Tender Details
Check your funding eligibility in 2 minutes.
Answer a few questions and our team will contact you with your best options.
Particulars | Details |
---|---|
Title |
S I T C Of 1plus2 630 Amps 11 Kv Vacuum Circuit Breaker Vcb Ht Panel With Provision Of Standby Ht Service Cable For Existing 1x500 Plus 1x400 Kva Indoor Type Transformer Substation
|
Description |
S I T C Of 1plus2 630 Amps 11 Kv Vacuum Circuit Breaker Vcb Ht Panel With Provision Of Standby Ht Service Cable For Existing 1x500 Plus 1x400 Kva Indoor Type Transformer Substation
At Main Telephone Exchange Campus Ranchi.
|
Organisation | Bharat Sanchar Nigam Limited (Govt of India Enterprise) | Public Sector Undertakings |
Tender Id | 2024_BSNL_213510_1 |
Reference Number |
DNIT/CEE/JKD/RCH/2024-25/07 |
Tender Fee | 590 |
EMD | 38914 |
Tender Value | |
Place | Main TE ranchi |
Link | https://etenders.gov.in/eprocure/app?page=FrontEndTenderDetailsExternal&service=page&tnid=235442 |
Start Date | November 05, 2024 22:25 |
End Date |
21/11/2024 ( Expired 206 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Fabrication and supply of indoor type multipanel unitized substation with vcb panel 1_ incomer_ and 2 outgoing lbs for 500 kva cast resin transformer with oltc and for existing 315kva oil cooled transformer,transformer will be kel make
Fabrication and supply of indoor type multipanel&#x0d unitized substation with vcb panel 1_ incomer_ and 2 outgoing lbs for&#x0d 500 kva cast resin transformer with oltc and for existing&#x0d 315kva oil cooled transformer,transformer will be kel make &#x0d
Read moreRenovation of electrical installations fans including replacement of old existing l t meter panel service connection cable allied electrical works for 9 nos type ii staff quarters in c block at katol road p t colony nagpur 2nd call
Renovation of electrical installations fans including replacement of old existing l t meter panel service connection cable allied electrical works for 9 nos type ii staff quarters in c block at katol road p t colony nagpur 2nd call
Read moreRenovation of electrical installations andfans including replacement of old existing lt meter panel and service connection cable and allied electrical works for 9 nos type ii staff quarters in c block at katol road p and t colony nagpur nagpur region
Renovation of electrical installations andfans including replacement of old existing lt meter panel and service connection cable and allied electrical works for 9 nos type ii staff quarters in c block at katol road p and t colony nagpur nagpur region
Read moreSpl repair to 11 kv ht line rmu substation inter connection apfc panel standby ht cable and special repair to indoor 33 kv/11kv vcbs rmus four pole structure and two pole structure under ge mcte mhow
Spl repair to 11 kv ht line rmu substation inter connection apfc panel standby ht cable and special repair to indoor 33 kv/11kv vcbs rmus four pole structure and two pole structure under ge mcte mhow
Read moreService maintenance and testing of transformer, lt air circuit breaker panel and sf6 type ht circuit breaker panel at substations 1, 2, 3 and 4 at iim lko
Service maintenance and testing of transformer, lt air circuit breaker panel and sf6 type ht circuit breaker panel at substations 1, 2, 3 and 4 at iim lko
Read moreComplete installation, testing and commissioning of vacuum circuit breaker 33 kv grade, 33kv control panel with ct and pt, 2 mva transformer, 33 kv/ 3.3kv, 3.3 kv indoor vcb panels at main sub-station of amadand ug mine
Complete installation, testing and commissioning of vacuum circuit breaker 33 kv grade, 33kv control panel with ct and pt, 2 mva transformer, 33 kv/ 3.3kv, 3.3 kv indoor vcb panels at main sub-station of amadand ug mine
Read moreDismantling transportation test comm of 11kv ht vcb panel from cgmt to te halsuru and 2x 630 kva indoor distribution transformer oil filtration and misc electrical works bangalore
Dismantling transportation test comm of 11kv ht vcb panel from cgmt to te halsuru and 2x 630 kva indoor distribution transformer oil filtration and misc electrical works bangalore
Read moreSingle bottle vcb (single interrupter vacuum circuit breaker type 22 cb schneider make), rated voltage: 25 kv single phase rated current: 1000 amp (rms), rated frequency:50 hz, short time current:16 kamp rms (400 mva), rated short circuit making current: 40 kamp peak, rated power frequency voltage (dry & wet):75 kv rms, no. of phase: one, total weight:125 kg (approx.). note: 1. fixing arrangement of vcb should be same as existing schneider make vcb drawing no. clw/es/sk-8/c-47/i. 2. the locati
For complete deion and other details, please refer to tender
Read moreMake base to install 11kv outdoor type vcb control of 3mva, 11 kv or3.3 kv p transformer,3.3kv outdoor type vcb as control of 3.3kv power of f- 1,cable lying, connection work ,s/f g. bush,clamp in control switch gear at 4 mva,11kv/3.3 main substation
Make base to install 11kv outdoor type vcb control of 3mva, 11 kv or3.3 kv p transformer,3.3kv outdoor type vcb as control of 3.3kv power of f- 1,cable lying, connection work ,s/f g. bush,clamp in control switch gear at 4 mva 11kv/3.3 main substation
Read moreDismantling transportation testing and commissioning of 11kv ht vcb panel from o/c cgmt halasuru to te halsuru and 2x 630 kva indoor distribution transformer oil filtration and misc electrical works bangalore
Dismantling transportation testing and commissioning of 11kv ht vcb panel from o/c cgmt halasuru to te halsuru and 2x 630 kva indoor distribution transformer oil filtration and misc electrical works bangalore 
 
Read moreof your Industry type