Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Onsite Testing And Checking Of Different Protection Relays Installed In Circuit Breakers And Starters, Transformer Tests Of The 11 K V By 3.3 K V, 1.6 Mva Transformer Including D.G.A. Analysis Of The Transformer Oil, And The 3.3 K V Motors Installed At
|
| Description |
Onsite Testing And Checking Of Different Protection Relays Installed In Circuit Breakers And Starters, Transformer Tests Of The 11 K V By 3.3 K V, 1.6 Mva Transformer Including D.G.A. Analysis Of The Transformer Oil, And The 3.3 K V Motors Installed At
|
| Organisation | Central Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2025_CCL_330742_1 |
|
Reference Number |
P.E. (EnM)/ Karo OCP/ e-tender/ 2024-25/ 116 |
| Tender Fee | 0 |
| EMD | 3200 |
| Tender Value | - |
| Place | KARO OCP |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=342832 |
| Start Date | March 01, 2025 16:30 |
| End Date |
Expired
10/03/2025
Expired 588 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Replacement of faulty protective relays along with complete testing of all protective relays associated with 220 kv and 132 kv feeders (including transformer feeders) and testing of 220 kv and 132 kv circuit breakers at 220/132 kv gss, adp-ii (rcp)
Replacement of faulty protective relays along with complete testing of all protective relays associated with 220 kv and 132 kv feeders (including transformer feeders) and testing of 220 kv and 132 kv circuit breakers at 220/132 kv gss, adp-ii (rcp)
Read moreUrgent repairs to 5 mva 33/3.3 kv transformer bearing sr. no 12psgo25/1 at 160 mld salauli water works. retendered 2nd call
Urgent repairs to 5 mva 33/3.3 kv transformer bearing sr. no 12psgo25/1 at 160 mld salauli water works. retendered 2nd call
Read moreManufacture, testing, supply and delivery of master trip and restricted earth fault relays for 11kv breakers and 66kv power transformers installed at various 66 kv substations
Manufacture, testing, supply and delivery of master trip and restricted earth fault relays for 11kv breakers and 66kv power transformers installed at various 66 kv substations
Read moreA installation and commissioning of 3.3 kv ngr in two nos merson s make 01 mva transformer installed at kalimati and shivmandir substation bearing sl no 11221 and 28672 respectively of chapapur colliery b installation and commissioning of 02 nos. 550
A installation and commissioning of 3.3 kv ngr in two nos merson s make 01 mva transformer installed at kalimati and shivmandir substation bearing sl no 11221 and 28672 respectively of chapapur colliery b installation and commissioning of 02
Read moreWork of checking the online health monitoring of cts, pts and las and work of residual life assessment of 25 mva power transformer at 220 kv substation chamba
Work of checking the online health monitoring of cts, pts and las and work of residual life assessment of 25 mva power transformer at 220 kv substation chamba
Read moreFor transformer oil collection and dga bdv ppm resistivity dielectric dissipation factor of various 220/400 kv / 132 kv power transformers installed at various s/s under etc-i kanpur
For transformer oil collection and dga bdv ppm resistivity dielectric dissipation factor of various 220/400 kv / 132 kv power transformers installed at various s/s under etc-i kanpur
Read moreSeparate delta earthing work for lightning arrestor la installed on 72 no power transformer installed at 38 additional 33 11 kv power sub station of edd badlapur shahganj machhalishahar junpur under etd ii jaunpur
Separate delta earthing work for lightning arrestor la installed on 72 no power transformer installed at 38 additional 33 11 kv power sub station of edd badlapur shahganj machhalishahar junpur under etd ii jaunpur
Read more(a) erection /dismantling of poles along with conductors and other associated accessories 3.3 kv o/h line (feeder 1, feeder 2 , feeder 3 and feeder 4), and installation of 11 kv grade goab switch, installation of lighting transformer, switch shifting
(a) erection /dismantling of poles along with conductors and other associated accessories 3.3 kv o/h line (feeder 1, feeder 2 , feeder 3 and feeder 4), and installation of 11 kv grade goab switch, installation of lighting transformer, switch shifting
Read moreSupply, installation and commissioning of siv testing panel (100 kva oil cooled transformer) as per attached specification. note: the siv testing panel shall be suitable for testing, checking and performance verification of 180 kva / 2x130kva static inverters (sivs) used in wag-7 electric locomotives.the panel shall be capable of simulating operating conditions and conducting functional, load and protection tests of siv units. the firm shall supply, install and commission the complete siv test
Supply, installation and commissioning of siv testing panel (100 kva oil cooled transformer) as per attached specification. note: the siv testing panel shall be suitable for testing, checking and performance verification of 180 kva / 2x130kva static inverters (sivs) used in wag-7 electric locomotives.the panel shall be capable of simulating operating conditions and conducting functional, load and protection tests of siv units. the firm shall supply, install and commission the complete siv test
Read morePlug and socket,roller bearing, nu 220 emi, cylindrical, single,start - stop micro switch,cable kit, heat shrnk, 3.3 kv, 70 mm2, 3 c,roller bearing, 22220 k, spherical, dbl, 100 mm,bolt, hex, cs, ht, half, 22mm,125 mm with nut,roller bearing, n318, cylindrical, single, 90 mm,bearing ball, 6316, dp, grv, single, 80 mm, 170 mm,relay cntrl, pla, 12 v ac, 8 pin,bearing ball, rms 24, dpgrv, single, 76.2 mm,diode, by 127, silicon,shaft with keys and sleeve nuts for 6 sta,isolator 3.3 kv, 400 amps on off complete,potential transformer, 550 - 220v, 50va,bearing ball, als-40, anglr, cntct, single
Plug and socket,roller bearing, nu 220 emi, cylindrical, single,start - stop micro switch,cable kit, heat shrnk, 3.3 kv, 70 mm2, 3 c,roller bearing, 22220 k, spherical, dbl, 100 mm,bolt, hex, cs, ht, half, 22mm,125 mm with nut,roller bearing, n318, cylindrical, single, 90 mm,bearing ball, 6316, dp, grv, single, 80 mm, 170 mm,relay cntrl, pla, 12 v ac, 8 pin,bearing ball, rms 24, dpgrv, single, 76.2 mm,diode, by 127, silicon,shaft with keys and sleeve nuts for 6 sta,isolator 3.3 kv, 400 amps on off complete,potential transformer, 550 - 220v, 50va,bearing ball, als-40, anglr, cntct, single