Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
10 Kva Igbt Based Under Slung Inverter Input 110 V Dc Output 230 V Ac Etc.
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106391270 |
|
Reference Number |
AD241640 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Kolkata |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/072024/106391270/viewNitPdf_4622692.pdf |
| Start Date | June 28, 2024 00:01 |
| End Date |
Expired
01/07/2024
Expired 837 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
10 kva igbt based under slung inverter input 110v dc etc.
10 kva igbt based under slung inverter input 110v dc etc.
Read moreDc power supply source input 230 v ac, 50 hz, output 24 vdc, 68 vdc and 72 vdc, 10 amp, on/off switch and fuse with over voltage, overload and short circuit protection.
Dc power supply source input 230 v ac, 50 hz, output 24 vdc, 68 vdc and 72 vdc, 10 amp, on/off switch and fuse with over voltage, overload and short circuit protection.
Read moreProgrammable current transducer, input: 0-1aac, range: 0-1aac, output: 4-20 ma dc (dual output) , accu,multifunction meter for metering panels (with rs485modbus) , input: on site programmable-voltage - 10
Programmable current transducer, input: 0-1aac, range: 0-1aac, output: 4-20 ma dc (dual output) , accu,multifunction meter for metering panels (with rs485modbus) , input: on site programmable-voltage - 10
Read more24v starter battery charger for 500 kva dg set of eog power car conforming to rcf spec. no. edts - 106 (rev-0) am-1,2 & corr-1 / latest input voltage: 230 +/- 5 volts ac, output voltage: 27 volts dc, current rating: 50amps.
24v starter battery charger for 500 kva dg set of eog power car conforming to rcf spec. no. edts - 106 (rev-0) am-1,2 & corr-1 / latest input voltage: 230 +/- 5 volts ac, output voltage: 27 volts dc, current rating: 50amps.
Read moreDriver 18 watt for 4 feet light fitting for 3 phase rakes suitable for ensave led light fitting as per rdso spec. no. rdso/pe/spec/tl/0091-2016 (rrv-1). (input voltage- 110v ac/dc,output voltage-24v dc)
Driver 18 watt for 4 feet light fitting for 3 phase rakes suitable for ensave led light fitting as per rdso spec. no. rdso/pe/spec/tl/0091-2016 (rrv-1). (input voltage- 110v ac/dc,output voltage-24v dc)
Read moreSupply and installation of 230 v ac /48 v 25 ams dc (2+1 configuration) smps battery charger.
Supply and installation of 230 v ac /48 v 25 ams dc (2+1 configuration) smps battery charger.
Read moreCurrent transducer input 0 to 5a,frequency transducer range 45 50 55,ac volt transducer 0 to 150v sn0659395452,ac volt transducer 0 to500kv sn0659395410,active p transducer 0 to 600mw sn0659395444,dc v transducer tra 430 input volt 0 10v dc,pf transducer 0.5lg-1-0.5ld sn0659395401,reactive p transducer190.52le-0-190.52la,reactive pwr transducer mvar 600 9 600,volt to current tran sducer input 0 to 60mv,current transducer,dual output 0 to 1a ac,8066 ac trnsdr 0 to 5a 4 to 20ma sn06593,cur tran input 0 to 1a output 4 to 20ma aux 220vdc,cur transdcr davr u55 1ph 2w input 110vac,volt transr input 0 to 50vdc aux 24vdc 2 output,mw tran model 8075 output 4 to 20ma rang 0 to 190,w tran aux 220vdc output 4 to 20 ma ct 3000 1,mw transr 0 to 1.797mw ctr2500 1 pt415 110v,voltage transducer dual output 0 5kv ac,v tran aux 240vac output 4 to 20 ma 0 to 25kv,3phase power factor trnd 8091 0.5le 1 0.5la,power transducer dual output 0 to 16mw,power transducer dual output 0 to 25 mw
Current transducer input 0 to 5a,frequency transducer range 45 50 55,ac volt transducer 0 to 150v sn0659395452,ac volt transducer 0 to500kv sn0659395410,active p transducer 0 to 600mw sn0659395444,dc v transducer tra 430 input volt 0 10v dc,pf transducer 0.5lg-1-0.5ld sn0659395401,reactive p transducer190.52le-0-190.52la,reactive pwr transducer mvar 600 9 600,volt to current tran sducer input 0 to 60mv,current transducer,dual output 0 to 1a ac,8066 ac trnsdr 0 to 5a 4 to 20ma sn06593,cur tran input 0 to 1a output 4 to 20ma aux 220vdc,cur transdcr davr u55 1ph 2w input 110vac,volt transr input 0 to 50vdc aux 24vdc 2 output,mw tran model 8075 output 4 to 20ma rang 0 to 190,w tran aux 220vdc output 4 to 20 ma ct 3000 1,mw transr 0 to 1.797mw ctr2500 1 pt415 110v,voltage transducer dual output 0 5kv ac,v tran aux 240vac output 4 to 20 ma 0 to 25kv,3phase power factor trnd 8091 0.5le 1 0.5la,power transducer dual output 0 to 16mw,power transducer dual output 0 to 25 mw
Read moreSplit type room air conditioner technology inverter (variable speed )normal cooling capacity 2.0 ton (6000kcal/hr)bee star rating 5 star input power efficient to work on single phase 230 volt 50hz +/- 10 percent power supply
Split type room air conditioner technology inverter (variable speed )normal cooling capacity 2.0 ton (6000kcal/hr)bee star rating 5 star input power efficient to work on single phase 230 volt 50hz +/- 10 percent power supply
Read moreElectro pneumatics regulator model no. -itv3050-344s3, input dc 0-10v, output 0.05-8 bar, voltage dc2,3 port solenoid valve actuator, model no. -vp742-5dz1-04a-f, pressure 0.2-0.7 mpa, voltage 24vdc, pow
Electro pneumatics regulator model no. -itv3050-344s3, input dc 0-10v, output 0.05-8 bar, voltage dc2,3 port solenoid valve actuator, model no. -vp742-5dz1-04a-f, pressure 0.2-0.7 mpa, voltage 24vdc, pow
Read moreof your Industry type