Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Dcs Plate 95 Degree Set Of 1 Plate 1 Richard Screw 4 Cortical Screw , Interchangeable Size.
Specifications
1.Should Be Made Up Of Medical Grade Titanium
2.Dcs Plate Should Be Of Locking Nature And Should Be Available In Required Length As Per The Case Needed.
3.Firm Should Supply The Required Length Of The Richard Head Screw
4. Firm Should Supply 3 Non Locking And 4 Locking Screws Of Various Length As Per Case Needed
5.Firm Should Be Reputed With Long Term Market Standing
6.Firm
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106498167 |
|
Reference Number |
62244655 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Mumbai CST |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/112024/106498167/viewNitPdf_4744855.pdf |
| Start Date | October 17, 2024 17:20 |
| End Date |
Expired
05/11/2024
Expired 711 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Medial tibial ostetomy plate titanium set consist of titanium medial tibial osteotomy plate of varying lengths with 6 locking screws and 2 cortical screws for fixation. screw axes should be 4 degrees with respect to plate shaft
Medial tibial ostetomy plate titanium set consist of titanium medial tibial osteotomy plate of varying lengths with 6 locking screws and 2 cortical screws for fixation. screw axes should be 4 degrees with respect to plate shaft
Read moreVa fibula plate (1 plate + 8 va locking screws + 6 cortical screws). spec: locking anatomical five hole variable angle distal fibula plate with 8(2.7 mm) va screw for head and shaft with two 3.5 cortical screw option in head for syndesmotic layer and 4(2.7mm) cortical screw, variable angle locking screw should have option to lock at + - 15 degree of axis in any direction complete range of size shape and side specific implant with instrumentation at the time of surgery. implant should be us fda
Va fibula plate (1 plate + 8 va locking screws + 6 cortical screws). spec: locking anatomical five hole variable angle distal fibula plate with 8(2.7 mm) va screw for head and shaft with two 3.5 cortical screw option in head for syndesmotic layer and 4(2.7mm) cortical screw, variable angle locking screw should have option to lock at + - 15 degree of axis in any direction complete range of size shape and side specific implant with instrumentation at the time of surgery. implant should be us fda
Read moreThe nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
Read moreTrochanteric femur nail advanced system one set. spec: (1) 9 mm to 12 mm diameter with inbuilt set screw. (2) should be capable of allowing cannulated screw or blade (one) with same hole in proximal part. (3) end of blade and screw should be porous to allow augmentation with 5 mm distal locking option (two). (4) material should be titanium molybdenum. (complete range of size shape and side specific implant with instrumentation should be available at the time of surgery).[ item code no.:s6155
Trochanteric femur nail advanced system one set. spec: (1) 9 mm to 12 mm diameter with inbuilt set screw. (2) should be capable of allowing cannulated screw or blade (one) with same hole in proximal part. (3) end of blade and screw should be porous to allow augmentation with 5 mm distal locking option (two). (4) material should be titanium molybdenum. (complete range of size shape and side specific implant with instrumentation should be available at the time of surgery).[ item code no.:s6155
Read moreInj. trabectedin 1mg [product should be available in the manufacturing firm?s approved product list of railway board ]
Inj. trabectedin 1mg [product should be available in the manufacturing firm?s approved product list of railway board ]
Read morePvc soft rubber tubing 8mm diameter, unsterile used for suction. should be 25 meter length in a single pack, pvc soft rubber tubing 6mm diameter, unsterile used for suction should be 180 meter length in a single pack
Pvc soft rubber tubing 8mm diameter, unsterile used for suction. should be 25 meter length in a single pack, pvc soft rubber tubing 6mm diameter, unsterile used for suction should be 180 meter length in a single pack
Read moreHumerus multilock nail set [srphc82414005-humerus multilock nail set should consist of reamed humerus nail with 4.5mm multilock blunt screws and 2 locking scrws. it should be available in diameter of 7,8,8.5,9.5mm with length ranging from 160 -300mm. itshould have polyethylene inlay with options of 3.5 and 4mm locking screws with complete set of instrumentation. unit:set]
Humerus multilock nail set [srphc82414005-humerus multilock nail set should consist of reamed humerus nail with 4.5mm multilock blunt screws and 2 locking scrws. it should be available in diameter of 7,8,8.5,9.5mm with length ranging from 160 -300mm. itshould have polyethylene inlay with options of 3.5 and 4mm locking screws with complete set of instrumentation. unit:set]
Read moreIndexable insert iso tnmg 220416 grade tn 4000 of widia or equivalent. note: 1. material should be procured from oem or authorized dealer of oem only. 2. firm should submit tender specific authorization from oem.
Indexable insert iso tnmg 220416 grade tn 4000 of widia or equivalent. note: 1. material should be procured from oem or authorized dealer of oem only. 2. firm should submit tender specific authorization from oem.
Read moreInj. oxaliplatin 100 mg [product should be available in the manufacturing firm s approved product list of railway board]item code no.: m260506 , ai 26-27
Inj. oxaliplatin 100 mg [product should be available in the manufacturing firm s approved product list of railway board]item code no.: m260506 , ai 26-27
Read moreof your Industry type