Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Repairing Of Vcb Switch Of Make Meditron Pvt Ltd, 400 A, 11 Kv/6.6 Kv Sl. No. 9319 Of Main Substation And Repairing Of Vcb Switch Of Make Meditron Pvt Ltd, 400 A, 11 Kv/6.6 Kv Sl. No. 9317 Of Main Substation Of Nakc Under Govindpur Area
|
| Description |
Repairing Of Vcb Switch Of Make Meditron Pvt Ltd, 400 A, 11 Kv/6.6 Kv Sl. No. 9319 Of Main Substation And Repairing Of Vcb Switch Of Make Meditron Pvt Ltd, 400 A, 11 Kv/6.6 Kv Sl. No. 9317 Of Main Substation Of Nakc Under Govindpur Area
|
| Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
| Tender Id | 2025_BCCL_330510_1 |
|
Reference Number |
BCCL/GA-III/AM (EnM) E-TENDER/2024-25/234 |
| Tender Fee | 0 |
| EMD | 2311 |
| Tender Value | - |
| Place | Govindpur Area Office |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=342590 |
| Start Date | March 04, 2025 16:30 |
| End Date |
Expired
10/03/2025
Expired 585 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
For repairing of incomer 400a,6.6kv, ocb switch sl.no. bsp/switch/06 make ferguson at ekra substation basdeopur colliery under sijua area
For repairing of incomer 400a,6.6kv, ocb switch sl.no. bsp/switch/06 make ferguson at ekra substation basdeopur colliery under sijua area
Read moreMaintenance and reconditioning of 2 nos. vcb (11kv and 6.6kv, pce make), 2 nos. ocb switch (11kv, 800 amp, gec make), sf6 abb make breaker (33kv, 1250 amp), maintenance of ct, and repairing of 11kv capacitor bank control panel at central substation
Maintenance and reconditioning of 2 nos. vcb (11kv and 6.6kv, pce make), 2 nos. ocb switch (11kv, 800 amp, gec make), sf6 abb make breaker (33kv, 1250 amp), maintenance of ct, and repairing of 11kv capacitor bank control panel at central substation
Read more11kv switchboards for water works substation 9vcb,installation, testing , commissioning of 11kv switchboards for water works substation 09 vcb,11kv switchboards for sector4 substation,installation, testing , commissioning of 11kv switchboards for sector4 substation,11kv switchboards for sector7 substation,nstallation, testing , commissioning of 11kv switchboards for sector7 substation.,11kv switchboards for adbuilding substation,installation, testing , commissioning of 11kv switchboards for adbuilding substation,11kv switchboards for workshop area substation,installation, testing , commissioning of 11kv switchboards for workshop area substation,11kv switchboards for lab area substation,installation, testing , commissioning of 11kv switchboards for lab area substation
11kv switchboards for water works substation 9vcb,installation, testing , commissioning of 11kv switchboards for water works substation 09 vcb,11kv switchboards for sector4 substation,installation, testing , commissioning of 11kv switchboards for sector4 substation,11kv switchboards for sector7 substation,nstallation, testing , commissioning of 11kv switchboards for sector7 substation.,11kv switchboards for adbuilding substation,installation, testing , commissioning of 11kv switchboards for adbuilding substation,11kv switchboards for workshop area substation,installation, testing , commissioning of 11kv switchboards for workshop area substation,11kv switchboards for lab area substation,installation, testing , commissioning of 11kv switchboards for lab area substation
Read moreRepairing overhauling of 400amps vcb switch 6.6kv make - gec si.no. 455357 3 at kantapahari sub station akwmc , under katras area.
Repairing overhauling of 400amps vcb switch 6.6kv make - gec si.no. 455357 3 at kantapahari sub station akwmc , under katras area.
Read morePreventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Preventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Read moreRepairing of 750 kva, 11kv 6.6kv 440v, lighting transformer make kva process transformers p ltd at mpl and 500 kva,11kv 440v,make mandb switchgears ltd transformer at nadkhurkee main substation abocp..
Repairing of 750 kva, 11kv 6.6kv 440v, lighting transformer make kva process transformers p ltd at mpl and 500 kva,11kv 440v,make mandb switchgears ltd transformer at nadkhurkee main substation abocp..
Read moreAnnual rate contract for preventive maintenance and calibration testing of various ht equipment and ht panels (vcb) in 33kv switch yard, 33kv substation and ht lt room at serpl sambalpur for a period of 2 years
Annual rate contract for preventive maintenance and calibration and testing of various ht equipment and ht panels (vcb) in 33kv switch yard, 33kv substation and ht lt room at serpl sambalpur for a period of 2 years
Read moreAnnual maintenance contract (amc) of 01 no substation i/c (integrated circuit) of 11kv ht and lt line and ht metering room contains 11 nos 800 amp 11 kv ht vcb, 6 nos 1600 amp lt acbs and 4 no 1000 amp transformer at gc, crpf jalandhar.
Annual maintenance contract (amc) of 01 no substation i/c (integrated circuit) of 11kv ht and lt line and ht metering room contains 11 nos 800 amp 11 kv ht vcb, 6 nos 1600 amp lt acbs and 4 no 1000 amp transformer at gc, crpf jalandhar.
Read moreHand drill machine 600w 230v 1 point 5 13mm 2800rpm,tester tong 0 to 1000a 660v,3.3kv 400amps fwd off rev isolator part no htsv0003,master trip relay 110v dc cspc86 part no 1907739,puller bearing hyd 10ton,contactor main 550v 300 by 400a,tester hv detector 0 to 11kv for flp switch
Hand drill machine 600w 230v 1 point 5 13mm 2800rpm,tester tong 0 to 1000a 660v,3.3kv 400amps fwd off rev isolator part no htsv0003,master trip relay 110v dc cspc86 part no 1907739,puller bearing hyd 10ton,contactor main 550v 300 by 400a,tester hv detector 0 to 11kv for flp switch
Read moreVcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreof your Industry type