Tender Details

Particulars Details
Title
Onsite Testing And Checking Of Different Protection Relays Installed In Circuit Breakers And Starters, Transformer Tests Of The 11 K V By 3.3 K V, 1.6 Mva Transformer Including D.G.A. Analysis Of The Transformer Oil, And The 3.3 K V Motors Installed At
Description
Onsite Testing And Checking Of Different Protection Relays Installed In Circuit Breakers And Starters, Transformer Tests Of The 11 K V By 3.3 K V, 1.6 Mva Transformer Including D.G.A. Analysis Of The Transformer Oil, And The 3.3 K V Motors Installed At
Organisation Central Coalfields Limited | Public Sector Undertakings
Tender Id 2025_CCL_330742_1
Reference
Number
P.E. (EnM)/ Karo OCP/ e-tender/ 2024-25/ 116
Tender Fee 0
EMD 3200
Tender Value
Place KARO OCP
Link
View Original Tender Notice

https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=342832

Start Date March 01, 2025 16:30
End Date
Expired 10/03/2025

Expired 479 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Onsite testing and calibration of protective relays and high voltage injection of circuit breakers ad dga analysis of transformer oil installed at 33 kv main substation of akkocp, bnk area

Onsite testing and calibration of protective relays and high voltage injection of circuit breakers ad dga analysis of transformer oil installed at 33 kv main substation of akkocp, bnk area

Read more
Onsite testing and checking of different protection and dga analysis of transformer oil at a periodic interval 03 month for 01 year installed at 33kv main sub-station ,mrss of bnk area

Onsite testing and checking of different protection and dga analysis of transformer oil at a periodic interval 03 month for 01 year installed at 33kv main sub-station ,mrss of bnk area

Read more
Onsite repair of the tripping arrangement bucholz relay h.t. bushing studs and other accessories of the 11 kv by 3.3 kv 1.6 mva sr. no. 4015095 eef make transformer installed at the 11 kv by 3.3 kv main substation of karo ocp under bnk area

Onsite repair of the tripping arrangement bucholz relay h.t. bushing studs and other accessories of the 11 kv by 3.3 kv 1.6 mva sr. no. 4015095 eef make transforme installed at the 11 kv by 3.3 kv main substation of karo ocp under bnk area

Read more
Onsite testing checking of different protection relay of switchgears (circuit breaker) and gas analysis (dga) of transformers installed in dd mines and gandhi nagar sub station in respect of bokaro colliery

Onsite testing checking of different protection relay of switchgears (circuit breaker) and gas analysis (dga) of transformers installed in dd mines and gandhi nagar sub station in respect of bokaro colliery

Read more
Periodic testing and calibration of protection relays associated with different 33 kv, 11 kv and 3.3 kv grade switches installed at both mine and 33 kv substation of giridih project.

Periodic testing and calibration of protection relays associated with different 33kv, 11kv and 3.3 kv grade switches installed at both mine and 33 kv substation, grd project.

Read more
Work of replacement of protection relays for 3.3 kv switchgears and motors at malad pumping station

Work of replacement of protection relays for 3.3 kv switchgears and motors at malad pumping station

Read more
Onsite repair cum prive maintenance of the 11 kv by 3.3 kv 2 mva sr. no. 458 a 4, east india electricals make transformer, installed at the 11 kv by 3.3 kv main substation of karo ocp, under bnk area.

Onsite repair cum prive maintenance of the 11 kv by 3.3 kv, 2 mva sr. no. 458 a 4 east india electricals make transformer, installed at the 11 kv by 3.3 kv main substation of karo ocp under bnk area.

Read more
Servicing of lt air circuit breakers, testing of relays, installed at different sub-stations of ecil and emsd cherlapally, ecil hyderabad.

Servicing of lt air circuit breakers, testing of relays, installed at different sub-stations of ecil and emsd cherlapally, ecil hyderabad.

Read more
Repair and maintenance of transformer, gang operated switches, ngr along with supply of the ngr relays different circuit breakers and filtration of transformer oil at different location.

Repair and maintenance of transformer, gang operated switches, ngr along with supply of the ngr relays different circuit breakers and filtration of transformer oil at different location.

Read more
Work of centrifusing of transformer oil of various 63 mva and 40 mva transformer installed at 132 kv s/s bhathat , f.c.i. -ii , f.c.i. old and mohaddipur old and oil testing of various transformer at different 132 kv and 220 kv substation under etd-i

Work of centrifusing of transformer oil of various 63 mva and 40 mva transformer installed at 132 kv s/s bhathat , f.c.i. -ii , f.c.i. old and mohaddipur old and oil testing of various transformer at different 132 kv and 220 kv substation under etd-i

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise