setting bone cement.6. pulse lavage -01no, 7.saw blade-01, 8.should supply all implants and instrumentation at the time of surgery 9. bis /european ce/us
For complete deion and other details, please refer to tender
Read moreModular bipolar hip prosthesis set consisting of femoral stem-01, titanium alloy make, proximal stem h a coated , morphometric wedge design which fits for a wide range of femoral canal and to have two neck angles, 02- femoral head cobalt chromium-1no. 03-bipolar component cobalt with highly cross lined poly lining
For complete deion and other details, please refer to tender
Read morePrimary tkr cr knee consisting of 1. non porous coated femoral component curciate retaining with separate left and right components cobalt chromium make in various sizes 2. tibial component cobalt chromium make with anatomical regular tray and size variations. 3. highly crossed linked poly (c.s) 4.patella resurfacing component . 5. 40gm slow setting bone cement.6. pulse lavage -01no, 7.saw blade-01, 8.should supply all implants and instrumentation at the time of surgery 9. bis /european ce/us
For complete deion and other details, please refer to tender
Read moreAdaptor sleeve for revision tkr specifications- 1 should be made up of cocr or medical grade titanium 2 should be compatible with existing knee revision system or tc3 3 should be available in various sizes for both femur and tibia 4 should be available in uncemented and cemented options 5 firm should be reputed with long term market standing. 6 compatible with revision system available in the hospital 7 company should supply all required instrumentations and implant along with t
For complete deion and other details, please refer to tender
Read moreof your Industry type