Tender Details
Particulars | Details |
---|---|
Title |
Feeder Contactor Voltage Ratting 750 V A [Feeder Contactor Voltage Ratting 750 V Ac, Main Pole:4 Nos, Control Voltage:110 V Ac 50 60 Hz With Surge Suppessor, Ien/En 60947 4 1 For Net1&2, Suitable For Set Of Panels For Lhb Eog Non Ac Coaches. Make Abb Type Af50 40 Ca5 22 Erv5/240, Ui=1000 V,Ith=100 A,Ie Ac 1=100 A, Or Equivalent Of Siemens, L&T, Schneider, Note Firm Must Submit Proof Of Purchase From Oem Or Valid Authorized Dealer.]
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106367361 |
Reference Number |
78245253 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Mumbai |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/062024/106367361/viewNitPdf_4595695.pdf |
Start Date | June 05, 2024 20:55 |
End Date |
14/06/2024 ( Expired 333 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Power contactor 70 amps, 415 v, triple pole, with 2 no2nc aux contacts (side mounting), coil voltage 415v ac, confirming to is/iec 60947, part 4/sec 1. as per rcf specification no. edts-041, rev.-b. suitable for use in 200a battery charging unit of sg ac coaches. accepted make : siemens. abb, l&t. schneider only.
For complete deion and other details, please refer to tender
Read moreContactor for 60 kva transformer rated current: 95a, rated voltage: 690v ac, main pole: 4, auxiliary contact: 1 no1 nc, control voltage: 230v ac (168v ac-300v ac means 230v ac /- 30 percent ) with surge suppressor. as per sr.no.36 of d common bom of rdso no. el/7.1.108/mssbc dt-17.09.2021, makes are abb (cat. no. af 116 b-40), schneider (cat. no. lc1d1150046m5la4da2u), siemens (cat. no. 3rt2346-1np30-4aa0) or l&t (cat. no. mcx 23) only acceptable.
For complete deion and other details, please refer to tender
Read moreContactor k-44 for 60 kva transformer rated current -95 amp, rated voltage690 v ac, main pole - 4, auxillary contact 1 no 1 nc, control voltage - 230 volt ac (168 v ac300 v ac) with surge suppressor. place of location in sbc : s1k44conf make : abb, schneider, siemens & l&t only
For complete deion and other details, please refer to tender
Read moreK44 contactor for 60kva transformer rate [k44 contactor for 60kva transformer rated current: 200a, rated voltage:690v ac, main pole:4, aux contact :01no1nc, control voltage:230v ac (168 v ac-300 v ac means 230v ac /- 30 percent ) with surge suppressor as per item no.k01 of bill of material of rdso spec no. rdso/pe/spec/d/0184-2015 (rev.1) suitable for lhb type ac coaches switch board cabinet. brands: l&t/siemens/schneider/abb only. 1) the firm should submit authorized dealership certificate
For complete deion and other details, please refer to tender
Read moreContactor 3 pole, 16 amp capacity suitable for 415v, 50 hz ac, coil voltage 110 dc with surge suppressor ( coil voltage range 77-137 v dc) with inc auxiliery contack block similar to abb code tal-16-30-01, rt 5/150 generally conforming to is- 13947 pt.- 4/1993.] accepted makes: abb, schneider, siemens.
For complete deion and other details, please refer to tender
Read moreK44 contactor for 60kva transformer rate [k44 contactor for 60kva transformer rated current: 200a, rated voltage:690v ac, main pole:4, aux contact :01no1nc, control voltage:230v ac (168 v ac-300 v ac means 230v ac /- 30 percent ) with surge suppressor as per item no.k01 of bill of material of rdso spec no. rdso/pe/spec/d/0184-2015 (rev.1) suitable for lhb type ac coaches switch board cabinet. brands: l&t/siemens/schneider/abb only. 1) the firm should submit authorized dealership certificate
For complete deion and other details, please refer to tender
Read morePower contactor 110 amp. 4 pole 415 v ac [power contactor 110 amp. 4 pole 415 v ac coil voltage 380-415 v ac 50 hz with 2 nc aux contact along with surge suppresor as per s.no.59 & item no. k-08, place of installation s1k43 of bill of material of rdso spec no. rdso/pe/spec/ac/0184-2015(rev.0). brands: l&t/siemens/schneider/abb only 1) the firm should submit authorized dealership certificate or proof of purchase from oem dealer and necessary test certificates along with materials for acceptance
For complete deion and other details, please refer to tender
Read moreContactor(with diode) for ventilation fa [contactor(with diode) for ventilation fan unit 1&2 condenser cd1.1, cd1.2, cd 2.1, cd 2.2, heater 1&2 :rated current : 16 a (at rated voltage & ac-3 utilization category) rated voltage : 690 v ac, main pole : 3 no, aux contact : 1 nc, control voltage : 77-143v dc with surge suppressor. suitable for k26,k28,k31,k32,k36,k37,k35,k40 as per bom of rdso spec rdso/pe/spec/0184-2015(rev-01) or latest. brands: l&t/siemens/schneider/abb only. 1) the firm should
For complete deion and other details, please refer to tender
Read moreContactor for net 1 & net 2, rated volta [contactor for net 1 & net 2, rated voltage : 1000v ac, rated kva-100 at rated voltage & 70 degree centigrade and utilization category 6a. main pole :4, aux contact : 2no 2nc, control voltage: 415v ac /- 15 percent with surge suppressor, for lhb ac coaches . approved makes as per sr.no.3 of d common bom of rdso no.el/7.1.108/mssbc dt. 17.09.2021 conforming to spec no. rdso/pe/spec/ac/0184-2015 (rev.1) or latest will make and drawing/catologue
For complete deion and other details, please refer to tender
Read morePower contactor 110a, 3 pole, ac3 duty, coil voltage 415 v to 440 v ac with side mounting auxiliary contact block cal18/cel18, suitable for switch board cabinet of lhb power car. make: abb, type code: a110-30-11- coil code-86 (order code 1sfl 451 001 r8611) or equivalent make siemens type: 3tf-50 02-oaro/schneider/aeg note: oem or their authorized dealers with tender specific authorization letters from oem only to quote with documentary evidence.
For complete deion and other details, please refer to tender