Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Transformer 415/110 V,200 Va To Intec Part No. Icac 071 For Roof Mounted Air
Conditioning System Of Cab Ac As Per Rdso Specification No. Rdso/2007/El/Spec/0055 Rev. 2
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106815884 |
|
Reference Number |
34255082 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Hazipur |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/092025/106815884/viewNitPdf_5102437.pdf |
| Start Date | September 04, 2025 03:04 |
| End Date |
Expired
22/09/2025
Expired 391 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Blower motor suitable for roof mounted packaged ac unit for electrical locomotive as per rdso spec no rdso/2007/el/spec/0055, rev-2 or latest.
Blower motor suitable for roof mounted packaged ac unit for electrical locomotive as per rdso spec no rdso/2007/el/spec/0055, rev-2 or latest.
Read moreBlower motor for roof mounted packaged ac unit of electric locomotives, type: aom, 0.12kw, supply 415v ac +/- 10 percent , 3-phase, 0.4 amps, rpm 1350, star connection, reference is: 325, freq. 50hz, as per rdso spec. no. rdso/2007/el/spec/0055, rev.- 2 with latest if any. make: lhp or star electric. specification :- - rdso spec. no. rdso/2007/el/spec/ 0055, rev.-2
Blower motor for roof mounted packaged ac unit of electric locomotives, type: aom, 0.12kw, supply 415v ac +/- 10 percent , 3-phase, 0.4 amps, rpm 1350, star connection, reference is: 325, freq. 50hz, as per rdso spec. no. rdso/2007/el/spec/0055, rev.- 2 with latest if any. make: lhp or star electric. specification :- - rdso spec. no. rdso/2007/el/spec/ 0055, rev.-2
Read moreHigh reach pantograph for electric locomotives. rdso/2007/el/spec/0054 rev-3 amendment 2 str: rdso/2008/el/str/0049 rev 2 .
High reach pantograph for electric locomotives. rdso/2007/el/spec/0054 rev-3 amendment 2 str: rdso/2008/el/str/0049 rev 2 .
Read moreTransformer 2kva 1phase 415 220v,transformer 200va 3phase yn yn0575 110v,transformer 3phase dyn11575 165v,transformer 4 kva 415 165v,transformer control 2kva three phases 50hz lv1 415v hv1 575v
Transformer 2kva 1phase 415 220v,transformer 200va 3phase yn yn0575 110v,transformer 3phase dyn11575 165v,transformer 4 kva 415 165v,transformer control 2kva three phases 50hz lv1 415v hv1 575v
Read moreHigh capacity compressor 1745/1750 lpm for conventional electric loco. as per rdso spec no. rdso/2018/el/spec/0137 rev 0 and str no. rdso/2007/el/str/0015 rev 1 for on board mounting on a base frame
High capacity compressor 1745/1750 lpm for conventional electric loco. as per rdso spec no. rdso/2018/el/spec/0137 rev 0 and str no. rdso/2007/el/str/0015 rev 1 for on board mounting on a base frame
Read moreProcurement of condenser motor, 0.15kw, supply 415v ac +/- 10 percent , 3-phase, 0.7amps, 63 frames, rpm1350, star connection, reference is: 325, frequency 50hz suitable for roof mounted cab ac unit in wag9 hc electric locomotives as per rdso spec. no. rdso/2007/el/spec/0055, rev. - 2, or latest if any.
Procurement of condenser motor, 0.15kw, supply 415v ac +/- 10 percent , 3-phase, 0.7amps, 63 frames, rpm1350, star connection, reference is: 325, frequency 50hz suitable for roof mounted cab ac unit in wag9 hc electric locomotives as per rdso spec. no. rdso/2007/el/spec/0055, rev. - 2, or latest if any.
Read moreEvaporator blower wheels (lhs & rhs) with housing, for cab ac of wag7 locomotives. note: 1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram / fedders lylord / sidwal fitted on conventional electric locos to rdso specification no: rdso/2007/el/spec/0055 rev.2 of nov 2007/revised on 07.10.2014. 2) one sample to be got approved before effecting bulk supply.
Evaporator blower wheels (lhs & rhs) with housing, for cab ac of wag7 locomotives. note: 1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram / fedders lylord / sidwal fitted on conventional electric locos to rdso specification no: rdso/2007/el/spec/0055 rev.2 of nov 2007/revised on 07.10.2014. 2) one sample to be got approved before effecting bulk supply.
Read moreAnti vibration mounting pad (avm) for 60 kva ,750/415 3 phi dry type distribution transformer for lhb type eog/ac coaches confirming to rdso specification no rdso/pe/spec/ac/0080-2007 (rev-2).
Anti vibration mounting pad (avm) for 60 kva ,750/415 3 phi dry type distribution transformer for lhb type eog/ac coaches confirming to rdso specification no rdso/pe/spec/ac/0080-2007 (rev-2).
Read moreRed/green led indication lamp for different modification (rdso/2022/el/ms/0487 ,for tmdds & rdso/2022/el/ms/0489,for hog )indication lamp of ac/dc-110v. note-red colour led lamp quantity-1 nos. and green colour led lamp quantity-1 nos.
Red/green led indication lamp for different modification (rdso/2022/el/ms/0487 ,for tmdds & rdso/2022/el/ms/0489,for hog )indication lamp of ac/dc-110v. note-red colour led lamp quantity-1 nos. and green colour led lamp quantity-1 nos.
Read moreof your Industry type