Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Repairing And Replacement Of Fire Fighting Pumps Panel Hydrant Valves And Piping Work In Kd Cse Building Iit Kanpur
|
| Description |
Repairing And Replacement Of Fire Fighting Pumps Panel Hydrant Valves And Piping Work In Kd Cse Building Iit Kanpur
|
| Organisation | Indian Institute of Technology Kanpur | Central Govt. Ministry/Department |
| Tender Id | 2025_IITK_873642_1 |
|
Reference Number |
23/AC/EE/2025 |
| Tender Fee | 0 |
| EMD | 4750 |
| Tender Value | - |
| Place | IIT Kanpur |
| Link |
View Original Tender Notice
https://eprocure.gov.in/eprocure/app?page=FrontEndTenderDetailsExternal&service=page&tnid=918378 |
| Start Date | August 18, 2025 23:30 |
| End Date |
Expired
27/08/2025
Expired 415 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Sitc of 2 x4 tr air cooled floor standing tower type split air conditioners with accessories at kd server room of iit kanpur
Sitc of 2 x4 tr air cooled floor standing tower type split air conditioners with accessories at kd server room of iit kanpur
Read moreRepair maint of lift fire hydrant fire alarm system fire pumps and connected em eqpts conventional earthings chemical earthing lightning arrestor dg set amf panel and panel and another connected em eqpts at kalina hq mao 121 hf airport 765 su santacr
Rrepair maint of lift fire hydrant fire alarm system fire pumps and connected em eqpts conventional earthings chemical earthing lightning arrestor dg set amf panel and panel and another connected em eqpts at kalina hq mao 121 hf airport 765 su santac
Read moreSupply and fitment of pressure vessel,supply and fitment of fresh water hydrophore pump,supply and fitment of automatic control panel cum motor er,supply and fitment of pressure switch,supply and fitment of safety relief valve,supply and fitment of pressure gauge,supply and fitment of isolation valves,supply and plumbing of piping network,supply and plumbing of piping network,supply and fitment of water tank,installation and commissioning
Supply and fitment of pressure vessel,supply and fitment of fresh water hydrophore pump,supply and fitment of automatic control panel cum motor er,supply and fitment of pressure switch,supply and fitment of safety relief valve,supply and fitment of pressure gauge,supply and fitment of isolation valves,supply and plumbing of piping network,supply and plumbing of piping network,supply and fitment of water tank,installation and commissioning
Read moreSitc of 4.0 kw jockey pump with motor,sitc of automatic fire pump control panel for 4 pumps,sitc of pressure gauge,sitc of ul fm approved pressure switch,refixing, tc of existing air vessel,sitc of double flanged sluice valves pn 16,sitc of swing check nrv pn 16,sitc of cast iron bucket type strainer 80 mm,sitc of gear-operated dual plate nrv 80 mm pn 16,sitc of lockable butterfly valves pn 16,sitc of class-c heavy-duty ms fire hydrant piping,fabrication, installation of structural steel supports,sitc of pressure relief valve with delivery header,sitc of single-headed stainless-steel landing valve,sitc of double-headed stainless-steel landing valve,sitc of stainless-steel branch pipe with gun metal nozzle,sitc of 5x type low expansion foam branch,sitc of nfpa 1964 compliant jet fire nozzle,sitc of rrl fire hose with couplings,sitc of first aid hose reel with 30 m tph,sitc of automatic air release valve 25 mm,sitc of brass ball valve 25 mm,modification extension of existing fh piping,sitc of gi earthing strip
Sitc of 4.0 kw jockey pump with motor,sitc of automatic fire pump control panel for 4 pumps,sitc of pressure gauge,sitc of ul fm approved pressure switch,refixing, tc of existing air vessel,sitc of double flanged sluice valves pn 16,sitc of swing check nrv pn 16,sitc of cast iron bucket type strainer 80 mm,sitc of gear-operated dual plate nrv 80 mm pn 16,sitc of lockable butterfly valves pn 16,sitc of class-c heavy-duty ms fire hydrant piping,fabrication, installation of structural steel supports,sitc of pressure relief valve with delivery header,sitc of single-headed stainless-steel landing valve,sitc of double-headed stainless-steel landing valve,sitc of stainless-steel branch pipe with gun metal nozzle,sitc of 5x type low expansion foam branch,sitc of nfpa 1964 compliant jet fire nozzle,sitc of rrl fire hose with couplings,sitc of first aid hose reel with 30 m tph,sitc of automatic air release valve 25 mm,sitc of brass ball valve 25 mm,modification extension of existing fh piping,sitc of gi earthing strip
Read moreRepairing and maintenance of fire fighting system including pumps valves pipelines and associated works at gh tower building
Repairing and maintenance of fire fighting system including pumps valves pipelines and associated works at gh tower building
Read moreCapital/major overhauling of valves, piping, coal piping, ducts, dampers , gates , expansion joints and ldo/hfo pumps
(210 mw, oem--bhel) at ghtp, lehra mohabbat.
Read moreReplacement of fcu units and associated piping works in 4i section, iit kanpur
As mentioned in the tender document
Read more06 nos. non-clogging submersible pumps along with piping network, allied panel and accessories
Read more
Sitc of various valves and associated works at iwd central ac plant, iit kanpur
As per tender document
Read moreRepair/maint of fire fighting pipe line,fire hydrant valves and connected items under age(i) af manauri
Repair/maint of fire fighting pipe line,fire hydrant valves and connected items under age(i) af manauri
Read moreof your Industry type