Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Contactor Aux.Contacts 2 No2 Nc, Coil Voltage 110 Volt Dc For Use In 50 Percent Off Light Circuit And Battery Charger Failure Relay Of Emu/Memu
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106485675 |
|
Reference Number |
20241735 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Kolkata |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/122024/106485675/viewNitPdf_4787247.pdf |
| Start Date | November 27, 2024 19:27 |
| End Date |
Expired
27/12/2024
Expired 656 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read moreContactor aux.contacts 2no2nc, coil voltage 110 volt dc for use in 50 percent off light circuit and battery charger failure relay of emu/memu
For complete deion and other details, please refer to tender
Read moreContactor aux.contacts 2no2nc, coil voltage 110 volt dc for use in 50 percent off light circuit and battery charger failure relay of emu/memu
For complete deion and other details, please refer to tender
Read moreSimplified battery charger for emu/memu
For complete deion and other details, please refer to tender
Read moreSimplified battery charger for emu/memu
For complete deion and other details, please refer to tender
Read moreContactor operating coil 110 volt
For complete deion and other details, please refer to tender
Read moreContactor ls 45k4.00 dc 110 volt
For complete deion and other details, please refer to tender
Read more110 volt 40 ah battery charger
For complete deion and other details, please refer to tender
Read moreTrack feed battery charger input voltage 110 volt
For complete deion and other details, please refer to tender
Read moreof your Industry type