Tender Details
Particulars | Details |
---|---|
Title |
Supply,Erection,Testing And Commissioning Of Following Works In Adilabad (Erstwhile) District On Turnkey Basis. Lot I: 132/33 Kv Substation Tallapet (Ii) 132 Kv Dc Line (13 Km) For Making Lilo Of 132 Kv Dharmapuri Luxettipet To 132/33 Kv Ss Tallapet. Lot Ii: 220 Kv Dc Line (3.145 Km) For Making Lilo Of One Circuit Of 220 Kv Jagityal Nirmal Line To 400 Kv Ss Nirmal. Lot Iii: (I) Making Lilo Of 132 Kv Pochampadu Nirmal With 2nd Circuit Stringing (33 Km) To 132 Kv Ss Burugupally And Connected Bay.
|
Description |
Supply,Erection,Testing And Commissioning Of Following Works In Adilabad (Erstwhile) District On Turnkey Basis. Lot I: 132/33 Kv Substation Tallapet (Ii) 132 Kv Dc Line (13 Km) For Making Lilo Of 132 Kv Dharmapuri Luxettipet To 132/33 Kv Ss Tallapet. Lot Ii: 220 Kv Dc Line (3.145 Km) For Making Lilo Of One Circuit Of 220 Kv Jagityal Nirmal Line To 400 Kv Ss Nirmal. Lot Iii: (I) Making Lilo Of 132 Kv Pochampadu Nirmal With 2nd Circuit Stringing (33 Km) To 132 Kv Ss Burugupally And Connected Bay.
|
Organisation | Information Technology Electronics and Communication Department Telangana | State Govt. and UT |
Tender Id | 583448 |
Reference Number |
TGT-CONST-e14/2024-25 |
Tender Fee | 11800 |
EMD | 45.54 Lakh |
Tender Value | |
Place | TS |
Link | http://eprocurement.telangana.gov.in/ |
Start Date | March 21, 2025 23:30 |
End Date |
22/04/2025 ( Expired 18 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Supply erection of 220/132/33kv ss at chinnamadur(singarajupally) and connected 220kv 132kv lines and 132kv bays in erstwhile warangal dist
Supply, erection, testing and commissioning of (i) 220/132/33kv ss at chinnamadur (singarajupally) with 2x160mva 2x50mva ptrs including 220 kv twin moose double bus system. (ii) 220kv dc line to proposed 220/132/33kv ss chinnamadur by making lilo of 220kv sc line 220kv ss waddekothapally - 400/220 kv ss jangoan (6 km) (iii) 132kv dc/sc line from proposed 220/132/33kv ss chinnamadur to existing 132/33kv ss palakurthy (12 km) (iv) 132kv dc/sc line from proposed 220/132/33kv ss chinnamadur to existing 132/33kv ss raghunathpally (18 km) (v) 132kv dc/sc line from proposed 220/132/33kv ss chinnamadur to existing 132/33kv ss mothkur (26 km) (vi) 3nos 132kv bays (1no.at 132kv ss mothkur, 1no.at 132kv ss palakurthy 1no. at 132kv ss raghunathpally) in jangaon dist on turnkey basis
Read moreSupply, erection, testing, commissioning of following works in nizamabad (erstwhile) district on turnkey basis. lot-i: 132/33kv ss pitlam (2x50mva ptrs) ii) 132kv dc/sc line (26.5km) from 220/132/33kv ss banswada to proposed 132/33kv ss pitlam iii) 132kv feeder bay at 220kv ss banswada lot-ii: (i) 220kv dc line (43km) from existing 220/132kv ss kamareddy to 220/11kv liss at yacharam thanda and connected 220kv bays
Supply, erection, testing and commissioning of following works in nizamabad (erstwhile) district on turnkey basis. lot-i: 132/33kv ss pitlam (2x50mva ptrs) ii) 132kv dc/sc line (26.5km) from 220/132/33kv ss banswada to proposed 132/33kv ss pitlam iii) 132kv feeder bay at 220kv ss banswada lot-ii: (i) 220kv dc line (43km) from existing 220/132kv ss kamareddy to 220/11kv liss at yacharam thanda ii) 1no. 220kv bay extension including bus extension at 220/132kv ss kamareddy (iii) 2nos. 220kv bay extensions at 220/11kv ss yacharam thanda (iv) 220kv bay extension at 220/132kv ss kamareddy
Read moreSupply, erection, testing and commissioning of (a) 132kv ss valigonda and 132kv dc/sc line (17.5km) from ramannapet ss (b) 132kv dhandumalkapur ss and 132kv dc line (17.5km) from 400kv choutuppal ss in yadadri - bhongir district (c) 132kv dc/sc line (13km) from 220kv ss madgula to 132kv ss godakandla in nalgonda district on turnkey basis.
Supply, erection, testing and commissioning of (a) 132kv valigonda ss and 132kv dc/sc line (17.5km) from 132kv ramannapet ss (b) 132kv dhandumalkapur ss and 132kv dc line (17.5km) from 400kv choutuppal ss in yadadri-bhongir district (c) 132kv dc/sc line (13km) from existing 220kv ss madgula ss to 132kv ss godakandla in nalgonda district on turnkey basis.
Read moreRenovation/up-gradation of 132kv (dc) wanpoh awantipora lilo bay replacement of old detorated 33kv equipments and conductor augmentation at 132/33kv gss wanpoh
Renovation/up-gradation of 132kv (dc) wanpoh awantipora lilo bay replacement of old detorated 33kv equipments and conductor augmentation at 132/33kv gss wanpoh
Read moreSupply,erection,testing and commissioning of following works in adilabad (erstwhile) district on turnkey basis. lot-i: 132/33kv substation tallapet (ii) 132kv dc line (13km) for making lilo of 132kv dharmapuri-luxettipet to 132/33kv ss tallapet. lot-ii: 220kv dc line (3.145km) for making lilo of one circuit of 220kv jagityal-nirmal line to 400kv ss nirmal. lot-iii: (i) making lilo of 132kv pochampadu-nirmal with 2nd circuit stringing (33km) to 132kv ss burugupally and connected bay.
Supply,erection,testing and commissioning of following works in adilabad (erstwhile) district on turnkey basis. lot-i: 132/33kv substation tallapet (ii) 132kv dc line (13km) for making lilo of 132kv dharmapuri-luxettipet to 132/33kv ss tallapet. lot-ii: 220kv dc line (3.145km) for making lilo of one circuit of 220kv jagityal-nirmal line to 400kv ss nirmal. lot-iii: (i) making lilo of 132kv pochampadu-nirmal with 2nd circuit stringing (33km) to 132kv ss burugupally and connected bay.
Read moreSupply, erection, testing and commissioning of i) 2nd circuit stringing on existing 132kv dc/sc line (30km) from 220/132kv budidampadu ss to 132/33kv yellandu ss ii) 1no. 132kv bay at 220/132kv ss budidampadu and iii) 1no. 132kv bay at 132kv ss yellandu in khammam district on turnkey basis
Supply, erection, testing and commissioning of i) 2nd circuit stringing on existing 132kv dc/sc line (30 km) from 220/132kv budidampadu ss to 132/33kv yellandu ss, ii) 1no 132kv bay at 220/132kv ss budidampadu and iii) 1no 132kv bay at 132kv ss yellandu in khammam district on turnkey basis.
Read moreSupply, erection, testing and commissioning of following works in mahaboobnagar district on turnkey basis loti: 132/33kv ss kondapur, 132kv dc/sc line from maddur to kondapur (7km) lot ii: 132/33kv ss vemula, 132kv dc/sc line from khillaghanapur to vemula (13km),1no 132kv bay at khillaghanapur lotiii:33kv features at 220kv ss thimmajipeta , lot iv:33kv features at 132/11kv kothakota lis
Supply, erection, testing and commissioning of following works in mahaboobnagar district on turnkey basis loti: 132/33kv ss kondapur, 132kv dc/sc line from maddur to kondapur (7km) lot ii: 132/33kv ss vemula, 132kv dc/sc line from khillaghanapur to vemula (13km),1no 132kv bay at khillaghanapur lotiii:33kv features at 220kv ss thimmajipeta , lot iv:33kv features at 132/11kv kothakota lis
Read moreSupply, erection, testing and commissioning of upgradation of existing 132kv ss chinnashankarampet to 220kv ss, 220kv dc line from 400kv ss narsapur to chinnashankarampet, 2nd circuit stringing on 132kv line from medak to ramayampet and making lilo to chinnashenkarampet along with 2nos 220kv bays at narsapur 400kv ss, 1no 132kv bay at medak ss and 1no 132kv bay at ramayampet ss in sangareddy district on turnkey basis
Supply, erection, testing and commissioning of existing 132kv ss chinnashenkarampet to 220kv ss, 220kv dc line from 400kv ss narsapur, 2nd circuit stringing on 132kv dc/sc line from medak-ramayampet and making lilo to 220kv ss chinnashenkarampet along with 2nos 220kv bays at narsapur 400kv ss, 1no 132kv bay at medak 132kv ss and 1no 132kv bay at ramayampet 132kv ss in sanagreddy disctrict on turnkey basis.
Read moreWc-4124-b-making temporary bypass arrangement for ht 33kv and 11kv and lt 415v line crossings during stringing of 765kv koppal-ii ps - raichur dc transmission line (tl02)
Making temporary bypass arrangement for ht 33kv and 11kv and lt 415v line crossings during stringing of 765kv koppal-ii ps - raichur dc transmission line (tl02)
Read moreWc-4124-a-making temporary bypass arrangement for ht 33kv and 11kv and lt 415v line crossings during stringing of 765kv koppal-ii ps - raichur dc transmission line (tl01)
Making temporary bypass arrangement for ht 33kv and 11kv and lt 415v line crossings during stringing of 765kv koppal-ii ps - raichur dc transmission line (tl01)
Read moreof your Industry type