| Particulars | Details |
|---|---|
| Title |
Miniature Circuit Breaker, 32 Amps, Isi Marked, Instantaneous Tripping Range:C, No. Of Poles (Pp=Protected Pole) Double Pole With 1 Pp, Rated Voltage 240 V, Rated Current In Amps:32 Conforming To Is:/Iec: 60898 1:2015, With Rated Short Circuit Current Capacity 10 Ka, Fixed Unadjustable Time Current Characteristics And Suitable For Use In Protection Of Industrial, Commercial And Domestic Electrical Installations. Mc Bs Shall Be Suitable For 50 Hz Ac Main Supplies And Have Facility For Termination O
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106360251 |
|
Reference Number |
73245157 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Kolkata |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/112024/106510258/viewNitPdf_4759452.pdf |
| Start Date | October 29, 2024 22:06 |
| End Date |
Expired
18/11/2024
Expired 698 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),mcb, 2p with 2pp 25a, type-b, rated sc current-10ka,mbcb, 2p with 2pp 32a, type-b, rated sc current-10ka
Miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),mcb, 2p with 2pp 25a, type-b, rated sc current-10ka,mbcb, 2p with 2pp 32a, type-b, rated sc current-10ka
Read more3 pole vacuum contactor, rated current 630 amp, size- s14 part no-3tf6844-0cq7, make-seimens
3 pole vacuum contactor, rated current 630 amp, size- s14 part no-3tf6844-0cq7, make-seimens
Read moreMpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.
Mpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.
Read moreMpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Read moreMpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Read moreFour pole change over switch disconnector mcb with centre position off(i-o-ii), rated current 40a, operational voltage 415v. makes: legrand / havells / c & s / schneider / abb or its equivalent. note: one sample should be got approved before effecting bulk supply.
Four pole change over switch disconnector mcb with centre position off(i-o-ii), rated current 40a, operational voltage 415v. makes: legrand / havells / c & s / schneider / abb or its equivalent. note: one sample should be got approved before effecting bulk supply.
Read moreMpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)
Mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)
Read moreContactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
Read morePower contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e
Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e
Read moreMotor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2
Motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2