Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
T,E And C Of Existing 6.6 Kv, 300 Hp, Bha700 H Pump Sets, 600 Hp Submersible Pump Sets Near Puttamgandi Including Mo M Of Pumping Station Of 4 Months And Dismantling And Transportation Of All Equipmentto Kpur, Gkondla And Under Td Iii, Sahebnagar
|
| Description |
Transportation, Erection, Testing And Commissioning Of Existing 6.6 Kv, 300 Hp, Bha 700 H Pump Sets, 600 Hp Submersible Pump Sets And All Allied Works And Formation Of Bund Across The Approach Main Canal To Maintain Required Level In Canal For Emergency Pumping Arrangements At Foreshore Of Nagarjunasagar Near Puttamgandi Including Mo M Of Pumping Station For 4 Months And Dismantling And Transportation Of All Equipment To Kodandapur, Nasarlapally And Godakondla Whenever Sufficient Inflows Ed At Nagarjunasagar Reservoir Under Eam Section, Sd Iv(electrical), Transmission Div.Iii, Sahebnagar
|
| Organisation | Information Technology Electronics and Communication Department Telangana | State Govt. and UT |
| Tender Id | 581395 |
|
Reference Number |
EP.No.100/CGM(E)/TC/T3/Puttamgandi/TD-III/2024-25 dt:13.03.2025 |
| Tender Fee | 5276 |
| EMD | 1.49 Lakh |
| Tender Value | - |
| Place | TS |
| Link |
View Original Tender Notice
http://eprocurement.telangana.gov.in/ |
| Start Date | March 13, 2025 22:30 |
| End Date |
Expired
20/03/2025
Expired 570 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
T e and c of existing 6.6kv, 300 hp bha 700h pumpsets 600 hp submersible pump sets near puttamgandi including mom of pumping station for 4 months and dismantling and transportation of all equipment under td-iii, sahebnagar
Transportation, erection, testing and commissioning of existing 6.6kv, 300hp, bha 700h pump sets, 600hp submersible pump sets and all allied works and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi including mom of pumping station for 4 months and dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed at nagarjunasagar reservoir under eam section, sd-iv(electrical), transmission div.iii, sahebnagar
Read moreAnnual maintenance of 132/6.6kv substations having 12 nos of 12/16 mva power transformers and 6.6kv phae-i, ii and iii pumping stations having 108 nos of 6.6kv 1425, 1475 and 1300kw hsc pumpsets along with allied equipment at kpur, npally, gkondla and other stations along with allied equipment at kpur, npally and gkondla and other stations for the period of two years sd-i, td-iii, sahebnagar
Annual maintenance of 132/6.6kv substations having 12nos of 12/16 mva power transformers and 6.6kv phase-i, ii and iii pumping stations having 108 nos of 6.6kv 1425,1475 and 1300kw hsc pumpsets along with allied equipment at kodandapur, nasarlapally, godakondla and other stations for the period of (two) 02 years sd-i, td-iii, sahebngar.
Read moreTet nd c 33 6.6kv electrical substation including existing 4 no of 3150 kva power transformer to feed the power supply to emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi under td-iii, sahebnagar
Transportation, erection, testing and commissioning of 33 6.6 kv electrical substation including existing 4 no of 3150kva power transformers, electrical panels, cables, 33kv over head line and all allied electrical equipement to feed the power supply to emergency pumping arrangements at foreshore of nagarjuna sagar near puttamgandi including 4 months mom for substation,dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir, under eam section, electrical sub division,transmission div.iii, sahebnagar
Read moreT,e,t comm of 33/6.6kv electrical substation including existing 4 nos of 3150kva power transformers, electrical panels, cabels, 33kv overhead line and all allied equipment to feed the power supply to emergency pumping arrangements at foreshore of nagarjuna sagar near puttamgandi including 4 months mom for substation, dismantling and transportation of all equipment to kpur, npally and gkondla whenever sufficient inflows ed to nagarjunasagar reservoir under eam section, om div.xi, saheb
Transportation, erection, testing and commissioning of 33/6.6 kv electrical substation including existing 4 no of 3150kva power transformers, electrical panels, cables, 33kv over head line and all allied electrical equipement to feed the power supply to emergency pumping arrangements at foreshore of nagarjuna sagar near puttamgandi including 4 months mom for substation, dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir, under eam section, electrical sub division,transmission div.iii, sahebnagar
Read moreMom of 6.6kv pumping station having 6 nos of 6.6kv, 850kw, hsc pumpsets along with allied equipment at ph-iv peddapur for a period of one year under td-
Manning, operation and maintenance of 6.6 kv pumping station having 6 nos of 6.6 kv, 850 kw, hsc pump sets along with allied equipment at phase-iv, pump house, peddapur for the period of one year, under eam cell-ii, peddapur,transmission division-ii, patancheru.
Read moreR t comm of 33 6.6kv 2500kva ptr sdit comm of motor ers providing of gabions and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi under td-iii, sahebnagar
Rewinding, testing commissioning of 33 6.6kv, 2500kva ptr ,supply, delivery, installation, testing commissioning of motor ers, air-circuit breaker, repairing of pumps and motors, providing of gabions and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi and also dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir under eam section, sub division-iv, transmission div no.iii, sahebnagar
Read moreRefurbishment of existing 2000amps 6.6kv, vcb panels including supply, delivery,erection, testing and commissioning of 6.6kv ht vcb panels at ph-i of 132/6.6kv sub-statios bearing housing and vcbs for 1425kw, 1475kw and 1300kw pump sets at kodandapur, nasarlapally and godakondla under eam section, electrical sub division,td-iii, sahebnagar
Refurbishment of existing 2000 amps 6.6 kv, vcb panel including supply, delivery, erection, testing and commissioning of 6.6kv ht vcb panels at phase-i of 132 6.6kv substations, bearing housing and vcbs for 1425kw, 1475 kw and 1300 kw pump sets at kodandapur, nasarlapally and godakondla under eam section electrical sub division, transmission division no.iii, sahebnagar.
Read moreAnnual maintenance of 2200mm dia/2375mm dia ms pumping main 76kms and gravity main of 36kms kodandapur to sahebnagar 9ml and 9ml clear water reservoirs of ph-i 18ml clear water reservoirs of phase-ii and phase-iii in the premises at kpur, npally and gkondla and 6 nos of 22.50 ml mbr of kdwso ph-i,ii iii in the premises at gungal under sd.i, td-iii, sahebnagar for a period of two years
Annual maintenance of 2200/2375 mm dia ms pumping main 76kms and gravity main of 38 kms from kodandapur to sahebnagar, 9ml and 9ml clear water reservoirs of phase-i, 18ml clear water reservoirs of phase-ii and phase-iii in the premises at kodandapur , nasarlapally and godakondla and 6 nos of 22.50ml master balancing reservoirs of kdwsp phase-i,ii and iii in the premises at gungal,sd-i, td-iii, sahebngar for the period of (two) 02 years
Read moreR,t comm of 33 6.6kv, 2500kva ptr sdit and comm of motor ers providing of gabions and formation of bund across main canal to maintain required level in canal for emergency pumping arrangement at foreshore of nagarjunasagar near puttamgandi and also dismantling and transportation of all equipment under td-iii, sahebnagar
Rewinding, testing commissioning of 33 6.6kv, 2500kva ptr ,supply, delivery, installation, testing commissioning of motor ers, air-circuit breaker, repairing of pumps and motors, providing of gabions and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi and also dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir under eam section, sub division-iv, transmission div no.iii, sahebnagar
Read moreAnnual maintenance of 2200/2375mm dia ms pumping main 76kms and gravity main of 38 kms from kodandapur to sahebnagar 9ml and 9ml clear water reservoirs of ph-i 18 ml clear water reservoirs of ph-ii and ph-iii in the premises at kpur, npally and gkondla and 6 nos of 22.50 ml master balancing reservoirs of kdwsp ph-i, ii and iii in the premises of gungal, sd-i, td-iii, sahebnagar for the period of (02) two years
Annual maintenance of 2200/2375 mm dia ms pumping main 76kms and gravity main of 38 kms from kodandapur to sahebnagar, 9ml and 9ml clear water reservoirs of phase-i, 18ml clear water reservoirs of phase-ii and phase-iii in the premises at kodandapur , nasarlapally and godakondla and 6 nos of 22.50ml master balancing reservoirs of kdwsp phase-i,ii and iii in the premises at gungal,sd-i, td-iii, sahebngar for the period of (two) 02 years
Read moreof your Industry type