Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Providing Of 2nd Alternate Source To 33/11k V Kundanbagh Indoor Ss By Laying Of 1.2 Km 33k V 3 X400 Sq.Mm. Xlpe Ug Cable (Double Run) From 33/11k V Green Lands Ss To 33/11k V Kundanbagh Indoor Ss Pertaining To Allwyn Lines Section And Sub Division Of Banjara Hills Lines Division Of Scada Circle And Work Executed By The Master Plan Sd Iv Section And Sub Division Of Mp 1 Division Of Master Plan Hyderabad Circle Under T And D Improvements To Original Works (Reserved For Sc Categ
|
| Description |
Providing Of 2nd Alternate Source To 33/11k V Kundanbagh Indoor Ss By Laying Of 1.2 Km 33k V 3 X400 Sq.Mm. Xlpe Ug Cable (Double Run) From 33/11k V Green Lands Ss To 33/11k V Kundanbagh Indoor Ss Pertaining To Allwyn Lines Section And Sub Division Of Banjara Hills Lines Division Of Scada Circle And Work Executed By The Master Plan Sd Iv Section And Sub Division Of Mp 1 Division Of Master Plan Hyderabad Circle Under T And D Improvements To Original Works (Reserved For Sc Category).
|
| Organisation | SOUTHERN POWER DISTRIBUTION COMPANY OF TELANGANA L-CGM-Master Plan&Lines |
| Tender Id | 737172 |
|
Reference Number |
BID No. Chief Engineer/Master Plan /GH/TGSPDCL:27 /2026-27 |
| Tender Fee | - |
| EMD | - |
| Tender Value | 50.61 Lakh |
| Place | Telangana |
| Link |
View Original Tender Notice
https://tender.telangana.gov.in/TenderDetailsHome.html |
| Start Date | September 26, 2026 21:30 |
| End Date |
Expired
12/10/2026
Expired 2 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
110kvugcablefrom proposed gangaikondansipcot230/110kv ss toproposedgangaikondan sipcot110/33-11kv ss
110kvugcablefrom proposed gangaikondansipcot230/110kv ss toproposedgangaikondan sipcot110/33-11kv ss
Read moreM.266/2026-27 - procurement of 110v dc indoor control and relay panel for twin feeder breaker for 33/11kv ss
Procurement of 110v dc indoor control and relay panel for twin feeder breaker for 33/11kv ss.
Read moreBifurcation of 11kv lucid feeder originally emanating from 33/11kv command control room substation by erection of 1 no new 11kv feeder from the 33/11kv road no.2 ss by utilization of 11kv indoor breaker in the 33/11kv road no.2 ss which includes laying of 0.6 km of 11kv 3x300 sq.mm of xlpe ug cable(double run) in banjara hills section of banjara hills subdivision of banjarahills division and the work executed by the construction wing of banjara hills division of banjara hills circle
Bifurcation of 11kv lucid feeder originally emanating from 33/11kv command control room substation by erection of 1 no new 11kv feeder from the 33/11kv road no.2 ss by utilization of 11kv indoor breaker in the 33/11kv road no.2 ss which includes laying of 0.6 km of 11kv 3x300 sq.mm of xlpe ug cable(double run) in banjara hills section of banjara hills subdivision of banjarahills division and the work executed by the construction wing of banjara hills division of banjara hills circle
Read moreReplacement of old 11 kv indoor vcb panels with new 11kv indoor vcb panels at dasda 33/11kv sub-station under electrical sub-division, dasda under the jurisdiction of ed-kanchanpur tsecl
Replacement of old 11 kv indoor vcb panels with new 11kv indoor vcb panels at dasda 33/11kv sub-station under electrical sub-division, dasda under the jurisdiction of ed-kanchanpur tsecl
Read moreRepacing the damaged rcc cover slab of the existing cable duct at 33 kv indoor ss sriperumbudur
Repacing the damaged rcc cover slab of the existing cable duct at 33 kv indoor ss sriperumbudur
Read moreProviding of 2nd run ug cable for the existing 33kv industrial area feeder from 132/33kv fever hospital eht sub station to 33/11kv industrial area ss which involves laying of 1.87km of 33kv 3x400sq.mm xlpe ug cable (single run) in lines division of hyderabad south and the work executed by the master plan sd-ii of division-ii in master plan hyderabad circle under t and d improvements to original works (reserved for waddera/sagara category).
Providing of 2nd run ug cable for the existing 33kv industrial area feeder from 132/33kv fever hospital eht sub station to 33/11kv industrial area ss which involves laying of 1.87km of 33kv 3x400sq.mm xlpe ug cable (single run) in lines division of hyderabad south and the work executed by the master plan sd-ii of division-ii in master plan hyderabad circle under t and d improvements to original works (reserved for waddera/sagara category).
Read moreBifurcation of 11kv old bowenpally feeder emanating from 33/11 kv chinna thokatta ss by erection of new 11kv feeder from 33/11kv old bowenpally ss which involves laying of 3.9 km 3x300 sq.mm. 11kv xlpe ug cable (single run) along with erection of 1no. 11 kv feeder vcb at 33/11kv old bowenpally ss in old bowenpally section of bowenpally sub-division of bowenpally division in secunderabad circle under t and d improvements to original works under waddera/ sagara reserved category
Bifurcation of 11kv old bowenpally feeder emanating from 33/11 kv chinna thokatta ss by erection of new 11kv feeder from 33/11kv old bowenpally ss which involves laying of 3.9 km 3x300 sq.mm. 11kv xlpe ug cable (single run) along with erection of 1no. 11 kv feeder vcb at 33/11kv old bowenpally ss in old bowenpally section of bowenpally sub-division of bowenpally division in secunderabad circle under t and d improvements to original works under waddera/ sagara reserved category
Read moreBifurcation of 11kv central excise feeder emanating from 33/11 kv chinna thokatta ss by erection of 2.8km new 11kv feeder from 33/11 kv old bowenpally ss which involves laying of 2.8km 3x300 sq.mm. 11kv xlpe ug cable (single run) along with erection of 1no. 11kv feeder vcb at 33/11kv old bowenpally ss in old bowenpally section of bowenpally sub-division of bowenpally division in secunderabad circle under t and d improvements to original works under general category
Bifurcation of 11kv central excise feeder emanating from 33/11 kv chinna thokatta ss by erection of 2.8km new 11kv feeder from 33/11 kv old bowenpally ss which involves laying of 2.8km 3x300 sq.mm. 11kv xlpe ug cable (single run) along with erection of 1no. 11kv feeder vcb at 33/11kv old bowenpally ss in old bowenpally section of bowenpally sub-division of bowenpally division in secunderabad circle under t and d improvements to original works under general category
Read moreBifurcation of the existing 11kv dnm colony feeder emanating from 33/11kv lodha indoor ss by using existing idle 11kv capacitor bank breaker and laying of 0.5 km 11kv 3x300 sqmm xlpe ug cable (double run) in sanathnagar section of sanathnagar subdivision in greenlands division and the work will be executed by the construction wing of banjara hills circle
Bifurcation of the existing 11kv dnm colony feeder emanating from 33/11kv lodha indoor ss by using existing idle 11kv capacitor bank breaker and laying of 0.5 km 11kv 3x300 sqmm xlpe ug cable (double run) in sanathnagar section of sanathnagar subdivision in greenlands division and the work will be executed by the construction wing of banjara hills circle
Read moreErection of 33/11 kv indoor ss with 1x16 mva ptr and connected 33kv feeders - 2 nos. 11kv feeders with 4 nos. and construction of control room, compound wall at sagar x road ss at bairamalguda section of vanastalipuram subdivision in champapet division of saroornagar circle in ecgh master plan division in rangareddy circle under t and d improvement works
Erection of 33/11 kv indoor ss with 1x16 mva ptr and connected 33kv feeders - 2 nos. 11kv feeders with 4 nos. and construction of control room, compound wall at sagar x road ss at bairamalguda section of vanastalipuram subdivision in champapet division of saroornagar circle in ecgh master plan division in rangareddy circle under t and d improvement works
Read moreof your Industry type