Tender Details
Check your funding eligibility in 2 minutes.
Answer a few questions and our team will contact you with your best options.
Particulars | Details |
---|---|
Title |
Attending Heavy/Minor Leakages On 1050/762/600mm Dia Psc/Ms Gravity Mains From Sanathnagar Also For Chokages/Repairs/Overhauling Of Valves And Jungle Cutting Etc., Under Annual Maintenance Contract For The Period Of Two Years Under Sanathnagar Section Td Iv, Control Room
|
Description |
Attending Heavy/Minor Leakages On 1050/762/600mm Dia Psc/Ms Gravity Mains From Sanathnagar Also For Chokages/Repairs/Overhauling Of Valves And Jungle Cutting Etc., Under Annual Maintenance Contract For The Period Of Two Years Under Sanathnagar Section, Sub Division No. Ii Of Transmission Div.Iv, Control Room
|
Organisation | Information Technology Electronics and Communication Department Telangana | State Govt. and UT |
Tender Id |
AAAAAAAAAA Login to view |
Reference Number |
AAAAAAAAAA Login to view |
Tender Fee | 3056 |
EMD | 86309 |
Tender Value | |
Place | TS |
Link |
AAAAAAAAAA Login to view |
Start Date | June 26, 2025 22:30 |
End Date |
03/07/2025 ( 5 days left ) Search Similar tenders? |
Join for More Relevant Opportunities |
Attending heavy leakages on 1200/800/7008600/450/400/300mm dia psc/ms/ci/di gravity mains from alwal to sainikpuri attending also minor leakages, chokages/repairs/overhauling of valves and jungle cutting etc., under annual maintenance for the period of two years under sainikpuri section, sd-iii, td-iv control room
Attending heavy leakages on 1200/800/700/600/450/300mm dia psc/ms/ci/di gravity mains from alwal to sainikpuri attending also minor leakages chokages/repairs/overhauling of valves and jungle cutting etc., under annual maintenance contract for the period of two years under sainikpuri section, sub division no. ii of transmission div.iv, control room
Read moreAttending heavy leakages on 1100/1000/600/400/350mm dia psc/ms/di gravity /pumping mains from alwal also attending minor, leakages, chokages/repairs/overhauling of valves and jungle cutting etc., under annual maintenance contract for the period of two years under alwal section sd.no.iii, td-iv, control room
Attending heavy leakages on 1100/1000/600/400/350mm dia psc/ms/di gravity/pumping mains from alwal also attending minor, leakages, chokages/repairs/overhauling of valves and jungle cutting etc., under annual maintenance contract for the period of two years under alwal section, sub division no. iii of transmission div.iv, control room
Read moreAttending heavy/minor leakages on 1050/762/600mm dia psc/ms gravity mains from sanathnagar also for chokages/repairs/overhauling of valves and jungle cutting etc., under annual maintenance contract for the period of two years under sanathnagar section td-iv, control room
Attending heavy/minor leakages on 1050/762/600mm dia psc/ms gravity mains from sanathnagar also for chokages/repairs/overhauling of valves and jungle cutting etc., under annual maintenance contract for the period of two years under sanathnagar section, sub division no. ii of transmission div.iv, control room
Read moreAttending heavy/minor leakages on 1200/900/800/700mm dia psc/ms gravity mains from hydernagar also for chokages/repairs/overhauling of valves and jungle cutting etc., under annual maintenance contract for the period of two years under hydernagar section, sd.no.iii of td-iv, control room
Attending heavy/minor leakages on 1200/900/800/700mm dia psc/ms gravity mains from hydernagar also for chokages/repairs/overhauling of valves and jungle cutting etc., under annual maintenance contract for the period of two years under hydernagar section, sub division no. iii of transmission div.iv, control room
Read moreAttending heavy/minor leakages on 1200/1000/1143/800/700/600mm dia psc/ms/di gravity/ pumping mians from lingampally also for chokages/repairs/overhauling of valves and jungle cutting etc., under annual maintenance contract for the period of two years under lingampally section, sd.ii, td-iv, control room
Attending heavy/minor leakages on 1200 / 1000 / 1143 / 800 /700/600mm dia psc/ms/di gravity/pumping mains from lingampally also for chokages/repairs/overhauling of valves and jungle cutting etc., under annual maintenance contract for the period of two years under lingampally section, sub division no.ii of transmission div.iv, control room
Read moreReplacement of damaged 900mm dia di/df butterfly valve with new valve on existing 1200mm dia psc gravity main ppe line from prashasan nagar to lingampally at film chamber x raods film nagar under lingampally section, sd-ii, td-iv, control room
Replacement of damaged 900mm dia di df butterfly valve with new valve existing on 1200mm dia psc gravity main pipeline from prashasan nagar to lingampally at film chamber x roads, film nagar under lingampally section s.d-ii transmission division - iv, control room, secunderabad.
Read moreM,s,d,f and comm of 900mm dia di/df bf valve on 1143mm dia ci gravity main pipeline from lpally to sanathnagar near kamuni cheruvu at khaithlapur flyover to improve water supply to safdarnagar yousufnagar and rajiv gandhi nagar areas of o and m div.ix, td-iv, control room.
Manufacturing, supply, delivery, fixing and commissioning of 900mm dia di/df butterfly valve on 1143mm dia psc gravity main pipeline from lingampally to sanathnagar near kamuni cheruvu at kaithlapur flyover to improve water supply to safdar nagar, yousuf nagar and rajiv gandhi nagar areas under lingampally section, s.d-ii, transmission division - iv, control room, secunderabad.
Read moreShifting of 200/150mm dia double kinetic air valves existing on 1500mm dia ms gravity main of kdwsp phase-iii ring main-ii and 800mm dia psc/ms of pocharam pipeline for facilitating development road widening work at nfc circle by ghmc under moula-ali section, sd-iii, td-iii, sahebnagar
Shifting of 200/150mm dia double kinetic air valves existing on 1500mm dia ms gravity main of kdwsp phase-iii ring main-ii and 800mm dia psc/ms of pocharam pipe line for facilitating development road widening work at nfc circle by ghmc under moula-ali section, sd-iii, trans.div.iii, sahebnagar.
Read moreAmc (i) 1600mm dia ph-iii and ph-iv ms pumping main from peddapur to singapur ( 18.00 kms), 300/200mm dia di breweries water supply line (8.00 kms) and peddapur campus under peddapur section (ii) ph-iii and ph-iv 2000mm dia rcc gravity mains from singapur to peddapur (27.00 kms) and singoor campus under singapur section, amc for the period of two (2) years under sd-ii, peddapur, o and m division viii, patancheru
Annual maintenance (i) 1600mm dia phase-iii and phase-iv ms pumping mains from peddapur to singapur (18.00 kms), 300/200mm dia di breweries water supply line (8.00 kms) and peddapur campus under peddapur section (ii) ph-iii and ph-iv 2000mm dia rcc gravity mains from singapur to peddapur (27.00 kms) and singoor campus under singapoor section, annual maintenance contract for the period of two (2) years under sd_ii, peddapur o and m division no.viii, patancheru
Read moreM,s,d,l,lj,t and comm of 1000mm dia inline and out coated ms pipeline using 10mm thick ms plate along with required specials in place of damaged 1000mm dia psc moula ali to alwal reverse gravity main line from thanu factory store, kistamma enclave, alwal to m/s ok ceramics tiles and sanitary godown, kistamma enclave at alwal to avoid frequent leakages under alwal section, sd-iii, om div.no.xxi, control room
Manufacturing, supply, delivery, laying and commissioning of 1000mm dia inline and out coated ms pipeline using 10mm thick ms plate along with required specials in place of damaged 1000mm dia psc moula-ali to alwal reverse gravity main line from thanu fancy store, kistamma enclave, alwal to m/s ok ceramic tiles and sanitary godown, kistamma enclave at alwal to avoid frequent leakages under alwal section.sd-iii, o m div-xxi. control room, secunderabad. (slice-ii)