Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Repairing Or Rewinding Of 01 No. 100 Kva Lighting Transformer, 02 Nos 25 Kva Lighting Transformer, 01 No 3 Phase Ac Induction Motor Of 45 Kw, 415 Volt At Bws (Eand M), Jayant Project
|
| Description |
Repairing Or Rewinding Of 01 No. 100 Kva Lighting Transformer, 02 Nos 25 Kva Lighting Transformer, 01 No 3 Phase Ac Induction Motor Of 45 Kw, 415 Volt At Bws (Eand M), Jayant Project
|
| Organisation | Northern Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2024_NCL_300565_1 |
|
Reference Number |
NCL/JNT/EandM/Tender/23-24/789 dtd.06.02.2024 |
| Tender Fee | 0 |
| EMD | 2400 |
| Tender Value | - |
| Place | BWS (EandM), Jayant Project |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=311337 |
| Start Date | February 07, 2024 14:30 |
| End Date |
Expired
19/02/2024
Expired 972 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Transformer 2kva 1phase 415 220v,transformer 200va 3phase yn yn0575 110v,transformer 3phase dyn11575 165v,transformer 4 kva 415 165v,transformer control 2kva three phases 50hz lv1 415v hv1 575v
Transformer 2kva 1phase 415 220v,transformer 200va 3phase yn yn0575 110v,transformer 3phase dyn11575 165v,transformer 4 kva 415 165v,transformer control 2kva three phases 50hz lv1 415v hv1 575v
Read moreRepairing of 500 kva, 11 kv 440 v, lighting transformer and 315 kva transformer at sadariyadih and main substation abocp
Repairing of 500 kva, 11 kv 440 v, lighting transformer and 315 kva transformer at sadariyadih and main substation abocp
Read moreRate contract for rewinding of different rating of 3-phase, 415 v, sq. cage lt induction motor of ph-i, ii, iii, at sgtps, mppgcl, birsinghpur.
Rate contract for rewinding of different rating of 3-phase, 415 v, sq. cage lt induction motor of ph-i, ii, iii, at sgtps, mppgcl, birsinghpur.
Read more10 kva,25 kv/240 volt, oil filled, outdoor type single phase, auxiliary transformer along with all fittings
10 kva,25 kv/240 volt, oil filled, outdoor type single phase, auxiliary transformer along with all fittings
Read moreRepairing of 750 kva, 11kv 6.6kv 440v, lighting transformer make kva process transformers p ltd at mpl and 500 kva,11kv 440v,make mandb switchgears ltd transformer at nadkhurkee main substation abocp..
Repairing of 750 kva, 11kv 6.6kv 440v, lighting transformer make kva process transformers p ltd at mpl and 500 kva,11kv 440v,make mandb switchgears ltd transformer at nadkhurkee main substation abocp..
Read moreComplete rewinding and repairing of primary and secondary breaker of andrew yule make 315 kva 3.3kv-550v sl no sspay03 transwitch transformer at shyamsundarpur colliery
Complete rewinding and repairing of primary and secondary breaker of andrew yule make 315 kva 3.3kv-550v sl no sspay03 transwitch transformer at shyamsundarpur colliery
Read moreSupply, erection/installation, testing a [supply, erection/installation, testing and commissioning of induction heater 25 kva, 415 v, 50hz with swing arm arrangement for assemblies of suspension tubes parts, as per annexure attached.]
Supply, erection/installation, testing a [supply, erection/installation, testing and commissioning of induction heater 25 kva, 415 v, 50hz with swing arm arrangement for assemblies of suspension tubes parts, as per annexure attached.]
Read moreStep down 9 kva transformer, 750/415/190 volts ac, vector configuration star- star as per rdso specification rdso/pe/spec/tl/0158 -2010 (rev. 1 ) type-i or latest.
Step down 9 kva transformer, 750/415/190 volts ac, vector configuration star- star as per rdso specification rdso/pe/spec/tl/0158 -2010 (rev. 1 ) type-i or latest.
Read moreRewinding and repair of 63 kva transformer installed at ips-3 (rajiv colony) and replacement of mccb at ips-2 (rajiv colony),jammu contract no sdj/w/104/2026-27
Rewinding and repair of 63 kva transformer installed at ips-3 (rajiv colony) and replacement of mccb at ips-2 (rajiv colony),jammu contract no sdj/w/104/2026-27
Read moreComplete repairing and rewinding of 11kv 400v, 500kva, 3 phase lighting transformer, make ngef, sl. no. 28.0002.2206, for providing domestic power supply to sector 6, matigarha dam site under block-ii area.
Complete repairing and rewinding of 11kv 400v, 500kva, 3 phase lighting transformer, make ngef, sl. no. 28.0002.2206, for providing domestic power supply to sector 6, matigarha dam site under block-ii area.
Read moreof your Industry type