Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation.Installation Of 2x63 Kva. 100 Kva Sub Stn. Alongwith Erection Of 11 Kv Line On 9 Mtr. St Poles, 30mm Sq Acsr Weasel Cond. At Wss Serbala Under Jjm
|
| Description |
Creation.Installation Of 2x63 Kva. 100 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. St Poles, 30mm Sq Acsr Weasel Conductor . Lt Line On 8 Mtr. St Pole At Wss Serbala Under Jjm
|
| Organisation | DC-PDD | State Govt. and UT |
| Tender Id | 2025_PDD_274638_1 |
|
Reference Number |
ED/UDH/51 of 2024-25 dt. 19-03-2025 |
| Tender Fee | 1000 |
| EMD | 78200 |
| Tender Value | - |
| Place | In District Udhampur |
| Link |
View Original Tender Notice
https://jktenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=847116 |
| Start Date | March 20, 2025 21:30 |
| End Date |
Expired
09/04/2025
Expired 552 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Read moreAttending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Read moreSurvey, supply, transportation, carriage, erection, testing and commissioning for creation of 4x63 kva sub station alongwith erection of 11 kv line on 9 mtr. long st poles, 30mm sq acsr weasel conductor at wss serbala under jjm scheme
Creation of 4x63 kva sub station alongwith erection of 11 kv line on 9 mtr. long st poles, 30mm sq acsr weasel conductor, lt line on 8 mtr. st pole at wss serbala under jjm
Read moreSurvey, supply, transportation, carriage, erection, testing and commissioning for creation of 3x250, 2x63 kva sub stations alongwith erection of 11 kv line on 9 mtr. st poles, 30mm sq acsr weasel conductor at wss kud lower under jjm scheme
Creation of 3x250, 2x63 kva sub stations alongwith erection of 11 kv line on 9 mtr. st poles, 30mm sq acsr weasel conductor, lt line on 8 mtr. st pole at wss kud lower under jjm
Read moreSurvey, supply, transportation, carriage, erection, testing and commissioning for creation of 2x250 kva, 2x63 kva sub stns. alongwith erection of 11 kv line on 9 mtr. st poles, 30mm sq acsr cond., lt line on 8 mtr. st pole at wss kashirah under jjm
Creation of 2x250 kva, 2x63 kva sub stations alongwith erection of 11 kv line on 9 mtr. st poles, 30mm sq acsr conductor, lt line on 8 mtr. st pole at wss kashirah under jjm
Read moreSurvey, supply, transportation, carriage, erection, testing and commissioning for creation of 100 kva, 2x63 kva sub stns. alongwith erection of 11 kv line on 9 mtr. st poles, 30mm sq acsr cond,. lt line on 8 mtr. st pole at wss kashirah under jjm
Creation of 100 kva, 2x63 kva sub stations alongwith erection of 11 kv line on 9 mtr. st poles, 30mm sq acsr conductor, lt line on 8 mtr. st pole at wss kashirah under jjm
Read moreSurvey, supply, transportation, carriage, erection, testing and commissioning for creation of 2x63 kva sub stn. alongwith erection of 11 kv line on 9mtr. st poles, 30mm sq. acsr weasel conductor, lt line on 8 mtr. st pole wss ser manjla under jjm
Creation of 2x63 kva sub station alongwith erection of 11 kv line on 9mtr. st poles, 30mm sq. acsr weasel conductor, lt line on 8 mtr. st pole at wss ser manjla
Read moreSurvey, supply, transportation, carriage, erection, testing and commissioning for creation of 2x250. 2x63 kva sub stns. alongwith erection of line on 9 mtr. st poles, 30mm sq acsr rabbit cond. lt 8 mtr. st pole at wss laddan kalid sulghar under jjm
Creation of 2x250 kva . 2x63 kva sub stations alongwith erection of 11 kv line on 9 mtr. st poles, 30mm sq acsr rabbit conductor . lt line on 8 mtr. st pole at wss laddan kalid sulghar under jjm
Read moreSurvey, supply, transportation, carriage, erection, testing and commissioning for creation of 63 kva, 100 kva sub station alongwith erection of 11 kv line on 9 mtr. st poles, 30mm sq acsr weasel cond., lt line on 8 mtr. st pole wss kidmoo under jjm
Creation of 63 kva, 100 kva sub station alongwith erection of 11 kv line on 9 mtr. st poles, 30mm sq acsr weasel conductor, lt line on 8 mtr. st pole at wss kidmoo
Read moreSurvey, supply, transportation, carriage, erection, testing and commissioning for creation of 250 kva, 400 kva ss alongwith erection of 11 kv line on 9 mtr. long st poles, 30mm sq acsr weasel cond. lt line on 8 mtr. st pole wss paryan under jjm
Creation of 250 kva 400 kva sub station alongwith erection of 11 kv line on 9 mtr. long st poles, 30mm sq acsr weasel conductor lt line on 8 mtr. long st pole at wss paryan
Read moreof your Industry type