Tender Details

Particulars Details
Title
Installation And Commissioning Of 300 Kvar, 11 Kv Grade Capacitor Bank At 33 Kv Sub Station Of Nlocp Under Cv Area Xii, Bccl
Description
Installation And Commissioning Of 300 Kvar, 11 Kv Grade Capacitor Bank At 33 Kv Sub Station Of Nlocp Under Cv Area Xii, Bccl
Organisation Bharat Coking Coal Limited | Public Sector Undertakings
Tender Id 2025_BCCL_332526_1
Reference
Number
BCCL/CV/XII/EnM/ TENDER/2024-25/145
Tender Fee 0
EMD 2000
Tender Value -
Place 33/11KV NLOCP SUB-STATION
Link
View Original Tender Notice

https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=344713

Start Date March 14, 2025 18:30
End Date
Expired 22/03/2025

Expired 574 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Maintenance and reconditioning of 2 nos. vcb (11kv and 6.6kv, pce make), 2 nos. ocb switch (11kv, 800 amp, gec make), sf6 abb make breaker (33kv, 1250 amp), maintenance of ct, and repairing of 11kv capacitor bank control panel at central substation

Maintenance and reconditioning of 2 nos. vcb (11kv and 6.6kv, pce make), 2 nos. ocb switch (11kv, 800 amp, gec make), sf6 abb make breaker (33kv, 1250 amp), maintenance of ct, and repairing of 11kv capacitor bank control panel at central substation

Read more
Supply and delivery of 300 nos of 33kv v bracket, 300 nos of 33 kv top adaptor, 500 nos of porcelain guy insulator ht, 300 nos of 11 kv top adaptor for pcc pole 9m long, 300 nos of 11kv v bracket for pcc pole 9m long and 100 nos of 11kv v bracket 8m

Supply and delivery of 300 nos of 33kv v bracket, 300 nos of 33 kv top adaptor, 500 nos of porcelain guy insulator ht, 300 nos of 11 kv top adaptor for pcc pole 9m long, 300 nos of 11kv v bracket for pcc pole 9m long and 100 nos of 11kv v bracket 8m

Read more
Repair, maintenance, and installation of plant/ systems/equipments (version 2) - construction work of 01 number 33kv feeder bay for simrau including installing of capacitor bank isolator and cirucuit breaker substation service provider

Repair, maintenance, and installation of plant/ systems/equipments (version 2) - construction work of 01 number 33kv feeder bay for simrau including installing of capacitor bank isolator and cirucuit breaker substation service provider

Read more
Bifurcation of the existing 11kv dnm colony feeder emanating from 33/11kv lodha indoor ss by using existing idle 11kv capacitor bank breaker and laying of 0.5 km 11kv 3x300 sqmm xlpe ug cable (double run) in sanathnagar section of sanathnagar subdivision in greenlands division and the work will be executed by the construction wing of banjara hills circle

Bifurcation of the existing 11kv dnm colony feeder emanating from 33/11kv lodha indoor ss by using existing idle 11kv capacitor bank breaker and laying of 0.5 km 11kv 3x300 sqmm xlpe ug cable (double run) in sanathnagar section of sanathnagar subdivision in greenlands division and the work will be executed by the construction wing of banjara hills circle

Read more
Construction of 220/132kv, 160mva and 132/33kv, 31.5mva substation at palana (distt.-bikaner) along with associated 01 no. of 132 kv bay at 132 kv gss shisha with 01 no. of 33 kv, 5.43 mvar capacitor bank turnkey basis bn9019002602

Construction of 220/132kv, 160mva and 132/33kv, 31.5mva substation at palana (distt.-bikaner) along with associated 01 no. of 132 kv bay at 132 kv gss shisha with 01 no. of 33 kv, 5.43 mvar capacitor bank turnkey basis bn9019002602

Read more
3 kvar metalized polypropylene gas filled, wavy cut three phase self-healing type capacitors, rated at 480v, 50hz, rated current 3.6 amps. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-1)/latest and confirming to is: 13340 (part-1): 2012 / iec 60831-1:2002/latest with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: m/s epcos or m/s vishay or any other equivalent capacitor confirm

3 kvar metalized polypropylene gas filled, wavy cut three phase self-healing type capacitors, rated at 480v, 50hz, rated current 3.6 amps. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-1)/latest and confirming to is: 13340 (part-1): 2012 / iec 60831-1:2002/latest with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: m/s epcos or m/s vishay or any other equivalent capacitor confirm

Read more
3 kvar metalized polypropylene gas filled, wavy cut three phase self healing type capacitors, rated at 480v, 50hz , rated current 3.6 amps. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-1)/latest and confirming to is: 13340 (part-1) : 2012 / iec 60831-1:2002/latest with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: m/s epcos or m/s vishay or any other equivalent capacitor confir

3 kvar metalized polypropylene gas filled, wavy cut three phase self healing type capacitors, rated at 480v, 50hz , rated current 3.6 amps. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-1)/latest and confirming to is: 13340 (part-1) : 2012 / iec 60831-1:2002/latest with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: m/s epcos or m/s vishay or any other equivalent capacitor confir

Read more
Miscellaneous electrical job at 33kv nlocp substation under cv area-xii, bccl

Miscellaneous electrical job at 33kv nlocp substation under cv area-xii, bccl

Read more
Miscellaneous electrical job at 33kv nlocp substation under cv area-xii, bccl

Miscellaneous electrical job at 33kv nlocp substation under cv area-xii, bccl

Read more
A) ovh. and rep. of a/crt. for 6nos. f/i switch 3nos. rly panel of 33kv mocb/vcb at nlocp at 33kv nlocp s/s under cv area-xii. bccl. (b) rep. of 11kv, 400amps c/g make o/crt breaker a at 33kv nlocp s/s. cv area-xii, bccl.

A) ovh. and rep. of a/crt. for 6nos. f/i switch 3nos. rly panel of 33kv mocb/vcb at nlocp at 33kv nlocp s/s under cv area-xii. bccl. (b) rep. of 11kv, 400amps c/g make o/crt breaker a at 33kv nlocp s/s. cv area-xii, bccl.

Read more