Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Supply Of 33 Kv Pilfer Proof Metering Cubicle (250/1 A) And 33 Kv Ct Pt Combined Unit (250/1 A)
|
| Description |
Supply Of 33 Kv Pilfer Proof Metering Cubicle (250/1 A) And 33 Kv Ct Pt Combined Unit (250/1 A)
|
| Organisation | Government of Uttar Pradesh |
| Tender Id | 2023_MVVNL_811599_1 |
|
Reference Number |
MEDCO/2763/2023 |
| Tender Fee | 5900 |
| EMD | 5500 |
| Tender Value | - |
| Place | MVVNL Head Quarter |
| Link |
View Original Tender Notice
https://etender.up.nic.in |
| Start Date | June 13, 2023 15:30 |
| End Date |
Expired
01/08/2023
Expired 1173 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Procurement of 33 kv 3 element outdoor type oil immersed combined metering unit of ct & pt of 0.2s accuracy class
Procurement of 33 kv 3 element outdoor type oil immersed combined metering unit of ct & pt of 0.2s accuracy class
Read moreProcurement of 11 kv, 3-phase, 4-wire ct-pt oil-immersed combined pole-mounted metering unit
Procurement of 11 kv, 3-phase, 4-wire ct-pt oil-immersed combined pole-mounted metering unit
Read moreProcurement of 11 kv 3 element outdoor type oil immersed combined metering unit of ct & pt of 0.2s accuracy class
Procurement of 11 kv 3 element outdoor type oil immersed combined metering unit of ct & pt of 0.2s accuracy class
Read moreFabrication of platform for installation of 02 nos 33 kv outdoor type vacuum circuit breakers along with control panels, ct and pt at main 33 kv receiving substation, 33 kv west substation, engagement of specialized agency for testing, commissioning
Fabrication of platform for installation of 02 nos 33 kv outdoor type vacuum circuit breakers along with control panels, ct and pt at main 33 kv receiving substation, 33 kv west substation, engagement of specialized agency for testing, commissioning
Read moreReplacement of damaged rusted and deteriorated ct and pt junction boxes installed in various 132 kv and 33 kv bays at 132 kv substation armapur kanpur nagar under 220 kv substation division panki kanpur
Replacement of damaged rusted and deteriorated ct and pt junction boxes installed in various 132 kv and 33 kv bays at 132 kv substation armapur kanpur nagar under 220 kv substation division panki kanpur
Read moreConstruction of ct, vcb and ptr foundation and cable trench at jhalda 33/11 kv sub-station under purulia division, dist.-purulia.
Construction of ct, vcb and ptr foundation and cable trench at jhalda 33/11 kv sub-station under purulia division, dist.-purulia.
Read moreSupply, installation, testing commissioning of 800 kva, 11 0.433 kv transformer and allied ht lt electrical works including rmu, ht metering cubicle, lt panel, apfc capacitor bank, cabling, earthing, civil works and statutory approvals
Supply, installation, testing commissioning of 800 kva, 11 0.433 kv transformer and allied ht lt electrical works including rmu, ht metering cubicle, lt panel, apfc capacitor bank, cabling, earthing, civil works and statutory approvals
Read moreAugmentation of grid station khellani from 100 mva to 150 mva along with sitc of 250 kva 33 0.433 kv auxiliary transformer sitc of 63 kva dg set replacement of 132 kv bus coupler panel and replacement of old 132 kv and amp 33 kv isolators at gss khel
Augmentation of grid station khellani from 100 mva to 150 mva along with sitc of 250 kva 33 0.433 kv auxiliary transformer sitc of 63 kva dg set replacement of 132 kv bus coupler panel and replacement of old 132 kv and amp 33 kv isolators at gss khel
Read moreE4963063 11kv and 33kv outdoor ct 01-sg4960097000-11 kv ct ratio ct 600-300_slash_1-1-0.5775a core-1-colon-15va 5p10 core-ii-colon-5va 0.2s core-iii-colon-cl.ps vk as per ann-a it-01,02-sg4960097019-33 kv ct ratio 400-200-100_slash_1-1-1 a core-1-colon-15va 5p10 core-ii-colon-5va 0.2s core-iii-colon-cl.ps vk-40i_rct_plus_10_ at lower tap as per ann-a it-02,03-not to quote,04-not to quote,05-not to quote
E4963063 11kv and 33kv outdoor ct 01-sg4960097000-11 kv ct ratio ct 600-300_slash_1-1-0.5775a core-1-colon-15va 5p10 core-ii-colon-5va 0.2s core-iii-colon-cl.ps vk as per ann-a it-01,02-sg4960097019-33 kv ct ratio 400-200-100_slash_1-1-1 a core-1-colon-15va 5p10 core-ii-colon-5va 0.2s core-iii-colon-cl.ps vk-40i_rct_plus_10_ at lower tap as per ann-a it-02,03-not to quote,04-not to quote,05-not to quote
Read moreMo 250 contactor 240v ac coil,spreader link kit mo 250 300a,empr 300i, 1 to 5.5a, 85v 265v,protection class ct, 5p10 200 1a,vaf meter, cl. 1,metering class ct 200 1a cl 1.0,mx0 22e 4p control contactor 240v ac,digital spp, 145 500v ac line voltage 2c o,gennext actuator, non-illum. fh red,gennext actuator, non-illum. fh green,gennext modular contact block, no,gennext modular contact block, nc,s6 1 pole 2 way with off 60 degree,gennext pro led indicator, red, 240v ac,gennext pro led indicator, yellow, 240v ac,gennext pro led indicator, blue, 240v ac,gennext pro led indicator, amber, 240v ac,mcb, tp, 10a, c-curve, 10ka,mcb, sp, 6a, c-curve, 10ka,lyra contacts male and female as per 400a rating incoming,retrofitting charges busbar and other accessories and work,lyra contacts male and female as per 400a rating outgoing
Mo 250 contactor 240v ac coil,spreader link kit mo 250 300a,empr 300i, 1 to 5.5a, 85v 265v,protection class ct, 5p10 200 1a,vaf meter, cl. 1,metering class ct 200 1a cl 1.0,mx0 22e 4p control contactor 240v ac,digital spp, 145 500v ac line voltage 2c o,gennext actuator, non-illum. fh red,gennext actuator, non-illum. fh green,gennext modular contact block, no,gennext modular contact block, nc,s6 1 pole 2 way with off 60 degree,gennext pro led indicator, red, 240v ac,gennext pro led indicator, yellow, 240v ac,gennext pro led indicator, blue, 240v ac,gennext pro led indicator, amber, 240v ac,mcb, tp, 10a, c-curve, 10ka,mcb, sp, 6a, c-curve, 10ka,lyra contacts male and female as per 400a rating incoming,retrofitting charges busbar and other accessories and work,lyra contacts male and female as per 400a rating outgoing
Read moreof your Industry type