Tender Details

Particulars Details
Title
Repairing Of A.B. Switch Of 11 Kv/440 V,11 Kv/3.3 Kv And 3.3 Kv O/H Line In Albion Sub Station And Changing Of Damaged Guard Wire And Earth Wire For Smooth And Safe Power Supply At Damoda Colliery
Description
Repairing Of A.B. Switch Of 11 Kv/440 V,11 Kv/3.3 Kv And 3.3 Kv O/H Line In Albion Sub Station And Changing Of &#X0d Damaged Guard Wire And Earth Wire For Smooth And Safe Power Supply At Damoda Colliery
Organisation Bharat Coking Coal Limited | Public Sector Undertakings
Tender Id 2024_BCCL_313104_1
Reference
Number
BCCL/GM/AR-I/AM (ENM)/E-TENDER/2024-25/161
Tender Fee 0
EMD 1700
Tender Value
Place DAMODA COLLIERY BARORA AREA
Link https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=324468
Start Date July 23, 2024 00:00
End Date

02/08/2024 ( Expired 330 days ago )

Search Similar tenders?
Join for More
Relevant Opportunities
Similar Tenders
Construction of 33 kv line and 33/11 kv, 2.5 mva sub-station including terminal equipments and control room for providing power supply to indian agricultural research institute under ghilamara electrical sub-division of north lakhimpur electrical c

Construction of 33 kv line and 33/11 kv, 2.5 mva sub-station including terminal &amp#x0d equipments and control room for providing power supply to indian agricultural research &amp#x0d institute under ghilamara electrical sub-division of north lakhimpur ec

Read more
New supply, installation n commissioning of ug flp lighting arrangement for pump station, switch station, sub-station and travelling road way of 8d n 30l development district at bansra colliery under kunustoria area

New supply, installation n commissioning of ug flp lighting arrangement for pump station, switch station, sub-station and travelling road way of 8d n 30l development district at bansra colliery under kunustoria area

Read more
Maintenance of 3.3kv oh line from dumerbera sub-station to 16b quarry and installation of 400a rated goab and do fuse at 16b quarry for safe operation 250kva 3.3kv/440v transformer installated at 16b quarry of ara colliery under kuju

Maintenance of 3.3kv oh line from dumerbera sub-station to 16b quarry and installation of 400a rated goab and do fuse at 16b quarry for safe operation 250kva 3.3kv/440v transformer installated at 16b quarry of ara colliery under kuju

Read more
Extension of 6.6kv and 3.3kv o/h line for h.t pump and 578 no. shovel at nocp(ii)erection of 4 pole span 6.6kv o/h for pumping operation and 4 pole span 440v o/h near b type

Extension of 6.6kv and 3.3kv o/h line for h.t pump and 578 no. shovel at nocp(ii)erection of 4 pole span 6.6kv o/h for pumping operation and 4 pole span 440v o/h near b type

Read more
Repairing and fixing of wti and oit and buchholz relay along with painting of one (01) no. 11kv/3.3kv, 3mva and one no. 11kv/3.3kv, 2.5 mva transformer at 02 no. sub-station considering dgms guideline and safety of the equipment under katahra collier

Repairing and fixing of wti and oit and buchholz relay along with painting of one (01) no. 11kv/3.3kv, 3mva and one no. 11kv/3.3kv, 2.5 mva transformer at 02 no. sub-station considering dgms guideline and safety of the equipment under katahra collier

Read more
Complete repairing of 3.3kv/400amps gec make ht ocb switch for controlling 3.3kv overhead line block-iv ocp at sub-station kali mandir of abgc under govindpur area-iii si.no 5513

Complete repairing of 3.3kv/400amps gec make ht ocb switch for controlling 3.3kv overhead line block-iv ocp at sub-station kali mandir of abgc under govindpur area-iii si.no 5513

Read more
Repairing and maintenance of 440v o/h line in badhi basti under govindpur area

Repairing and maintenance of 440v o/h line in badhi basti under govindpur area

Read more
Dismantling and re-erection of section of 440v, 3 phase 4 wire o/h distribution line at premnagar colony and sinidih officer colony under bilbera switch station, govindpur area

Dismantling and re-erection of section of 440v, 3 phase 4 wire o/h distribution line at premnagar colony and sinidih officer colony under bilbera switch station, govindpur area

Read more
For di of 11kv o/h line from tocp substn (including upgradation from 6.6kv o/h line) to mallah dhawrah at tetulmari colliery (ii)and strengthening of 02 span of 6.6kv 59 feeder,fitting of a.b switch for two side power supply(58 and 59 feeder

For di of 11kv o/h line from tocp substn (including upgradation from 6.6kv o/h line) to mallah dhawrah at tetulmari colliery (ii)and strengthening of 02 span of 6.6kv 59 feeder,fitting of a.b switch for two side power supply(58 and 59 fedr

Read more
Repairing of pipe line used for supply of water from 6 pit bararee to 1 no. colony and bazar dhowra under bararee section total section of pipeline to be repaired damaged and worn out pipe is 120 mrt 4 inch dia m.s. pipe and changing/replace 4 in

Repairing of pipe line used for supply of water from 6 pit bararee to 1 no. colony and bazar dhowra under bararee section total section of pipeline to be repaired damaged and worn out pipe is 120 mrt 4 inch dia m.s. pipe and changing/replace 4 in

Read more