Repairing Of Reroll England Make Ocb, 200 A, 3.3k V Switch Gear Main For Controlling Of 150 Kva And 300 Kva 3.3k V /440 V Lighting Transformer At Officer Colony, Babu Dangal Sub Station (Nlocp).
|
| Description |
Repairing Of Reroll England Make Ocb, 200 A, 3.3k V Switch Gear Main For Controlling Of 150 Kva And 300 Kva 3.3k V /440 V Lighting Transformer At Officer Colony, Babu Dangal Sub Station (Nlocp).
|
| Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
| Tender Id | 2024_BCCL_298215_1 |
|
Reference Number |
BCCL/CV/XII/EnM/ TENDER/2023-24/165 |
| Tender Fee | 0 |
| EMD | 1800 |
| Tender Value | - |
| Place | NLOCP/Laikdih |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=308886 |
| Start Date | January 11, 2024 18:30 |
| End Date |
Expired
20/01/2024
Expired 980 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Repairing and renovating of 02 nos of controlling switches (a) ece make, 3.3kv, 400a ocb switch used for controlling of 500kva transformer and (b) meditron make, 3.3kv, 400a vcb switch used for controlling of 300kva transformer installed at iwsp, bnk
Repairing and renovating of 02 nos of controlling switches (a) ece make, 3.3kv, 400a ocb switch used for controlling of 500kva transformer and (b) meditron make, 3.3kv, 400a vcb switch used for controlling of 300kva transformer installed at iwsp, bnk
Read moreRepairing and maintenance of 400 amphere ocb switch make southern switch gear 3.3kv sl. no0612/863 controlling of 300kva nagina bazaar under bhowra power house
Repairing and maintenance of 400 amphere ocb switch make southern switch gear 3.3kv sl. no0612/863 controlling of 300kva nagina bazaar under bhowra power house
Read moreEgression n instatement of 04 nos. of transformers namely 1. 300kva, 3.3kv/550v 2. 160kva, 3.3kv/440v 3. 500kva, 3.3kv/550v 4. 630kva, 3.3kv/550v and 03 nos. of controlling switches (vcbs/ocbs) including renovation of transformer foundations, control
Egression n instatement of 04 nos. of transformers namely 1. 300kva, 3.3kv/550v 2. 160kva, 3.3kv/440v 3. 500kva, 3.3kv/550v 4. 630kva, 3.3kv/550v and 03 nos. of controlling switches (vcbs/ocbs) including renovation of transformer foundations, control
Read moreRepairing of 3.3kv, 400amps gec make ocb switch sl no. m-628 for controlling of secondary 3.3kv switch of darnoda albion sub-station of damoda colliery.
Repairing of 3.3kv, 400amps gec make ocb switch sl no. m-628 for controlling of secondary 3.3kv switch of darnoda albion sub-station of damoda colliery.
Read moreRepairing of 3.3kv, 100-amps, m.v. make ocb s.no. sdp/pnm/67 and 3.3kv, 400-amps, biecco lawrie make ocb secondary main controlling switch of 1-mva power transformer of sheetalpur colliery under sodepur area
Repairing of 3.3kv, 100-amps, m.v. make ocb s.no. sdp/pnm/67 and 3.3kv, 400-amps, biecco lawrie make ocb secondary main controlling switch of 1-mva power transformer of sheetalpur colliery under sodepur area
Read moreRepairing and maintenance of 3.3kv, 400a ocb switch gec sl.no- mocp/ocb/m/541 for controlling of domestic power supply of barora thana and muraidih colony in amp colliery.
Repairing and maintenance of 3.3kv, 400a ocb switch 
 gec sl.no- mocp/ocb/m/541 for controlling of domestic 
 power supply of barora thana and muraidih colony in 
 amp colliery.
Read moreComplete repairing of 400amp 11kv ocb with busbar biecco lowrie for primary controlling 11kv/3.3kv transformer at 07 no sub station abdkc.
Complete repairing of 400amp 11kv ocb with busbar biecco lowrie for primary controlling 11kv/3.3kv transformer at 07 no sub station abdkc.
Read moreRepairing of 3.3kv 400amp ocb switch controlling to 2000 kva power transformer as secondary switch installed at view point 11kv sub station.
Repairing of 3.3kv 400amp ocb switch controlling to 2000 kva power transformer as secondary switch installed at view point 11kv sub station.
Read moreRepairing of 3.3kv, 400amps gec make ht ocb switch for controlling of 500kva transformer kkc link siding substation of phularitand, amp colliery.
Repairing of 3.3kv, 400amps gec make ht ocb switch 
 for controlling of 500kva transformer kkc link siding 
 substation of phularitand, amp colliery.
Read moreRepairing/reconditioning of 3.3kv, 400a, reyroll burn make ocb. sl.no. 82/104, installed at dumerbera sub-station for controlling 3.3kv power supply 10 16b quarry of ara colllery. repairing/reconditioning of 11 kv, 400 amp, ocb of ara colliery.
Repairing/reconditioning of 3.3kv, 400a, reyroll burn make ocb. sl.no. 82/104, installed at dumerbera sub-station for controlling 3.3kv power supply 10 16b quarry of ara colllery. repairing/reconditioning of 11 kv, 400 amp, ocb of ara colliery.