Tender Details
Particulars | Details |
---|---|
Title |
Ttps Operation Circle Mpm Ii Acp Reconditioning Of Cooling Tower C By Replacing Of Fills, Drift Eliminators, Spray Header Pipes, Overhauling Of 200 Nb 150 Nb Gate Valves, Eroded Discharge Reducer Pipe Lines At Unit Iv V Ac Plant Cooling Tower Etc
|
Description |
Ttps Operation Circle Mpm Ii Acp Reconditioning Of Cooling Tower C By Replacing Of Fills, Drift Eliminators, Spray Header Pipes, Overhauling Of 200 Nb 150 Nb Gate Valves, Eroded Discharge Reducer Pipe Lines At Unit Iv V Ac Plant Cooling Tower Etc
|
Organisation | Government of Tamil Nadu |
Tender Id | 2023_EB_393379_1 |
Reference Number |
CE/SE/O/TTPS/Spec.No.193/23-24 |
Tender Fee | 0 |
EMD | 5700 |
Tender Value | |
Place | O/o SE/O/TTPS |
Link | https://tntenders.gov.in |
Start Date | November 27, 2023 22:40 |
End Date |
12/12/2023 ( Expired 497 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Ttps operation circle mpm ii acp replacement of cooling tower a, b c structural supports, pipe line stand supports and motor lifting arrangement at unit-iv v ac plant
Ttps operation circle mpm ii acp replacement of cooling tower a, b c structural supports, pipe line stand supports and motor lifting arrangement at unit-iv v ac plant
Read moreMtps i mill plant ac plant unit ii coh 2024 25 air washer system epoxy painting of blowers, discharge duct spray system and air filter platform area replacing the damaged 200 nb gi header pipe vibration pads overhauling the blower 2
Mtps i mill plant ac plant unit ii coh 2024 25 air washer system epoxy painting of blowers, discharge duct spray system and air filter platform area replacing the damaged 200 nb gi header pipe vibration pads overhauling the blower 2
Read moreTtps operation circle cad acwph unit i annual overhauling dismantling and renewal of worn out and punctured pipes of bearing cooling water supply header 600 nb ms pipe line of unit i acw system near repair bay area
Ttps operation circle cad acwph unit i annual overhauling dismantling and renewal of worn out and punctured pipes of bearing cooling water supply header 600 nb ms pipe line of unit i acw system near repair bay area
Read moreTtps operation circle cad acwph unit i annual overhauling dismantling and renewal of worn out and punctured pipes of bearing cooling water return header 600 nb ms pipe line of unit i acw system near repair bay area
Ttps operation circle cad acwph unit i annual overhauling dismantling and renewal of worn out and punctured pipes of bearing cooling water return header 600 nb ms pipe line of unit i acw system near repair bay area
Read moreTtps operation circle mpm ii acp reconditioning of cooling tower a by renewing of louvers, wire meshes, angle structurals, water tank, valve overhauling and painting at switchyard-i
Ttps operation circle mpm ii acp reconditioning of cooling tower a by renewing of louvers, wire meshes, angle structurals, water tank, valve overhauling and painting at switchyard-i
Read moreTtps operation circle cad acwph unit ii captial overhauling dismantling and renewal of wornout, corroded and punctured pipes in cooling tower trough outlet 750/450 nb acw pumps common suction header, 400 nb pipe distribution pipes head
Ttps operation circle cad acwph unit ii captial overhauling dismantling and renewal of wornout, corroded and punctured pipes in cooling tower trough outlet 750/450 nb acw pumps common suction header, 400 nb pipe distribution pipes head
Read moreTtps operation circle cad acwph unit ii capital overhauling dismantling and renewal of wornout, damaged and punctured pipes of bearing cooling water supply and common discharge header 600 nb ms pipe line
Ttps operation circle cad acwph unit ii capital overhauling dismantling and renewal of wornout, damaged and punctured pipes of bearing cooling water supply and common discharge header 600 nb ms pipe line
Read moreTtps operation circle mpm ii acp reconditioning of cooling tower c by replacing of fills, drift eliminators, spray header pipes, overhauling of 200 nb 150 nb gate valves, eroded discharge reducer pipe lines at unit iv v ac plant cooling tower etc
Ttps operation circle mpm ii acp reconditioning of cooling tower c by replacing of fills, drift eliminators, spray header pipes, overhauling of 200 nb 150 nb gate valves, eroded discharge reducer pipe lines at unit iv v ac plant cooling tower etc
Read moreTtps operation circle mpm ii acp replacement of wornout 20 tr condenser in compressor b by reconditioned condenser and wornout 80 nb gate valves by new valves at switchyard-i
Ttps operation circle mpm ii acp replacement of wornout 20 tr condenser in compressor b by reconditioned condenser and wornout 80 nb gate valves by new valves at switchyard-i
Read moreTtps operation circle oeii fps erection of 125mtrs of 200nb m.s erw pipe line and 150 nb gate valve -1no for the replacement of wornout/damaged existing mulsifyre pipe lines of mvws system near unit-iv v bottom ash area
Ttps operation circle oeii fps erection of 125mtrs of 200nb m.s erw pipe line and 150 nb gate valve -1no for the replacement of wornout/damaged existing mulsifyre pipe lines of mvws system near unit-iv v bottom ash area