Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Repairing And Maintenance Of 02 Nos 10 Mva, 33 Kv/11 Kv Power Transformer On Site And Upgradation And Adoption Earth Leakage Relay With Cbct System In Control Switches At Gidi Washery Substation.
|
| Description |
Repairing And Maintenance Of 02 Nos 10 Mva, 33 Kv/11 Kv Power Transformer On Site And Upgradation And Adoption Earth Leakage Relay With Cbct System In Control Switches At Gidi Washery Substation.
|
| Organisation | Central Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2025_CCL_343147_1 |
|
Reference Number |
PE(EnM)/GDW/eNT/25-26/02 (A) Dated 03.09.2025 |
| Tender Fee | 0 |
| EMD | 11600 |
| Tender Value | - |
| Place | Gidi-Washery Project |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=355706 |
| Start Date | September 04, 2025 14:30 |
| End Date |
Expired
13/09/2025
Expired 350 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Repairing and maintenance of 02 nos 10mva, 33kv/11kv power transformer on site and upgradation and adoption earth leakage relay with cbct system in control switches at gidi washery substation.
Repairing and maintenance of 02 nos 10mva, 33kv/11kv power transformer on site and upgradation and adoption earth leakage relay with cbct system in control switches at gidi washery substation
Read moreProviding and fixing of 14 no earth leakage relay with cbct at both 33kv and 11kv substation under urimari ocp.
Providing and fixing of 14 no earth leakage relay with cbct and its
 accessories for installation on different vcb(both 11kv and 3.3kv) at both 33kv and 11kv substation
 under urimari ocp.
Read moreUp-gradation and adoption of earth leakage relay with cbct system in 8 nos 11kv/3.3kv 630amp vcb meditron and mineline make at gidi-c colliery under argada area
Up-gradation and adoption of earth leakage relay with cbct system in 8 nos 11kv/3.3kv 630amp vcb meditron and mineline make at gidi-c colliery under argada area
Read moreUp-gradation and adoption of earth leakage relay with cbct system in 8 nos 11kv/3.3kv ,630amp vcb meditron and mineline make at gidi-c colliery under argada area
Up-gradation and adoption of earth leakage relay with cbct system in 8 nos 11kv/3.3kv ,630amp vcb meditron and mineline make at gidi-c colliery under argada area
Read moreUp-gradation and adoption of earth leakage relay with cbct system in 8 nos 11kv/3.3kv ,630amp vcb meditron and mineline make at gidi-c colliery under argada area.
Up-gradation and adoption of earth leakage relay with cbct system in 8 nos 11kv/3.3kv ,630amp vcb meditron and mineline make at gidi-c colliery under argada area.
Read moreFor 11kv bus-bar arrangement for 10mva 33kv 11kv transformer make sambhav at regional substation of kathara colliery
For 11kv bus-bar arrangement for 10mva 33kv 11kv transformer make sambhav at regional substation of kathara colliery
Read moreUpgradation and adoption of earth leakage relay with cbct system in 9 nos. 11kv/3.3kv, 630a vcb meditron and mineline make at jocp main substation under hazaribagh area
Upgradation and adoption of earth leakage relay with cbct system in 9 nos. 11kv/3.3kv, 630a vcb meditron and mineline make at jocp main substation under hazaribagh area
Read moreUpgradation and adoption of earth leakage relay with cbct system in 6 nos.11kv/3.3kv, 630amp vcb meditron and main line make at karma main substation under kuju area.
Upgradation and adoption of earth leakage relay with cbct system in 6 nos.11kv/3.3kv, 630amp vcb meditron and main line make at karma main substation under kuju area.
Read moreReplacement of 33 kv ct200/100/5 and pt 33kv/110volt of protection system of 10 mva, 33kv/11kv power transformer at gidi washery main substation, under argada area.
Replacement of 33 kv ct200/100/5 and pt 33kv/110volt of protection system of 10 mva, 33kv/11kv power transformer at gidi washery main substation, under argada area.
Read moreSupply and fixing earth leakage relay in 11kv vcb at golakdih 33kv/11 kv substation.
Supply and fixing earth leakage relay in 11kv vcb at golakdih 33kv/11 kv substation.