Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Set Of Mpcb Of Different Ratings And Capacities, Suitable For Vb Trainset Coaches As Per Attached Annexure A, Accepted Makes Siemens, Schneider Or Abb Only.
|
| Description |
Set Of Mpcb Of Different Ratings And Capacities, Suitable For Vb Trainset Coaches As Per Attached Annexure A, Accepted Makes Siemens, Schneider Or Abb Only.
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 07, 2026 22:48 |
| End Date |
Open
02/11/2026
16 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Set of mpcb of different rating and capacities, suitable for vande bharat (set of train 18) rake as per attached annexure - a, siemens or schneider or abb make only.
Set of mpcb of different rating and capacities, suitable for vande bharat (set of train 18) rake as per attached annexure - a, siemens or schneider or abb make only.
Read moreMiniature circuit breaker 02 ampere 2 pole 10 ka as per legrand model no. c2 curve dx3 for 3 phase ac locomotives. make-abb, schneider, legrand, eaton, siemens.
Miniature circuit breaker 02 ampere 2 pole 10 ka as per legrand model no. c2 curve dx3 for 3 phase ac locomotives. make-abb, schneider, legrand, eaton, siemens.
Read more1 amp single pole dc mcb with extended terminal, as per rdso drg. no. skel-3700, alt 1 and skel-4034 alt-1 to rdso specification no. spec/e-12/1/04 of 92 with latest amendment for emu/memu motor coaches. makes/brands: indoasian/c&s/havells /legrands/abb/bch/l&t /schneider/siemens/rbco or similar.
1 amp single pole dc mcb with extended terminal, as per rdso drg. no. skel-3700, alt 1 and skel-4034 alt-1 to rdso specification no. spec/e-12/1/04 of 92 with latest amendment for emu/memu motor coaches. makes/brands: indoasian/c&s/havells /legrands/abb/bch/l&t /schneider/siemens/rbco or similar.
Read moreFour pole change over switch disconnector mcb with centre position off(i-o-ii), rated current 40a, operational voltage 415v. makes: legrand / havells / c & s / schneider / abb or its equivalent. note: one sample should be got approved before effecting bulk supply.
Four pole change over switch disconnector mcb with centre position off(i-o-ii), rated current 40a, operational voltage 415v. makes: legrand / havells / c & s / schneider / abb or its equivalent. note: one sample should be got approved before effecting bulk supply.
Read moreMotor protection circuit breaker (mpcb) 6 to 10 amps, 690v ac, 50 hz, 3 pole type gv2p14 of schneider or abb with aux. contact block 2 no (normally open) as per clw specn.no.clw/es/3/0096 alt.l or latest, str no. clw/2021/eldo/e/str/0104 rev.0 or latest.
Motor protection circuit breaker (mpcb) 6 to 10 amps, 690v ac, 50 hz, 3 pole type gv2p14 of schneider or abb with aux. contact block 2 no (normally open) as per clw specn.no.clw/es/3/0096 alt.l or latest, str no. clw/2021/eldo/e/str/0104 rev.0 or latest.
Read more6amps,single pole, dc mcb,130v dc (rated6amps,single pole, dc mcb,130v dc (rated voltage) with extended terminals as per rdso drg. skel-3700, alt 1 and skel 4034, alt 1 and rdso specn.no. spec/e-12/1/04 of march 1992 with amendment 1 of june 1993 (with punching of indian railway emblem & rdso specification). makes/brands: indoasian/ c&s/ havells/ legrands/ abb/ bch/ l&t/ schneider/ siemens/ rbco only. the firm should submit routing test certificate at the time of supply of material.
6amps,single pole, dc mcb,130v dc (rated6amps,single pole, dc mcb,130v dc (rated voltage) with extended terminals as per rdso drg. skel-3700, alt 1 and skel 4034, alt 1 and rdso specn.no. spec/e-12/1/04 of march 1992 with amendment 1 of june 1993 (with punching of indian railway emblem & rdso specification). makes/brands: indoasian/ c&s/ havells/ legrands/ abb/ bch/ l&t/ schneider/ siemens/ rbco only. the firm should submit routing test certificate at the time of supply of material.
Read moreMpcb, current rating : 3-4 a, thermal release range: 2.5 - 4 .0 a, class: 10, breaking capacity: 50ka, pole: 3 p, voltage: 415 v ac, 1no+1nc auxiliary contact block. make: legrand (002807 = 002817), abb (ms116-4), hk1-11), schneider (gv2me08 = gvan11), l&t (st418960000 + sr419450000), siemens (3vu1340 - 0mj00 1no = 1nc:3rv1901-1a or 3vu9131-3aa00), c&s (tcms-32s-4 + tfx11), eaton (pkzm0-4 + nhi-11-pkz0) as per bill of material (bom) of rdsos specn. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as p
Mpcb, current rating : 3-4 a, thermal release range: 2.5 - 4 .0 a, class: 10, breaking capacity: 50ka, pole: 3 p, voltage: 415 v ac, 1no+1nc auxiliary contact block. make: legrand (002807 = 002817), abb (ms116-4), hk1-11), schneider (gv2me08 = gvan11), l&t (st418960000 + sr419450000), siemens (3vu1340 - 0mj00 1no = 1nc:3rv1901-1a or 3vu9131-3aa00), c&s (tcms-32s-4 + tfx11), eaton (pkzm0-4 + nhi-11-pkz0) as per bill of material (bom) of rdsos specn. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as p
Read moreFeeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de
Feeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de
Read moreVentilation fan motor of 5.0-5.5 kw/6.7-7.5 hp rating, 415v ac, 3-phase, 50hz, ip-65, insulation class-h, min 1440 rpm, roof mounted, as per rdso specification no. rdso/pe/spec/ac/0084-2008 (rev.1). suitable for use in lhb-type power cars. accepted make: m/s abb, m/s laxmi hydraulic, m/s crompton, m/s siemens, m/s kirloskar electric, or any other rdso-approved make.
Ventilation fan motor of 5.0-5.5 kw/6.7-7.5 hp rating, 415v ac, 3-phase, 50hz, ip-65, insulation class-h, min 1440 rpm, roof mounted, as per rdso specification no. rdso/pe/spec/ac/0084-2008 (rev.1). suitable for use in lhb-type power cars. accepted make: m/s abb, m/s laxmi hydraulic, m/s crompton, m/s siemens, m/s kirloskar electric, or any other rdso-approved make.
Read moreResidual current circuit breaker with overload (rcbo) 16a, 4 pole with type d tripping curves. 415v,50hz, sensibility 30ma ac. breaking capacity 6-10 ka, suitable to fit with din rail clamps. impulse current withstands at 8/20 microseconds pulses = 3ka, make: legrand (or) schneider (or) abb (or) lk (or) siemens only. similar to cat no. auf3d401603, part no : a9n4p16d, a9v61440. the material shall be procured from the said oem or their authorized dealers with tender specific authorization onl
Residual current circuit breaker with overload (rcbo) 16a, 4 pole with type d tripping curves. 415v,50hz, sensibility 30ma ac. breaking capacity 6-10 ka, suitable to fit with din rail clamps. impulse current withstands at 8/20 microseconds pulses = 3ka, make: legrand (or) schneider (or) abb (or) lk (or) siemens only. similar to cat no. auf3d401603, part no : a9n4p16d, a9v61440. the material shall be procured from the said oem or their authorized dealers with tender specific authorization onl
Read moreof your Industry type